Summary of Contents for Clear-Com ECLIPSE ICS-22

  • Page 1 CLEAR-COM ECLIPSE ICS-22 SPEAKER PANEL INSTRUCTION MANUAL...
  • Page 2 Room 1806, Hua Bin Building No. 8 Yong An Dong Li Jian Guo Men Wai Ave Chao Yang District Beijing, P.R. China 100022 ® Clear-Com, CellCom/FreeSpeak and the Clear-Com Communications Systems logo are registered trademarks of The Vitec Group plc.
  • Page 3: Table Of Contents

    Operation ..........1-2 ECS System Configuration for ICS-22 Panels ....1-2 Front Panel .
  • Page 4 Bills of Materials ........4-6 ICS-22 Main PCB (Part No. 710470)..... 4-6 ICS-22 VOX PCB (Part No.
  • Page 5 Installation chapter of this manual. these instructions before operating a (3) Do not install a ICS-22 speaker panel near a heat source such as a radiator, heat register, stove, or other apparatus (including amplifiers) ICS-22 speaker panel. that produces heat. Do not place naked flame sources such as candles on or near a ICS-22 speaker panel.
  • Page 6 Do not open the product's case. This symbol informs you that important operating and main- tenance instructions are included in the literature accompanying this product. Figure 1: Safety Symbols Vitec Group Communications ICS-22 Speaker Panel Instruction Manual...
  • Page 7: Operation

    It features excellent speech intelligibility, even in high noise levels, and can be customized through its programmable options. In addition, the ICS-22 contains a jack for an optional Clear-Com gooseneck panel microphone and a close-in, voice-operated circuit • The ICS-22 is a (VOX).
  • Page 8: Operation

    The two ICS-22 selectors are mapped onto the ICS-1008 keys starting from the left. Only the leftmost two pairs of keys on the ICS-1008 can be used to program the ICS-22; any other keys on the ICS-1008 will have no effect.
  • Page 9: Front Panel

    FRONT PANEL The controls, indicators, and connectors on the ICS-22 front panels are • Appropriately setting shown below and are described in the text that follows. the sidetone level decreases confusion, especially in loud environments. Call Waiting Talk/Listen Select Panel Mic...
  • Page 10: Answer-Back Facility

    • The receiving panel can terminate the call by pressing and releasing the answer-back button. • The calling panel can terminate the call. 1 - 4 Vitec Group Communications ICS-22 Speaker Panel Instruction Manual...
  • Page 11: Answering Another Call From The Answer-Back Stack

    Two beeps Label change audio levels. Single beep Monitoring Table 1-1: ICS-22 Tone Alerts Intercom-Level Control This control sets the listen level required on the speaker or headset. It • Note: Forcing the does not affect the program-input level. trimpots past their...
  • Page 12: Program-Level Control

    This switch selects the panel/interface label (A or B) for communication. Headset Connector This connector is located on the front panel. All Clear-Com headsets are recommended for use with the ICS-22. The Clear-Com PT-4 Push-to-Talk Microphone or the HS-6 Telephone Handset will also plug into the headset connector.
  • Page 13: Panel-Mic Connector

    Clear-Com recommends that the GM-9 (9-in. long) and GM-18 (18-in. • To install a GM-9 or long) plug-in panel microphones be used with the ICS-22. Both are the electret type. The 1/4-in. phone jack on the microphone mates with the GM-18 microphone panel-mic receptacle on the ICS-22’s front panel.
  • Page 14: Call-Alert Tone-Level Control (1)

    (SA) output of a main panel it can be used as a paging input. Since the level of this input is independently adjustable from the intercom audio volume, it can be used to override the intercom audio. 1 - 8 Vitec Group Communications ICS-22 Speaker Panel Instruction Manual...
  • Page 15: Power Connection (5)

