Advertisement

How to Install the Unit
1
To prevent vibration and noise, make sure the unit
is installed securely and firmly.
2
Install the unit where the sunlight does not shine
directly on the unit.
3
There should be no obstacles, such as a fence and
wall, within 20" from the back of the cabinet
because it will prevent heat radiation of the
condenser.
Restriction of outside air will greatly reduce the
cooling efficiency of the air conditioner.
CAUTION: All side louvers of the cabinet must remain exposed to the outside of the structure.
4
Install the unit a little slanted so the back is slightly lower than the front (about 1/2").
This will force condensed water to flow to the outside.
5
Install the unit with the bottom about 30"~60" above the floor level.
Window Requirements
NOTE: All supporting parts should be secured to firm wood, masonry, or metal.
• This unit is designed for installation in standard double
hung windows with actual opening widths from 26"
to 41".
• The top and bottom window sash must open sufficiently
to allow a clear vertical opening of 18" from the bottom
of the upper sash to the window stool.
Cooled air
26" to 41"
18" min.
Inner sill
Interior wall
26" min.
(Without frame curtain)
12
y y
Fence
Awning
Heat
radiation
A bout
1
/
"
2
Over 20"
Sash
Window
Offset
Sill
Exterior