Page 2
Room 1806, Hua Bin Building No. 8 Yong An Dong Li Jian Guo Men Wai Ave Chao Yang District Beijing, P.R. China 100022 ® Clear-Com, CellCom/FreeSpeak and the Clear-Com Communications Systems logo are registered trademarks of The Vitec Group plc.
Operation ..........1-2 ECS System Configuration for ICS-22 Panels ....1-2 Front Panel .
Page 4
Bills of Materials ........4-6 ICS-22 Main PCB (Part No. 710470)..... 4-6 ICS-22 VOX PCB (Part No.
Page 5
Installation chapter of this manual. these instructions before operating a (3) Do not install a ICS-22 speaker panel near a heat source such as a radiator, heat register, stove, or other apparatus (including amplifiers) ICS-22 speaker panel. that produces heat. Do not place naked flame sources such as candles on or near a ICS-22 speaker panel.
Page 6
Do not open the product's case. This symbol informs you that important operating and main- tenance instructions are included in the literature accompanying this product. Figure 1: Safety Symbols Vitec Group Communications ICS-22 Speaker Panel Instruction Manual...
It features excellent speech intelligibility, even in high noise levels, and can be customized through its programmable options. In addition, the ICS-22 contains a jack for an optional Clear-Com gooseneck panel microphone and a close-in, voice-operated circuit • The ICS-22 is a (VOX).
The two ICS-22 selectors are mapped onto the ICS-1008 keys starting from the left. Only the leftmost two pairs of keys on the ICS-1008 can be used to program the ICS-22; any other keys on the ICS-1008 will have no effect.
FRONT PANEL The controls, indicators, and connectors on the ICS-22 front panels are • Appropriately setting shown below and are described in the text that follows. the sidetone level decreases confusion, especially in loud environments. Call Waiting Talk/Listen Select Panel Mic...
• The receiving panel can terminate the call by pressing and releasing the answer-back button. • The calling panel can terminate the call. 1 - 4 Vitec Group Communications ICS-22 Speaker Panel Instruction Manual...
Two beeps Label change audio levels. Single beep Monitoring Table 1-1: ICS-22 Tone Alerts Intercom-Level Control This control sets the listen level required on the speaker or headset. It • Note: Forcing the does not affect the program-input level. trimpots past their...
This switch selects the panel/interface label (A or B) for communication. Headset Connector This connector is located on the front panel. All Clear-Com headsets are recommended for use with the ICS-22. The Clear-Com PT-4 Push-to-Talk Microphone or the HS-6 Telephone Handset will also plug into the headset connector.
Clear-Com recommends that the GM-9 (9-in. long) and GM-18 (18-in. • To install a GM-9 or long) plug-in panel microphones be used with the ICS-22. Both are the electret type. The 1/4-in. phone jack on the microphone mates with the GM-18 microphone panel-mic receptacle on the ICS-22’s front panel.
(SA) output of a main panel it can be used as a paging input. Since the level of this input is independently adjustable from the intercom audio volume, it can be used to override the intercom audio. 1 - 8 Vitec Group Communications ICS-22 Speaker Panel Instruction Manual...
400011 for 220 VAC power.) This connection is a better choice if the headset or speaker is mounted in a desktop box, such as a Clear-Com case.The panel can DT-Box, which is not located on a wall.
5. Install the ICS-22 into the USA standard four-gang outlet box. 6. Set listen levels and sidetones (see Figure 1-2 on page 1-8). 7. The speaker panel should now be operating properly. 8. Read the rest of this manual for further information.
INSTALLATION 1. Connect the 14- to 18-VAC power to the two-position terminal strip. Plug the terminal strip onto the P2 as shown in Figure 1-2 on page • The ICS-22 runs on 1-6. 14- to 18-VAC power. 2. Connect the eight-wire, modular RJ-45 connector to J1 as shown in Figure 1-2 on page 1-6.
Hum or buzz in Inductive pickup Relocate the offending system. caused by close unit or wiring. proximity of this speaker panel or connected panels to power lines or transformers. Vitec Group Communications 4 - 1 ICS-22 Speaker Panel Instruction Manual...
Page 22
Rapid clicking noise. 1. Defective wiring or 1. Repair/replace connectors. wiring or connectors. 2. Defective IC1 on 2. Replace IC1. 710533 assembly. 4 - 2 Vitec Group Communications ICS-22 Speaker Panel Instruction Manual...
150 Hz to 15 kHz, ± 3 dB Power Requirements Voltage 30-VDC standard unit; 16- to 18-VAC with 4-Wire Option Module Current 100 mA average Internal Connectors Program Three-position, plug-on screw terminals Vitec Group Communications 5 - 1 ICS-22 Speaker Panel Instruction Manual...
Page 40
ICS-22 1.34 lb. (0.61 kg) Notice About Specifications While Clear-Com makes every attempt to maintain the accuracy of the information contained in its product manuals, that information is subject to change without notice. Performance specifications included in this manual are design-center specifications and are included for customer guidance and to facilitate system installation.
• UHF wireless intercom systems have a limited warranty of three years. • All other Clear-Com and Drake brand systems and products, including beltpacks, have a limited warranty of two years. The warranty starts at the time of the product’s original purchase. The...
Telephone for Europe, Middle East and Africa: +49 40 6688 4040 or +44 1223 815000 Telephone for the Americas and Asia: +1 510 337 6600 Email: vitec.support@AVC.de Once the standard warranty period has expired, the User Support Center will continue to provide telephone support if you have purchased an Extended Warranty.
purchase of an extended warranty extends to five years the warranty of any product offered with a standard two-year warranty. The total warranty period will not extend beyond five years. Note: VGC does not offer warranty extensions on UHF wireless intercom systems, or on any product with a 1-year or 90-day warranty.
Need help?
Do you have a question about the ECLIPSE ICS-22 and is the answer not in the manual?
Questions and answers