Download Print this page
Sylvania SOCVT-500 / SOCVT-1000 / SOCVT-1500 / SOCVT-2000 Instruction Manual
Sylvania SOCVT-500 / SOCVT-1000 / SOCVT-1500 / SOCVT-2000 Instruction Manual

Sylvania SOCVT-500 / SOCVT-1000 / SOCVT-1500 / SOCVT-2000 Instruction Manual

Convection heater with buit-in thermostat

Advertisement

Quick Links

ConveCtion heater with built-in thermostat
Model: SOCVT-500 / SOCVT-1000 / SOCVT-1500 / SOCVT-2000
imPortant
Please note: when you oPen the Carton Carefully CheCk
the unit and make sure there is no damage. if you have any
Problems with the unit, with how the various funCtions
work, damaged or missing Parts Please Call 1-800-459-4409
(9 am to 5 Pm est) immediately for serviCe.
note: do not return unit to the store before Calling the toll
free number. do not disPose of your Cartons until you are
ComPletely satisfied with your new ConveCtor heater.
INSTRUCTION MANUAL
attention: Find a location for the convection heater that is protected from
direct sunlight.

IMPORTANT SAFETY INSTRUCTIONS

warning: the heater must be installed by a Certified
eleCtriCian and in aCCordanCe with all loCal and national
eleCtriCal Codes.
this ConveCtion heater must be used in ConjunCtion with a
wall switCh or wall thermostat.
this unit reQuires 240v hard wiring.
when using eleCtriCal aPPlianCes, basiC PreCautions should
always be followed to reduCe the risk of fire, eleCtriC shoCk,
and injury to Persons, inCluding the following:
1) read all instructions carefully before using the heater.
2) this heater is hot when in use. to avoid burns, do not let bare skin touch
hot surfaces. if provided, use handles when moving this heater. keep
combustible materials such as furniture, pillows, bedding, papers, clothing
and curtains at least 3 feet (0.9 m) away from front, sides and rear of the
heater.
3) extreme caution is necessary when any heater is used by or near
children or individuals with disabilities and whenever the heater is left
operating and unattended.
4) do not operate the heater if the heater malfunctions, has been dropped
or damaged in any manner. disconnect power at service panel and have
heater inspected by a qualified electrician before use.
5) do not use outdoors.
6) this heater is not intended for use in bathrooms, laundry areas or in wet
or moist indoor locations. never place the heater where it may fall into a
bathtub or other water containers.
7) to disconnect the heater, turn controls to off.
8) do not insert or allow foreign objects to enter any ventilation or exhaust
openings as this may cause an electric shock, fire or may damage the
heater. do not use on soft surfaces, such as a bed where openings may
become blocked.
9) to prevent possible fire, do not block air intakes or exhaust in any
manner.
10) heaters may have hot and sparking parts inside. do not use it in areas
where gasoline, paint or flammable liquids are used or stored.
11) use this heater only as described in this manual. any other use not
recommended by the manufacturer may cause fire, electric shock or
injury to persons.
SAVE THESE INSTRUCTIONS FOR FUTURE USE.

GENERAL INFORMATION

This convection heater is intended for permanent wall-mounting with the
provided brackets.
The heater has a thermal cut-off protection. If the thermal cut-off protection trips,
switch off the power. The unit should reset automatically after 10 minutes. If the
thermal cut-off protection trips again, determine the reason for overheating.

SPECIFICATIONS

eleCtriCal rating
model
VOLTS
SOCVT-500
240
SOCVT-1000
240
SOCVT-1500
240
SOCVT-2000
240
PARTS LIST
Mounting bracket ...........................................................................................................1
Screws ..............................................................................................................................4
Wall Anchor .....................................................................................................................4
INSTALLATION
Tools required:
Electric drill
Phillips (cross-head) screwdriver
Tape measure
Choose a suitable location for mounting the convector. The location shall have
enough space and clearance as illustrated in Fig. 1.
1
ProduCt dimensions
WATTS
HEIGHT (cm) WIDTH (cm) DEPTH (cm)
500
33.1
44.6
1000
40.5
53.7
1500
44.3
58.1
2000
44.3
72.6
9.2
11.2
11.2
11.2

Advertisement

loading

Summary of Contents for Sylvania SOCVT-500 / SOCVT-1000 / SOCVT-1500 / SOCVT-2000

  • Page 1: General Information

    ConveCtion heater with built-in thermostat 4) do not operate the heater if the heater malfunctions, has been dropped Model: SOCVT-500 / SOCVT-1000 / SOCVT-1500 / SOCVT-2000 or damaged in any manner. disconnect power at service panel and have heater inspected by a qualified electrician before use.
  • Page 2: Electrical Wiring

    ELECTRICAL WIRING WIDTH OF CONVECTOR warning: this ConveCtion heater is to be used on a 240 vaC Power suPPly and grounded outlets. BLACK (L) THERMAL CUT-OFF PROTECTION 6 in 6 in (15.3 cm) (15.3 cm) Minimum Minimum clearance to clearance to adjacent adjacent surface...
  • Page 3 WARRANTY MAINTENANCE The heating element is guaranteed for 10 years and all other components are warning: to reduCe the risk of fire or eleCtriC shoCk, always guaranteed for one year from the date of purchase. If the unit should fail to operate switCh off the unit and wait 10 minutes to allow it to Cool correctly, call customer service at 1-800-459-4409 EST.

This manual is also suitable for:

Socvt-500Socvt-1500Socvt-2000