  • Page 1 User Guide EH1230 EH1230 8500BTU/h Class A Portable Air Conditioner • 2 cooling and 2 fan speed settings • 24-hour timer • Built-in Dehumidification function • Adjustable louvre • Easy to install - no external unit required. Page 1...
  • Page 2: Installation

    IMPORTANT Installer and Users please note: These instructions should be read carefully and left with the user of the product for future reference. INSTALLATION. Install the EH1230 on floor approximately 36cm (14") from a wall. Ensure that the air inlets (on the sides) and the air outlets (on the top) cannot be covered.
  • Page 3 User Guide EH1230 foam strip provided to block the rest of the window opening. This is essential for efficient cooling. The correct installation of the exhaust tube is shown below: If the exhaust tube needs bending, do not bend too sharply, or more than is required.
  • Page 4 User Guide EH1230 case). Do not install close to a source of heat. The EH1230 is not suitable if the ambient temperature is below 18°C or above 35°C. Installing the carbon filter: 1. Remove the filter frame from the unit.
  • Page 5: Operation

    User Guide EH1230 OPERATION This appliance is not intended for use by persons (including children) with reduced physical, sensory mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Page 6 User Guide EH1230 automatically. The fan speed indicators (13) or (14) will indicate whether slow of fast fan speed is in operation. If the desired room temperature is above the ambient temperature then no cooling will take place. The fan will run at its slow speed.
  • Page 7 Collect the water in the tray and pour away. Dehumidifying: The EH1230 can be used for dehumidification provided that the ambient temperature is above 19°C. Keep the windows and doors closed to increase the efficiency of the dehumidifying operation.
  • Page 8: Using The Remote Control

    User Guide EH1230 Timer The built-in timer can be used to set the unit to run for a certain length of time before automatically switching off. Press the timer button (2) and set the number of hours of operation using the + and - buttons. The maximum setting is 12 hours.
  • Page 9 User Guide EH1230 Maintenance Disconnect the unit from the mains supply before carrying out any maintenance. Cleaning: Clean the outer casing with a damp cloth with a little mild detergent such as washing-up liquid. Do not use abrasives, or solvents other than water.
  • Page 10: Fault Finding

    User Guide EH1230 Fault Finding. • No operation (no LEDs lit on control panel) Press ON/OFF switch to make sure the unit is switched on. Check mains supply. Check fuse in mains plug. If the "water full" indicator is flashing - empty the water.
  • Page 11: Technical Specification

    User Guide EH1230 Technical specification Cooling Capacity 8500BTU/h 2.7kW Power Supply 230V ~ 50Hz Power Consumption 920W Operating Current: 4.3A Humidity removal capacity 24 litres/day Airflow: 300m Refrigerant R410a Refrigerant load 290g Fan speeds Timer 1 to 24 hours Working temperature: 18°C to 35°C...
  • Page 12 User Guide EH1230 Service Warranty Prem-i-Air guarantees the product free from defects in materials and workmanship for a period of one year. Should this unit be operated under conditions other than those recommended, at voltages other than the voltage indicated on the unit, or any attempts made to service or modify the unit , then the warranty will be rendered void.