Advertisement

Quick Links

Operators & Service
Manual
DN3601C
Version 3.0C
TELEX PRO AUDIO GROUP
Klark Teknik Building
Walter Nash Road, Kidderminster
Worcestershire DY11 7HJ
England
Tel: (01562)741515 Fax: (01562)745371

Advertisement

Table of Contents
loading

Summary of Contents for Telex Pro Audio Group DN3601C

  • Page 1 Operators & Service Manual DN3601C Version 3.0C TELEX PRO AUDIO GROUP Klark Teknik Building Walter Nash Road, Kidderminster Worcestershire DY11 7HJ England Tel: (01562)741515 Fax: (01562)745371...
  • Page 2: Table Of Contents

    CONTENTS DECLARATION OF CONFORMITY INTRODUCTION INSTALLATION INSTRUMENT FAMILIARISATION MASTER/SLAVE OPERATION REFERENCE SECTION: DETAILS OF OPERATION DEFAULT/START UP FADER ADJUSTMENT GAIN ADJUSTMENT CURVE/FADER MORE EQ A : B : LINK UTILITIES BYPASS AND RESET MORE EQ MENU AND DISPLAY FILTERS A : B IN/OUT EXIT FILTER ADJUST...
  • Page 3 PARTIAL EXIT MORE... MENU SLAVES STAND ALONE SLAVES 1 TO 64 MIDI CHAN INV LCD EXIT TECHNICAL SPECIFICATION MENU STRUCTURE SERVICE INFORMATION: FUSE SPECIFICATION MIDI CONNECTIONS SCHEMATIC DIAGRAMS...
  • Page 4: Declaration Of Conformity

    DECLARATION OF CONFORMITY The Directive Covered by this Conformity 89/336/EEC Electromagnetic Compatibility Directive, amended by 92/31/EEC & 93/68/EEC. 73/23/EEC Low Voltage Directive, amended by 93/68/EEC. The Products Covered by this Declaration Equipment Type Product Name Variants Graphic Equaliser DN300 DN360, DN301, DN332 Preset Equaliser DN320 DN330...
  • Page 5 Attention! Cables: This product should only be used with high quality, screened twisted pair audio cables, terminated with metal bodied 3-pin XLR connectors. The cable should be connected to pin 1. Any other cable type or configuration for the audio signals may result in degraded performance due to electromagnetic interference.
  • Page 7 THANK YOU FOR USING THIS KLARK TEKNIK PRODUCT To obtain maximum performance from this precision electronic product, please study these instructions carefully. Installation and operating the DN3601 is not complicated, but the flexibility provided by its operating features merits familiarisation with it's controls and connections. This unit has been prepared to comply with the power requirements that exist in your location.
  • Page 8 After you have unpacked the unit Save all the packing materials - they will prove valuable should it become necessary to transport or ship this product. Please inspect this unit carefully for any signs of damage incurred during transportation. It has undergone stringent quality control inspection and tests prior to packing and left the factory in perfect condition.
  • Page 9: Introduction

    INTRODUCTION Designed to meet and exceed the needs of the recording, broadcast, installation and live sound industries, the Klark Teknik DN 3601 Programmable Slave Graphic Equaliser is an extremely high quality, digitally controlled, two-channel, third-octave equaliser that offers state-of-the-art audio performance in a remote controlable, tamper-proof, cost effective package.
  • Page 10: Installation

    Installation The inputs and outputs are fully balanced on XLR connectors and are wired conventionally with pin 1 as ground. Because the system is fully floating, either pin 2 or pin 3 can be designated as hot so long as the same protocol is adhered to for both the input and the output connectors. The DN3601 is designed for use in both fixed and mobile installations where it can be mounted in a conventional 19 inch rack occupying just 2U of height.
  • Page 11: Instrument Familiarisation

    Instrument Familiarisation Front panel functions NUMERIC WINDOW: Displays the address number of the Slave and flashes on and off when the unit is being addressed by an external controler, such as a DN3600. METERS: Separate 10-segment bargraph level meters monitor the signal level in channels A and B over the range -12dB to +15dB.
  • Page 12: Master/Slave Operation

