• If the dot clock frequency of an analog signal is 108 MHz or higher, "DOT CLOCK" and "CLOCK PHASE"
cannot be automatically corrected.
• When digital signal input, DOT CLOCK and CLOCK PHASE cannot be made.
• AUTO SETUP may not work when a cropped or dark image is input. In such case, switch to a bright image
with borders and other objects are clearly shown, and then try auto setup again.
• Depending on the signal, out of alignment may occur after AUTO SETUP. Carry out fi ne tuning for the
position/size as required.
• If AUTO SETUP cannot set properly for vertical frequency 60Hz XGA signal (1024×768@60Hz,
1280×768@60Hz, and 1366×768@60Hz), pre-selecting the individual signal in "XGA MODE" (see page
39) may results in correct AUTO SETUP.
• AUTO SETUP does not work well when a signal such as additional information is superimposed out of
valid image period or intervals between synchronizing and image signals are short, or for image signal with
tri-level synchronizing signal added.
• If AUTO SETUP cannot adjust correctly, select "NORMALIZE" once and press ACTION ( ) then adjust
POS./SIZE manually.
H-POS
Adjust the horizontal position.
H-SIZE
Adjust the horizontal size.
DOT
(During Component/PC input signal)
CLOCK
Periodic striped pattern interference (noise) may occur when a striped pattern is displayed. If this happens,
adjust so that any such noise is minimized.
CLOCK
(During Component/PC input signal)
PHASE
Eliminate the fl ickering and distortion.
CLAMP
(During Component/PC input signal)
POSITION
Adjusts the clamp position when black parts of the image have no detail due to underexposure or are tinged with green.
Optimum value for Clamp Position adjustment
When black parts have no detail due to underexposure (blackout)
→Value that causes least blackout is the optimum.
When black parts are tinged with green
→Value that cancels the greenishness without causing blackout is the optimum.
OVER
Turn image over scan ON/OFF.
SCAN
Confi gurable signals are as follows:
525i, 525p, 625i, 625p, 750/60p, 750/50p, 1125/60i, 1125/50i, 1125/24sF, 1125/25p, 1125/24p, 1125/60p,
1125/50p, 1125/30p (Component Video, RGB, DVI, HDMI)
ON
Notes:
• When "OFF" is set, "H-SIZE" and "V-SIZE" cannot be adjusted.
• When the "Display size" is set to "On" in the Options menu, this setting will be invalid. (see page 43)
Helpful Hint (
While the POS./SIZE display is active, if either the N button on the remote control is pressed at any time or the ACTION
( ) button is pressed during "NORMALIZE", then all adjustment values are returned to the factory settings.
OFF
/
Normalization)
NORMALIZE
Adjusting POS./SIZE
V-POS
Adjust the vertical position.
V-SIZE
Adjust the vertical size.