High voltage power supply

Advertisement

User Manual
Power Supply DCP-1500-05
Generalvertretung Deutschland:
TESTEC Elektronik GmbH
Westerbachstr. 58
60489 Frankfurt am Main
Telefon: +49 (0)69 943335 0
Telefax: +49 (0)69 943335 55
e-mail: info@testec.de
Internet: www.testec.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DCP-1500-05 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Finero DCP-1500-05

  • Page 1 User Manual Power Supply DCP-1500-05 Generalvertretung Deutschland: TESTEC Elektronik GmbH Westerbachstr. 58 60489 Frankfurt am Main Telefon: +49 (0)69 943335 0 Telefax: +49 (0)69 943335 55 e-mail: info@testec.de Internet: www.testec.de...
  • Page 2: Table Of Contents

    8.3 Power indicator is lit but the display is not ......................16 8.4 Indicators are lit but buttons don't function ......................16 Tel. +358-5-7522 200 Finero Oy – The Quality Control Company Haltonintie 5, FIN-47400 KAUSALA, FINLAND Fax +358-5-3638 326 www.qacontrol.com...
  • Page 3: Fst-Dcp-1500-05 High Voltage Power Supply

    Parts subject to wear, such as test probes and leads, are not covered by this product warranty, except where they are deemed to have a manufacturing defect within 60 days of the original shipment of the Finero product. Tel. +358-5-7522 200 Finero Oy –...
  • Page 4 We are confident that this equipment will support your endeavors to keep up the good quality of your production. If you have any comments about Finero products, software or services I would like to hear of them. Yours truly,...
  • Page 5 Although Finero packages the equipment with utmost care you should check the package regarding any delivery damages. If the equipment is damaged you should contact your insur- ance company directly and inform Finero as well about the matter. Please include photos if possible.
  • Page 6: Technical Information

    FST-series tester (where RS-232 or IEE488 or USB-board are), then are possible control this device via computer. Tel. +358-5-7522 200 Finero Oy – The Quality Control Company Haltonintie 5, FIN-47400 KAUSALA, FINLAND Fax +358-5-3638 326 www.qacontrol.com...
  • Page 7: General

    Device's activity can deviate to some degree in this instruction from the said resulting customized or other changes. Tel. +358-5-7522 200 Finero Oy – The Quality Control Company Haltonintie 5, FIN-47400 KAUSALA, FINLAND Fax +358-5-3638 326 www.qacontrol.com...
  • Page 8: Accessories

    UserManual FST-DCP-1500-05 HighVoltagePowerSupply 100122EN ver1.doc 7/27 ------------------------------------------------------------------ 2.6 Accessories There are available different accessories, systems and calibrators for test device. Tel. +358-5-7522 200 Finero Oy – The Quality Control Company Haltonintie 5, FIN-47400 KAUSALA, FINLAND Fax +358-5-3638 326 www.qacontrol.com sales@qacontrol.com...
  • Page 9: Safety Precautions

    For manual tests we recommend special test heads having heads protected if not in use or use of a special test chamber. Tel. +358-5-7522 200 Finero Oy – The Quality Control Company Haltonintie 5, FIN-47400 KAUSALA, FINLAND Fax +358-5-3638 326 www.qacontrol.com...
  • Page 10: Installation

    19” rack. Care must be taken of the air circulation in the rack in order to avoid temperature rise above +35°C. Here are some examples of how build the support for rack installation. Tel. +358-5-7522 200 Finero Oy – The Quality Control Company Haltonintie 5, FIN-47400 KAUSALA, FINLAND Fax +358-5-3638 326 www.qacontrol.com...
  • Page 11: High Voltage Connectors

    - Connect the control and high voltage cables to the Tester. - Plug the mains cord to the Power Supply. - Plug the mains cord to a mains outlet. Tel. +358-5-7522 200 Finero Oy – The Quality Control Company Haltonintie 5, FIN-47400 KAUSALA, FINLAND Fax +358-5-3638 326 www.qacontrol.com...
  • Page 12: Manual Operation

    Test voltage switched ON with “Start” –button and switched OFF with “Stop” –button. Also there are selector wheel and “Enter” –button for control menu uses. Tel. +358-5-7522 200 Finero Oy – The Quality Control Company Haltonintie 5, FIN-47400 KAUSALA, FINLAND Fax +358-5-3638 326 www.qacontrol.com...
  • Page 13: Control Menu And Commands

    “Start” -button. The measurement time recommended at least 1 second. The leakage current and other information can see in display: Tel. +358-5-7522 200 Finero Oy – The Quality Control Company Haltonintie 5, FIN-47400 KAUSALA, FINLAND Fax +358-5-3638 326 www.qacontrol.com...
  • Page 14: Error Displays

    INTERRUPTED Test is stopped by user. SAFETY CIRCUIT OPEN Tester safety circuit is open. Tel. +358-5-7522 200 Finero Oy – The Quality Control Company Haltonintie 5, FIN-47400 KAUSALA, FINLAND Fax +358-5-3638 326 www.qacontrol.com sales@qacontrol.com...
  • Page 15: Operation With Computer