    MASTER/SLAVE OPERATION The Klark Teknik Pro MIDI Master/Slave system allows up to 65 DN3601 and DN3600 units to be operated, either individually or together, from the front panel of a single DN3600 or a siutably equiped computer. The system is simple to connect, simple to operate and protects itself from the dangers of unreliable power supply and damaged connections.
  • Page 13 Any DN3600 in the loop can be designated as the Master by entering the Slaves sub menu (press Utilities, More..., Slaves on the DN3600). The other DN3601 and DN3600 units in the loop will automatically configure themselves as slaves, with the first being number 1, the second being number 2 and so on.
  • Page 14: Details Of Operation

    DETAILS OF OPERATION Being a description of the features and functions accessible via a DN3600 master unit with version 2.0 software. Initial, Default Display Soft key options: More EQ A : B : Link Utilities Bypass Fader adjustment The ‘Virtual’ Graphic Equaliser faders are selected either by pressing the appropriate frequency key or by rotation of the FREQ rotary control.
  • Page 15: More Eq

    More EQ Soft key 1 is accompanied by the text More EQ. Pressing this key selects the More EQ menu and the Filter Adjust display. See below. A : B : Link Soft key 2 is accompanied by the text A : B : Link. Pressing this key toggles between addressing channels A and B.
  • Page 16: More Eq Menu And Display

    More EQ Menu and Display. Accessed by pressing the More EQ key from the Start-up menu. Soft key options: Filters A : B In/Out Exit More EQ Display In More EQ mode, the display shows the frequency response curve calculated from the Notch filter and High Pass and Low Pass filter settings.
  • Page 17: Filter Adjust

    Filter Adjust Menu and Display. Access by pressing the More EQ key followed by the Filters key. Soft key options: Notch 1 Notch 2 Back Display In Filter adjust mode, the display shows the frequency response curve calculated from the Notch filter and High Pass and Low Pass filter settings.
  • Page 18: Utilities Menu

    Utilities menu. Accessed by pressing the Utilities key from the Start-up menu. Soft key options: Auto/Q Memory More. . . Exit Auto/Q Soft key 1 is accompanied by the text Auto/Q. When pressed, this key selects the Auto/Q menu. See below.
  • Page 19 Auto/Q menu. Accessed by pressing the Utilities key followed by the Auto/Q key. Soft key options: Auto Gain Auto EQ 'Q' type Exit Auto Gain Soft key 1 is accompanied by the text Auto Gain. When pressed, this key toggles the Auto Gain function on or off.
  • Page 20: Partial

    Memory/Lockout menu Accessed by pressing the Utilities key followed by the Memory key. Soft key options: Recall Save Lock Exit Recall Soft key 1 is accompanied by the text Recall. This key allows any of the 66 named memories to be recalled.
  • Page 21: More

    Full Full lock prevents access to all controls. After Full Lock has been set, the only action possible is to press the Unlock key and type in a password. If the correct password is typed in, the Full Lock is defeated.
  • Page 22: Slaves 1 To 64

    Slaves 1 to 64 The Master/Slave mode of operation. Select a single slave device to address. When a slave is selected, all controls and adjustments affect that slave only. There are no changes to the local, master DN3600 unit. The DN3600 must be returned to STAND ALONE mode in order to control itself. The procedure may be aborted at any time by pressing the Exit key.
  • Page 23 DN3601 TECHNICAL SPECIFICATION INPUTS Type Balanced (electronically) Impedence (ohm) Balanced Unbalanced Max. level +22dBu OUTPUTS Type Balanced (electronically) Min. load impedence 600ohm Source impedence 50ohm Max. level +22dB into >2kohms PERFORMANCE Frequency response /EQ flat +/-0.5dB (20Hz to 20kHz) Distortion @ +4dBm <0.02% @ 1kHz Equivalent input noise (20Hz to 20kHz unweighted)
  • Page 24: Exit

    DN3600 SOFTWARE V2.0 MENU STRUCTURE MORE EQ A : B : LINK UTILITIES BYPASS FILTERS A : B IN/OUT EXIT NOTCH 1 NOTCH 2 BACK AUTO/Q MEMORY MORE... BACK AUTO GAIN MIDI CHAN AUTO EQ SLAVES Q TYPE INV LCD EXIT EXIT RECALL...
  • Page 26: Service Information

    Service Information...
  • Page 27: Midi Connections

    SERVICE INFORMATION Caution: These servicing instructions are for use by qualified personnel only. To reduce the risk of electric shock, do not perform any servicing other than that contained in the Operating Instructions unless you are qualified to do so. Refer all servicing to qualified service personnel. Klark Teknik PLC accepts no liability for damage or injury arising from incorrect servicing.

Table of Contents