3-2-4 Auto Restart (AW
1) The operation mode, wind volume of fan motor and the set temperature right before the blackout are memorized in
EEPROM and so the operation can continue with the previous operation mode, wind volume of fan motor and the set
temperature after the recover of blackout.
3-2-5 Sleep operation mode
1) Enable to sleep operation only when cooling operation.
2) First, 7-SEG LED DISPLAY "SLEEP" while 15 second, Second, 7-SEG LED DISPLAY "8Hr"
And, automatically SET OFF after operated while 8 Hour
3) If sleep operation, setting Temperature rise 1˚C after 1 Hour
4) ON TIMER operation, not operation, ENERGY SAVER operation, not sleep operation.
3-2-6 Air flow blade swing motor operation
1) The Air flow blade swing motor is turned on and off according to Air flow blade swing operation in remocon or panel,
if SET is cooling or Fan operation mode.
2) If the operation mode is "ENERGY SAVER", in case of fan motor being turned off Air flow blade swing motor is
immediately turned off.
3-2-7 LED display indication in case of error detection
ERROR OPERATION
ROOM THERMISTOR
(OPEN or SHORT)
1) Set operation in case of error occurrence.
• Malfunction of each temperature sensor (open, short)
- Error mode display, warning sound.
- The operation status is off.