Disconnect the lead wires from the switches and check for the continuity of the switches, connecting an Ohm-Meter
to its terminals.
SWITCHES
SWITCHES
SWITCHES
SWITCHES
SWITCHES
(See Figure 1 on page 1)
(See Figure 1 on page 1)
(See Figure 1 on page 1)
(See Figure 1 on page 1)
(See Figure 1 on page 1)
Primary Interlock
Door Sensing
Interlock Monitor
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
:
After checking the switches, make sure that the interlock monitor switch is properly connected according
to the CIRCUIT DIAGRAM on page 3.
CHECKOUT PROCEDURE
CHECKOUT PROCEDURE
CHECKOUT PROCEDURE
CHECKOUT PROCEDURE
CHECKOUT PROCEDURE
Measure the resistance between terminals of
FPC connector after removing it from S101.
(Figure 9).
NOTE
NOTE
NOTE
NOTE
NOTE
- When reconnecting the FPC connector, make
sure the holes on the connector are properly
inserted in hooks of the plastic fastener in S101.
MA
MATRIX CIRCUIT FOR
MA
MA
MA
TRIX CIRCUIT FOR
TRIX CIRCUIT FOR
TRIX CIRCUIT FOR
TRIX CIRCUIT FOR
TOUCH KEY BOARD
TOUCH KEY BOARD
TOUCH KEY BOARD
TOUCH KEY BOARD
TOUCH KEY BOARD
FPC CONNECTOR
FPC CONNECTOR
FPC CONNECTOR
FPC CONNECTOR
FPC CONNECTOR
POWER
5
LEVEL
TOTAL
QUICK
DEFROST
ON
QUICK
DEFROST
PIZZA
S TAR T
FRESH
CLOCK
VEGETABLE
CHECKOUT PROCEDURE FOR SWITCHES
CHECKOUT PROCEDURE FOR SWITCHES
CHECKOUT PROCEDURE FOR SWITCHES
CHECKOUT PROCEDURE FOR SWITCHES
CHECKOUT PROCEDURE FOR SWITCHES
CHECKOUT PROCEDURES
CHECKOUT PROCEDURES
CHECKOUT PROCEDURES
CHECKOUT PROCEDURES
CHECKOUT PROCEDURES
Terminals "COM" and "NO"
Terminals "COM" and "NC"
SOUP /
MORE +
BEVERAGE
LESS -
POTATO
FROZEN
KITCHEN
ENTREE
TIMER
ADD
FROZEN
30 SEC
VEGETABLE
CUSTOM
POPCORN
PROGRAMS
- 6 -
RESUL
RESUL
RESUL
RESUL
RESULT T T T T
When
touched
Resistance
value
Less than
1K Ohms
When checking "START" key, connect
Ohm-Meter as illustration below.
Ohm-Meter
Ohm-Meter
Ohm-Meter
Ohm-Meter
Ohm-Meter
TERMINALS OF FPC CONNECTOR
TERMINALS OF FPC CONNECTOR
TERMINALS OF FPC CONNECTOR
TERMINALS OF FPC CONNECTOR
TERMINALS OF FPC CONNECTOR
DOOR OPEN
DOOR OPEN
DOOR OPEN
DOOR OPEN
DOOR OPEN
When not
touched
More than
1 MEG Ohms
Figure 9
Figure 9
Figure 9
Figure 9
Figure 9
DOOR CLOSED
DOOR CLOSED
DOOR CLOSED
DOOR CLOSED
DOOR CLOSED