    All operations are controlled by the computer using commands or easier by using a specific application program Finero Safetest. The command lists for computer operation mode are appendix of this manual. The control board RS-232 or IEE488 or USB are accessory and its must be ordered separately.
  • Page 16: Remote Control And Logic Operation

    “Stop” signal disconnects the test voltage. The connector has inputs for the safety circuit, if circuit are open high voltage are not con- nected. Tel. +358-5-7522 200 Finero Oy – The Quality Control Company Haltonintie 5, FIN-47400 KAUSALA, FINLAND Fax +358-5-3638 326 www.qacontrol.com...
  • Page 17: Malfunctions

    FU1 and FU2. 8.4 Indicators are lit but buttons don't function Check the safety circuit. Check set values in “Setting” menu. Tel. +358-5-7522 200 Finero Oy – The Quality Control Company Haltonintie 5, FIN-47400 KAUSALA, FINLAND Fax +358-5-3638 326 www.qacontrol.com sales@qacontrol.com...
  • Page 18 Check fuses F1 in external control board. Board is inside tester in back panel. If the above remedies do not help, contact the Tester service. Tel. +358-5-7522 200 Finero Oy – The Quality Control Company Haltonintie 5, FIN-47400 KAUSALA, FINLAND Fax +358-5-3638 326 www.qacontrol.com...
  • Page 19 The warranty period starts on the original shipment date of the product or test system. Our product and test system warranties guarantee that our products will be free from defects in material and workmanship and we will repair or replace any such Finero product or test system we find to be defective.
  • Page 20 UserManual FST-DCP-1500-05 HighVoltagePowerSupply 100122EN ver1.doc 19/27 ------------------------------------------------------------------ FINERO SHALL NOT BE LIABLE FOR ANY EXPENSES, CLAIMS, OR SUITS ARISING OUT OF OR RELATING TO ANY OF THE FOREGOING. Due to continuous development of the products warranty does not include updating of features.
  • Page 21: Command List

    HIGH VOLTAGE POWER FST-DCP-1500-05 COMMAND LIST NOTICE! IF YOU HAVE ORDERED A COMPUTER INTERFACE WITH YOUR FST-EQUIPMENT THIS ANNEX RELEVANT PROGRAMMING Tel. +358-5-7522 200 Finero Oy – The Quality Control Company Haltonintie 5, FIN-47400 KAUSALA, FINLAND Fax +358-5-3638 326 www.qacontrol.com sales@qacontrol.com...
  • Page 22 External controls output 1 and 2 status External control input 1 and 2 status CAL? Tester testing/setting date VER? Tester version IDN? Tester identify code Tel. +358-5-7522 200 Finero Oy – The Quality Control Company Haltonintie 5, FIN-47400 KAUSALA, FINLAND Fax +358-5-3638 326 www.qacontrol.com sales@qacontrol.com...
  • Page 23 (increase are controlled) and unconnected to direct to 0. 2=both are controlled. RLENgth mm Test voltage increase/decrease time (0)4…30 seconds. mm=time Tel. +358-5-7522 200 Finero Oy – The Quality Control Company Haltonintie 5, FIN-47400 KAUSALA, FINLAND Fax +358-5-3638 326 www.qacontrol.com sales@qacontrol.com...
  • Page 24 Stops testing and set Fail indicator on and buzzer ringing about 1 seconds. Used for software fail- alarm. Example: ALAR:ON ALARm:OFF Tester Fail indicator off Example: ALAR:OFF Tel. +358-5-7522 200 Finero Oy – The Quality Control Company Haltonintie 5, FIN-47400 KAUSALA, FINLAND Fax +358-5-3638 326 www.qacontrol.com sales@qacontrol.com...
  • Page 25 RES? Test results inquiry Test stop CURR? Test voltage, return answer in real voltage in test. (0…1100) Example: Tel. +358-5-7522 200 Finero Oy – The Quality Control Company Haltonintie 5, FIN-47400 KAUSALA, FINLAND Fax +358-5-3638 326 www.qacontrol.com sales@qacontrol.com...
  • Page 26 Status byte 2 Value Meaning Resetting 20s timeout ON/OFF 750W power limit ON/OFF Low test voltage ON/OFF Current limit fail ON/OFF Tel. +358-5-7522 200 Finero Oy – The Quality Control Company Haltonintie 5, FIN-47400 KAUSALA, FINLAND Fax +358-5-3638 326 www.qacontrol.com sales@qacontrol.com...
  • Page 27 Output 2 status (0=off, 1=on) External control inputs status. Return answer two numbers : aa Input 1 status (0=off, 1=on) Tel. +358-5-7522 200 Finero Oy – The Quality Control Company Haltonintie 5, FIN-47400 KAUSALA, FINLAND Fax +358-5-3638 326 www.qacontrol.com sales@qacontrol.com...
  • Page 28 MM-4184v1/v1.0 HV-4213v0/v1.0 4074v4/v2.0 IDN? Tester identify code. Return answer from tester free setting code, maximum 20 character. Finero are setting tester type and serial number. Example: DCP-1500 sno: 647307 Tel. +358-5-7522 200 Finero Oy – The Quality Control Company Haltonintie 5, FIN-47400 KAUSALA, FINLAND Fax +358-5-3638 326 www.qacontrol.com...