MaxPro X6-Plus User Manual

Intelligent charger/discharger

Advertisement

Quick Links

Intelligent Charger/Discharger
User's Manual
Specifications.............................................................................................2
System Features........................................................................................2
Warnings....................................................................................................2
X6-Plus charger layout...........................................................................3
General Setup & Notes..........................................................................4
B. Li-Po, Li-Ion, Li-Mn, LiFePO4 Discharge.....................................6
C. Li-Po, Li-Ion, Li-Mn Storage............................................................7
D. Li-Po, Li-Ion, Li-Mn, LiFePO4 Balance........................................8
E. Li-Po, Li-Ion, Li-Mn, LiFe Cycle.......................................................9
NiMH, NiCD, Pb CYCLE Operation & Display.................................11
Servo Test Mode Operation & Display.............................................13
POWER Mode Operation & Display..................................................14
SETUP menu Flow..................................................................................15
Error Messages........................................................................................16
X6-Plus
INDEX
1

Advertisement

Table of Contents
loading

Summary of Contents for MaxPro X6-Plus

  • Page 1: Table Of Contents

    X6-Plus User's Manual INDEX Specifications……….................…..2 System Features………………..............…2 Warnings………………................…2 X6-Plus charger layout…………….............…….3 General Setup & Notes……………….........…..……4 Li-Po, Li-Ion, Li-Mn, LiFePO4 Operation & Display….…..…..…5 A. Li-Po, Li-Ion, Li-Mn, LiFePO4 Balance Charge......5 B. Li-Po, Li-Ion, Li-Mn, LiFePO4 Discharge........6 C. Li-Po, Li-Ion, Li-Mn Storage............7 D.
  • Page 2: Specifications

    1. High power, high current, high-performance power conversion circuit. Maxpro X6-Plus uses advanced DC/DC converter technology with high output conversion efficiency 2. The X6-Plus can be used with four types of Lithium batteries (Li-Po, Li-lon, Li-FePO4, Li-Mn) and has a built-in balancer. 3. Optimized charge algorithm for NiMH/NiCd 4.
  • Page 3: X6-Plus Charger Layout

    X6-Plus charger layout Check X6-Plus charger and the standard accessories you get. The following Standard items are included in the package. Conntact your supplier if missing part or damage is found. Standard items: • Maxpro X6-Plus charger with input cables & clips •...
  • Page 4: General Setup & Notes

    1. Attach X6-Plus to an appropriate DC power supply. 2. Connect the Input Cables (Red+ & Black-) on left side of X6-Plus to the DC power supply. Then wait for the initialization to complete and the "No Battery" message to be displayed..
  • Page 5: Li-Po, Li-Ion, Li-Mn, Lifepo4 Operation & Display

    “Charging END”screen: the pack voltage, the pack temperature, the capacity charged and the time of charging. The X6-Plus will stop charging when the cells voltage reach the cut-off voltage(4.20V for Lipo & LiMn, 4.10V for LiIon, 3.60V for LiFe) or reach the capacity protection(120% of set battery capacity)
  • Page 6: Li-Po, Li-Ion, Li-Mn, Lifepo4 Discharge

    X6-Plus will set the discharging current automatically according to the battery pack's voltage & Max. discharge power LiPo e.g. 6S LiPo, the start voltage is 22.72V, X6-Plus Max. discharge power is 15W. So the Max. discharge current is 15/22.72=0.66A 3.40V/CELL 0.7A...
  • Page 7: Li-Po, Li-Ion, Li-Mn Storage

    Storage Chg LiPo 0.7A If the battery cell voltage is lover than 3.85V, X6-Plus will charge it to 3.85V. Following FLOW is the same as CHG display If the battery cell voltage is higher than 3.85V, X6-Plus will discharge it to START/ENTER 3.85V.
  • Page 8: Li-Po, Li-Ion, Li-Mn, Lifepo4 Balance

    ESC/STOP START/ENTER Press DEC & INC, Scroll through the setting of cell numbers. 22.72V GV: 16mV> X6-Plus will set the cell numbers automatically according to the Balance Type:LiPo Connector connected. START/ENTER Press DEC & INC, Scroll through the setting within...
  • Page 9: Li-Po, Li-Ion, Li-Mn, Life Cycle

    X6-Plus will set the discharging current automatically according to the LiPo 6S CYCLE battery pack's voltage & Max. discharge power. If the setting current is lower than the Max. discharging current, X6-Plus DHG<->CHG:2 1.5A will discharge the battery according to the setting current. START/ENTER DH>22.50V...
  • Page 10: Nimh, Nicd, Pb Chg Or Dhg Operation & Display

    NiMH, NiCD, Pb(Lead-Acid) CHG or DHG Operation & Display Connect the Ni** or Pb Battery Main wire Connector to X6-Plus Suggestion: Temperature sensor should be connected to X6-Plus and touched with the battery. 10.71V No Battery Type:NiMH ESC/STOP START/ENTER 10.71V...
  • Page 11: Nimh, Nicd, Pb Cycle Operation & Display

    NiMH, NiCD, Pb(Lead-Acid) CYCLE Operation & Display Connect the Ni** or Pb Battery Main wire Connector to X6-Plus Suggestion: Temperature sensor should be connected to X6-Plus and touched with the battery. No Battery 10.71V Type:NiMH ESC/STOP START/ENTER 10.71V Type:NiMH ESC/STOP...
  • Page 12: Act Mode For Nimh & Nicd Operation & Display

    ACT Mode for NiMH & NiCD Operation & Display ACT Mode can charge the NiMH or NiCD battery when the voltage can't be detected by X6-Plus, It allows the user to override the voltage sensing and force the charge cycle to run.
  • Page 13: Servo Test Mode Operation & Display

    1. Choose servo property(Analog or Digital) 2. Press "ENTER" to run the speed test program. X6-Plus will output 5V DC to turn the servo left and right automaticlly. Servo speed is displayed on the LCD (Base on 5V DC & 60° turn ) 3.
  • Page 14: Power Mode Operation & Display

    POWER Mode Operation & Display Power Mode can provide 3.0~30V adjustable DC to meet your requirement. Be sure NO equipment connect to the output socket before you choose the POWER Mode ACT SERVO POWER No Battery START/ENTER SETUP ESC/STOP ESC/STOP START/ENTER Output Set:12.8V OUT>12.80V 0.01A...
  • Page 15: Setup Menu Flow

    START/ENTER Temperature Cut-Off value range: 30~60° Temp Cut Off if any battery you are charging or discharging 50° > reaches this temperature the X6-Plus will stop the charge/discharge. ESC/STOP START/ENTER NiMH Peak NiMH Delta Peak value range: 3~20mV NiCD Peak 13mV...
  • Page 16: Error Messages

    If customer want to send the charger to MAXPRO for service, the shipping cost from customer to Maxpro is paid by the customer, and Maxpro will pay for the shipping cost for returning the repaired product to the customer.

Table of Contents