    400011 for 220 VAC power.) This connection is a better choice if the headset or speaker is mounted in a desktop box, such as a Clear-Com case.The panel can DT-Box, which is not located on a wall.
  • Page 16 1 - 1 0 Vitec Group Communications ICS-22 Speaker Panel Instruction Manual...
  • Page 17: Quick Start

    5. Install the ICS-22 into the USA standard four-gang outlet box. 6. Set listen levels and sidetones (see Figure 1-2 on page 1-8). 7. The speaker panel should now be operating properly. 8. Read the rest of this manual for further information.
  • Page 18 2 - 2 Vitec Group Communications ICS-22 Speaker Panel Instruction Manual...
  • Page 19: Installation

    INSTALLATION 1. Connect the 14- to 18-VAC power to the two-position terminal strip. Plug the terminal strip onto the P2 as shown in Figure 1-2 on page • The ICS-22 runs on 1-6. 14- to 18-VAC power. 2. Connect the eight-wire, modular RJ-45 connector to J1 as shown in Figure 1-2 on page 1-6.
  • Page 20 3 - 2 Vitec Group Communications ICS-22 Speaker Panel Instruction Manual...
  • Page 21: Maintenance

    Hum or buzz in Inductive pickup Relocate the offending system. caused by close unit or wiring. proximity of this speaker panel or connected panels to power lines or transformers. Vitec Group Communications 4 - 1 ICS-22 Speaker Panel Instruction Manual...
  • Page 22 Rapid clicking noise. 1. Defective wiring or 1. Repair/replace connectors. wiring or connectors. 2. Defective IC1 on 2. Replace IC1. 710533 assembly. 4 - 2 Vitec Group Communications ICS-22 Speaker Panel Instruction Manual...
  • Page 23: Technical Reference

    TECHNICAL REFERENCE Figure 4-1: ICS-22 Block Diagram Vitec Group Communications 4 - 3 ICS-22 Speaker Panel Instruction Manual...
  • Page 24 BLANK PAGE 4 - 4 Vitec Group Communications ICS-22 Speaker Panel Instruction Manual...
  • Page 25 C1 C1 C2 C2 ASSY #710470 P3 P3 P2 P2 P1 P1 Figure 4-2: Main PCB Component Layout (part no. 710470) Vitec Group Communications 4 - 5 ICS-22 Speaker Panel Instruction Manual...
  • Page 26: Bills Of Materials

    BILLS OF MATERIALS ICS-22 Main PCB (Part No. 710470) CAPACITORS Designator Description C8 C47 220 uF Aluminum 35V .01 uF Ceramic Disc 1.4KV 20% 1 22 uF Tantalum 16V 4.7 uF Tantalum 35V 4.7 uF Aluminum NP 50V .047 uF Mylar 100V 5%...
  • Page 27 IC LM384 POWER 4W OP AMP 1 IC11 IC 7805L POS 5V REGLTR D9 D12 D15 D16 Diode BAV70 DUAL DIODE IC1 IC2 IC8 IC 833 DUAL OP AMP Vitec Group Communications 4 - 7 ICS-22 Speaker Panel Instruction Manual...
  • Page 28 Lens LENS, YELLOW, ROUND 1 Speaker 2 1/2 IN. SPKR 16 OHM 3.5W S4 S5 Switch DPDT P.B. Switch DPDT ROCKER PC MNT W/BRCKT Switch DIP SWITCH PIANO 3 Switch SPDT ROCKER 4 - 8 Vitec Group Communications ICS-22 Speaker Panel Instruction Manual...
  • Page 29 Figure 4-3: ICS-22 Schematic (part no. 710470) Vitec Group Communications 4 - 9 ICS-22 Speaker Panel Instruction Manual...
  • Page 30 BLANK PAGE 4 - 1 0 Vitec Group Communications ICS-22 Speaker Panel Instruction Manual...
  • Page 31: Ics-22 Vox Pcb (Part No. 710472)

