Raypak Majestic ODSR36A Owners Installation & Operating Instructions
Raypak Majestic ODSR36A Owners Installation & Operating Instructions

Raypak Majestic ODSR36A Owners Installation & Operating Instructions

Outdoor/indoor wood fireplaces

Advertisement

Quick Links

MAJESTIC
OUTDOOR / INDOOR WOOD FIREPLACES
Model: ODSR36A
OWNERS INSTALLATION & OPERATING INSTRUCTIONS.
KEEP THESE INSTRUCTIONS FOR FUTURE REFERANCE.

Advertisement

Table of Contents
loading

Summary of Contents for Raypak Majestic ODSR36A

  • Page 1 MAJESTIC OUTDOOR / INDOOR WOOD FIREPLACES Model: ODSR36A OWNERS INSTALLATION & OPERATING INSTRUCTIONS. KEEP THESE INSTRUCTIONS FOR FUTURE REFERANCE.
  • Page 2 CONTENTS Part 1: Safety Information Part 2: Installation Instructions • Outdoor Installation • Planning Information • Mounting the Fireplace • Framing • Flue Installation • Flue Offset Installation • Positioning, safety Strips, Securing the fireplace • Chase Installation • Clearances •...
  • Page 3: Safety Information

    Check with the building inspector for compliance with local codes; a permit may be required. 3. This appliance must be installed using Raypak approved flue kit and installed as per the Australian standard AS/ANZ 2918 codes This appliance must be flued directly off the appliance and discharged to atmosphere.
  • Page 4: Installation Instructions

    7. The flue should be inspected periodically and cleaned if necessary. 8. DO NOT store wood, flammable liquids or other combustible materials close to the unit. 9. Contact your local fire authority for information on how to handle a chimney fire. Have a clearly understood plan to handle a flue fire, turn air control to the closed position and call the fire brigade.
  • Page 5 exposed above the fireplace housing, this applies for both Indoor and Outdoor installations Note: If this unit is installed outdoors and the flue is to be installed in a chase construction ( see Fig 6 ) or requires a roof penetration ( pergola or veranda ) you must use the Indoor flue kit part number: ODIDSSFLKT Select the location for the appliance.
  • Page 6: Planning Information

    Fig 2 Free standing installation Note: If the fire place is a free standing unit, it must be located a minimum of 3m from the opening of the fire box to combustibles structure. A minimum height of 1.9m measured from the base of the fire box to the flue termination cowl is permitted.
  • Page 7: Flue Installation

    Brick or block work to create the fire place surround. Use only Raypak Outdoor flue kit part number: ODSSFLKT or Raypak Indoor / outdoor flue kit part number: ODIDSSFLKT Determine how the flue will be run, length of run and flue components required to complete the job.
  • Page 8: Offset Installation

    This is accomplished by using 2 x 45 deg offsets elbows. Option 1: Twin skin Raypk Offset kit part number: DSSSOKT Option 2: Triple skin Raypak Offset kit part number: TSSSOKT • Positioning, safety Strips, Securing the fireplace. Slide the fire place into position. Four nailing flanges are incorporated on each corner of the surround.
  • Page 9: Chase Installation

    • Chase Installation A chase is a vertical boxlike structure which encloses the fireplace and flue. Chases are typically built on the outside of the house or free standing with fireplace opening cut into the outer wall of a room. (Fig 6) This structure with the exception of 10 mm externally ventilated air gap (total area 9,268 mm around the 285 mm flue casing at the ceiling penetration Fig 6...
  • Page 10 13 mm 40mm Air space required Air space 13 mm Air space to sides Fig 7 Minimum clearances to combustibles Fire stop (ceiling ring) must provide a minium of 9300mm of venting of enclosure ( eg 10 mm gap around the outer flue casting at ceiling penetration ) where fireplace and flue casing are fully enclosed to ceiling level.
  • Page 11 A typical flue installation Fig 8 Indoor Flue Kit - ODIDSSFLKT Contents • 4 x 203 x 900mm ( 8” ) Stainless steel flue • 1 x 203 x 150mm ( 8” ) Stainless steel flue adaptor • 4 x 279 x 900mm ( 11”) Stainless steel flue •...
  • Page 12 fireplace enclosure to provide ventilation within the enclosure ) when the fireplace is in a free standing position and the flue is exposed above the fireplace housing, is applies for both Indoor and Outdoor installations Fig 9 Fig 10 305 mm from top of fireplace for radiant models 115 mm from top of fire place opening for radiant models ( non combustibles material must separate the black face surrounds of the fireplace and any combustible mantel material ) the minimum perpendicular...
  • Page 13: Side Wall Protection

    • Side Wall Protection Adjacent combustibles side walls that are within the minimum dimensions (shown in Fig 11 of fireplace opening must be protected by a non combustible materials. • Hearth installations A hearth extension is required to protect a combustible floor in front of the fireplace .
  • Page 14 NOTE: In Australia a floor consisting of a 6 mm thick sheet of fibre cement with a thermal conductivity of 0.41 W/m degree K will be required to be extended in front of the 4000mm and 200 mm either side of the fire place opening is required.
  • Page 15: Warranty

    Raypak wood fire. This warranty must be read subject to that legislation and nothing in this warranty has the effect of excluding, restricting or modifying those rights.
  • Page 16: Warranty Conditions

    Where the wood fire is located in a position that does including: Acts of God; failure due to misuse; incorrect not comply with the Raypak wood fire installation installation; attempts to repair the wood fire other than instructions or relevant statutory requirements, causing...
  • Page 17: Additional Accessories

    Part 4: Additional Accessories ODSR36A Stainless steel twin skin extension flue kit: 1 x 279mm x 900 mm stainless steel flue DSSSEXKT Offset Flue Kit (Twin skin) DSSSOKT Offset Flue Kit (Triple skin) TSSSOKT Stainless Steel Bi Fold glass Door set 36GDKSSSR Note: The Stainless Steel Bi Fold Door accessory is to act as a weather protection device only, and must stay in the open position...
  • Page 18: Spare Parts List

    Part 5: Spare parts List Distributed by: Raypak Australia ( Division of Rheem Australia Pty Ltd ) 39 Koornang Road Scoresby Vic 3179 Ph 03 9757 3333 Fax 03 9757 3350 ABN 65078 743 414...

Table of Contents