GENERAL INFORMATION The Alliance Heated Pellet / Plate Dispensers is designed specifically for use with a wide variety of 9” plastic and stainless steel pellets and plates. Unit No. DALPH1022 No. of Stacks Capacity per Stack 43 - 50 Total Capacity 86 –...
2. The receiver should sign the packing slip “refused merchandise due to damage” when receiving partial shipment. 3. Contact an Alliance customer service representative and alert them to the situation. B. Concealed Damage – When damaged merchandise can not be externally detected.
C. If a spring adjustment is required, proceed as follows. Lift elevating mechanism assembly up and out of the stainless steel cabinet. Set it on the floor. Disconnect but do not remove any unnecessary springs from the elevator carrier and replace mechanism back into the heater. D.
WARNING Unit must not be run continually and must be turned off between meals. Otherwise, unit may shut off automatically requiring service reset. Warranty may be voided if used improperly. START-UP A. Overview These units are designed to heat plastic or stainless steel pellets or plates. The fan motor, heating element, and power indicator light will come on once the unit is turned on.
CAUTION Operators should always wear gloves or use pellet / plate lifters when dispensing. After the unit is turned off, the pellets / plates remaining inside the unit will remain hot for some time. CLEANING CAUTION Make sure unit is unplugged and cool before attempting to clean. The following procedures should be followed during the regular cleaning routine on all of the pellet heaters.
TROUBLESHOOTING CAUTION Thermostat adjustment should only be made only by qualified personnel. Complaint Problem Solution A. Unit does not heat but 1. Open high limit thermostat. 1A. Push reset button. fan operates. 1B. Check for causes before restarting equipment. 1C. Replace hi-limit thermostat. 2.
PARTS LIST / DIAGRAMS DALPH1022 ITEM NO. DESCRIPTION PART NO. QTY. Lid Assembly – End 015A00101 Lid Assembly – Center 015A00102 Hinge 50681-01 Switch Guard 50907-01 Lid Handle 052P00108 Push / Pull Handle 015A00301 Cord - 10 ft. Length Plug - NEMA 6-20 Straight Blade...
PREVENTIVE MAINTENANCE Casters 1. Check casters for freedom of movement and proper brake operation. 2. Maintain casters free of debris. (mop strings, paper, plastic, hair nets, etc…) 3. Clean or replace as required. Cord and Plug 1. Inspect plug blades for distortion and replace if any blades are missing, bent or broken.
(1) year of the date of shipment from the ALLIANCE factory. Repair or replacement will be at the option of ALLIANCE and will be f.o.b. the ALLIANCE factory. Warranty includes ninety (90) days for labor from date of shipment.
Alliance shall not be liable for any damage arising from the defective delivery or delay caused thereby. When expressly authorized by Alliance in writing, unused products may be returned to Alliance subject to service handling, restocking and rebuilding charges to “as new”...
Need help?
Do you have a question about the DALPH1022 and is the answer not in the manual?
Questions and answers