    Figure 4-4: VOX PCB Component Layout (part no. 710472) ICS-22 VOX PCB (Part No. 710472) CAPACITORS Designator Description 1 uF Aluminum NP 50V 10% 470 pF Ceramic Disc 50V 10% C8 C12 4.7 uF Tantalum 16V C1 C2 C3 .1 uF Monolithic 50V 10% 680 pF Ceramic Disc 50V 10% .022 uF Monolithic 50V 10%...
  • Page 32 Diode 1N5231B ZENER 5.1V .5W 5% Diode 1N4740A ZENER 10V 0.5W 5% MISCELLANEOUS Designator Description Panel Mic Jack PHONE JACK Pot SHAFT FOR PIHER POT BLACK Switch DPDT TOGGLE 4 - 1 2 Vitec Group Communications ICS-22 Speaker Panel Instruction Manual...
  • Page 33 Figure 4-5: VOX Schematic (part no. 710472) Vitec Group Communications 4 - 1 3 ICS-22 Speaker Panel Instruction Manual...
  • Page 34 BLANK PAGE 4 - 1 4 Vitec Group Communications ICS-22 Speaker Panel Instruction Manual...
  • Page 35: Matrix Option Pcb (Part No. 710533)

    10 uF Aluminum 50V .022 uF Monolithic 50V 10% .1 uF Monolithic 100V 10% .0022 uF Monolithic 50V 10% 100 uF Aluminum 35V 2200 uF Aluminum 35V 20% Vitec Group Communications 4 - 1 5 ICS-22 Speaker Panel Instruction Manual...
  • Page 36 INTEGRATED CIRCUITS Designator Description IC LM833N IC 488E RS-422 XCVR MISCELLANEOUS Designator Description Transformer 600CT/600CT Transformer 10K:10K IC MICRO, KB/MR MATRIX OPTION Connector 2 POS HSING, SCRW TRM. 4 - 1 6 Vitec Group Communications ICS-22 Speaker Panel Instruction Manual...
  • Page 37 Figure 4-7: Matrix Option Schematic (part no. 710533) Vitec Group Communications 4 - 1 7 ICS-22 Speaker Panel Instruction Manual...
  • Page 38 BLANK PAGE 4 - 1 8 Vitec Group Communications ICS-22 Speaker Panel Instruction Manual...
  • Page 39: Specifications

    150 Hz to 15 kHz, ± 3 dB Power Requirements Voltage 30-VDC standard unit; 16- to 18-VAC with 4-Wire Option Module Current 100 mA average Internal Connectors Program Three-position, plug-on screw terminals Vitec Group Communications 5 - 1 ICS-22 Speaker Panel Instruction Manual...
  • Page 40 ICS-22 1.34 lb. (0.61 kg) Notice About Specifications While Clear-Com makes every attempt to maintain the accuracy of the information contained in its product manuals, that information is subject to change without notice. Performance specifications included in this manual are design-center specifications and are included for customer guidance and to facilitate system installation.
  • Page 41: Limited Warranty

    • UHF wireless intercom systems have a limited warranty of three years. • All other Clear-Com and Drake brand systems and products, including beltpacks, have a limited warranty of two years. The warranty starts at the time of the product’s original purchase. The...
  • Page 42: Warranty Repairs And Returns

    Telephone for Europe, Middle East and Africa: +49 40 6688 4040 or +44 1223 815000 Telephone for the Americas and Asia: +1 510 337 6600 Email: vitec.support@AVC.de Once the standard warranty period has expired, the User Support Center will continue to provide telephone support if you have purchased an Extended Warranty.
  • Page 43: Liability

    purchase of an extended warranty extends to five years the warranty of any product offered with a standard two-year warranty. The total warranty period will not extend beyond five years. Note: VGC does not offer warranty extensions on UHF wireless intercom systems, or on any product with a 1-year or 90-day warranty.
  • Page 44 Vitec Group Communications Warranty...