Download Print this page

Ives Offset Intermediate Pivot 7212/12V Installation Instructions page 2

3/4” offset intermediate pivot

Advertisement

!
It is very important for installer to verify that intermediate pivot point lines up with
center line of top and bottom pivot points before final installation. Both door and
frame pivot leafs located from face of door. Intermediate pivot should be evenly
spaced between top and bottom pivots. Heel edge of door must be beveled 1/8" in 2".
Frame Leaf
Face of door
1/2"
13 mm
C L
3/4"
19 mm
13103-00
NOTE
Reference line
5/16"
8 mm
5/16"
8 mm
Right hand installation shown;
left hand opposite
C L
5/16"
8 mm
5/16"
8 mm
Door Leaf
1/2"
13 mm
C L
3/4"
19 mm
Face
of door
13103 Rev. 4