2-1-3. AC Outlet:
Outlet sockets available:
Rear View:
2-2-1. Ventilation window:
Do not obstruct; allow at least 1 inch for air flow.
2-2-2. DC input terminals:
Connect to a battery or other voltage power source of the correct voltage.
[+] is positive; [-] is negative. Reverse polarity connection will blow the internal fuse
and may damage the inverter permanently. The input wiring should be protected by an
appropriately rated input fuse as per NEC or equivalent codes.
2-2-3. Wire to Chassis ground or to vehicle chassis using #8 AWG wire, minimum.
Warning! Operation of the inverter without a proper ground connection may result
in an electrical safety hazard.
3. Quick Hook-up and Testing:
If you would like to hook-up the power inverter and check its performance before going ahead
with your permanent installation, please follow these guidelines:
3-1.
Unpack and inspect the power inverter; check to see that the power switch is in the OFF
position.
3-2.
Connect the cables to the power input terminals on the rear panel of the power inverter.
The red terminal is positive (+) and the black terminal is negative (-). Connect the cables
into the terminals and tighten the bolts to clamp the wires securely.
3-3.
Connect the cable from the negative terminal of the inverter to the negative terminal of
the power source. Make a secure connection.
Caution! Loosely tightened connectors result in excessive drop and may cause
overheated wires and melted insulation, as well as other damage.
045670
04/11/2003 Revision -
CGL 600W INVERTER MANUAL
Page 5
Australia/New Zealand
North America/US (Standard 5-15R on all 110 -110 VAC
Models)
Europe
UK/Ireland
GFCI (US Type)
URL: www.novaelectric.com
NOVA ELECTRIC
A DIVISION OF
TECHNOLOGY DYNAMICS, INC.
100 SCHOOL STREET
BERGENFIELD, NJ 07621-2915
PHONE 201-385-0500
FAX 201-385-0702

Advertisement

loading