Braemar, Inc. DL700 DL700 DL700 DL700 Operator Manual Caution: U.S. Federal law restricts this device to sale by or on the order of a physician.
Page 2
Braemar Limited Warranty Braemar products are warranted to be free from manufacturing and material defects for a period of one (1) year from the date of shipment from Braemar to the original purchaser. Excluded from this warranty are expendable supply items including, but not limited to, electrodes, leadwires, patient cables and batteries.
DL700. After the ECG data has been recorded, the memory card is removed from the DL700 and inserted in a Flash Card Reader which is part of the Computer Analysis System on which the ECG will finally be analyzed. The Flash memory card used in the DL700 is the same as some PCMCIA memory cards used in laptop computers.
The patient input connector provides a snug and reliable connection for the Serial Number patient electrode leads along with complete color-coding for each lead. Not shown - DL700 is the catalogue number. Test Jacks Three test jacks are provided to verify that a good, reliable signal is being...
3.1 Battery Installation To ensure a full 24 hour recording it is essential to use new batteries before each patient recording. The recommended batteries for the DL700 Holter recorder are two AA alkaline batteries (IEC-LR6). When inserting the batteries, follow the Start Recording procedure in the Operation section while making sure to follow the polarity indication shown on the label in the battery compartment.
DL700 Holter Monitor DL700 Holter Monitor To set the current date, press the top access hole repeatedly to obtain the desired date. 4. Electrode Application g) Press the bottom access hole to select the HOURS. For safe and effective use, it is recommended that application of electrodes be handled by trained medical personnel.
DL700 Holter Monitor DL700 Holter Monitor remove any debris. 5. Operation Connect the color coded snap-on lead wires to the appropriate electrodes before applying the electrodes to the patient. 5.1 Materials Needed g) Once the backing is removed from each electrode, place it firmly on the a) One Flash memory card with a storage capacity of 10 MB or larger.
DL700 Holter Monitor DL700 Holter Monitor e) The green operating LED will start to blink at a steady rate to indicate normal operation. The LED will blink at this rate for up to 15 minutes 5.3 To Stop Recording allowing time to verify that the signal on each channel is acceptable.
6. Maintenance Service And Maintenance The DL700 Holter Recorder requires virtually no maintenance. Ensure that the battery contacts are clean and that the inside of the recorder is free of dust and dirt. The case and the pouch with belt and strap can be cleaned with a lint free towel moistened with mild soap and water.
Problem: Digital clock is blank Solution: Replace clock battery by referring to the Maintenance section in this manual. - Note - The digital clock is independent from the operation of the DL700 and does not affect the recording.
DL700 Holter Monitor DL700 Holter Monitor Problem: Noisy ECG Recording 8. Service Items Solution: Part Number Ensure that all the electrodes are firmly and securely attached to the patient. (Refer to “Electrode Attachment” section). HeartStor card, 16 Mbytes 350-0147-01 Replace the entire lead set. (These leads are frequently broken...
DL700 Holter Monitor DL700 Holter Monitor Appendix A 9. Electrode Placement (7 Lead) Seven color coded leadwires are utilized to create a 3 channel ECG recording. 3 Channel Electrode Placement Chart: White: Channel 1 (-); Place on the right Manubrial border of the Sternum.
DL700 Holter Monitor DL700 Holter Monitor 10. Electrode Placement (5 Lead) Five color coded leadwires are utilized to create a 2 channel ECG recording. 2 Channel Electrode Placement Chart: White: Channel 1 (-); Place on the right Manubrial border of the Sternum.
Page 16
DL700 Holter Monitor Figure 5 5 Lead Electrode Placement Braemar Inc. Phone: 800.328.2719 1285 Corporate Center Drive, Suite 150 Fax: 651.286.8630 Eagan, MN 55121 USA E-Mail: Service@BraemarInc.com Copyright 2006, Braemar Inc. All rights reserved...