  • Page 1 Trevi Spa User Guide...
  • Page 2: Table Of Contents

    Table of contents Reminder list ....................3 Introduction ....................4 Choosing the best location for your spa ............5 During delivery ..................Installation options for your spa .............. Initial start-up procedure ................7 Winterizing procedure ..................9 Opening procedures for spas ..............12 Precautions when using your spa during winter ........13 Draining procedures ...................13...
  • Page 3: Reminder List

    Reminder list Model : Year : Height : Quantity liters : Customer number (TC) Purchase date : Important notes:...
  • Page 4: Introduction

    ▪ Pregnant women should consult their physician before using the spa. ▪ Hot water is an ideal medium for spreading infections. Do not use the spa if you have an open wound. ▪ Always be careful when entering and exiting the spa.
  • Page 5: Choosing The Best Location For Your Spa

    How will you use your spa? How you plan to use your spa will help you determine its location. For example, are you going to use it for recreational or therapeutic purposes? If your spa is mainly used for the family, please allow enough space around it for activities.
  • Page 6: Installation Options For Your Spa

    (compulsory minimum 18" clearance on each side). It is also compulsory to provide the same access if the spa is flush-mounted or embedded. If the spa is moved to access it, this will be at the customer’s cost. Make sure that all screws of the spa are accessible at all times.
  • Page 7: Initial Start-Up Procedure

    Step 1: Start-up and emptying the spa ▪ Fill the spa by inserting the hose into the skimmer, where the holes are under the cartridges, up to one inch below the neck jets (at the level of the trapezoids) or one centimeter below the lowest pad. All cushions must be outside the water.
  • Page 8 ▪ The filter cycle needs to be changed to increase the frequency and duration for a total of 8 hours of filtration daily. We recommend that you adjust the frequency rather than the duration. In this way, the spa starts up more frequently, but for less long.
  • Page 9: Winterizing Procedure

    In order to avoid unpleasant surprises, please check with your insurance company to make sure that your spa is insured. If you choose not to make optimum use of your spa and prefer closing it for the winter, we suggest that you continue to maintain it until the time of closure and have a complete test of your water done in one of our two superstores or six branches.
  • Page 10 If your system is equipped with In.Clear, refer to section Cleaning your in.clear below Step 2 : Draining the pipes You should use a Shop-Vac type vacuum with 4.5 HP blower or more to shut down your spa properly. Scenario 1: Spa with one bypass valve for each pump: ▪...
  • Page 11 Add another 1/2 cup of antifreeze into each jet. ▪ Clean your spa cover with Cover cleaner and allow to dry. Apply a coat of wax to keep leather hydrated throughout winter. Position cover on top of spa.
  • Page 12: Opening Procedures For Spas

    ▪ Make sure the spa is level. ▪ Remove wooden cover installed when winterizing. ▪ Remove cover and clean with the Cleaner for spa cover or 1 teaspoon of liquid dish soap to 9 liters of water. Rince thoroughly. ▪ Place filtering cartridges and basket in skimmer.
  • Page 13: Precautions When Using Your Spa During Winter

    ▪ If you plan on being away for an extended period of time, make sure there is someone to take care of your spa and that this person knows what to do if the spa breaks or if there is a power failure. Otherwise, shut down your spa before leaving.
  • Page 14: Winter Emergency Procedures

    Note: Be sure that hose is on a downward grade to properly drain spa. Winter emergency procedure If you need to temporarily install heaters near your spa to prevent the water from freezing in the piping and avoid damaging it, here's how: Step 1: Open the panels on the front of your spa.
  • Page 15 Step 4: Protect and insulate the spa Place a canvas of about 15' x 10' on the spa, then replace the cover. Use the center panel of your spa skirt as a wall to create a shelter with canvas.
  • Page 16 Figure 1 Note: See content of the parts at the end. Figure 1 ▪ Place the frame parts to the ground next to your spa to form a rectangle (Figure 1). Mark the center of (B) and (F) with a Courroies pencil.
  • Page 17 3/4" long self-drilling screws of the flat washer (Figure 5). ▪ Hold the frame so it is 13 cm (5") from the spa. Tighten one of the belts against the edge of the spa. Mark the spot. Fasten...
  • Page 18 5/8" bolt with hexagonal head Stabilizer Pivoting arm Installation of the hydraulic spa cover Pivoting 1 ¾" bolt Before you begin, please determine if you are making a surface or side installation. NOTE: You will find the parts drawing at the end of this document.
  • Page 19 Step 1: Attaching the removal support. Note: Place the spa cover in the closed position. Offset the back of the U-bracket for the cover border 5 cm (2") forward. Make sure the U-bracket is parallel to the spa cover. (Figure 1.1) ▪...
  • Page 20 ▪ Place the extension arms on each side of the spa and make sure that the set-back, attached, threaded cylinder is on the top. Screw the 2 pins into the end of each lower side extension arms. (Figure 4.1) Place the spa cover to the closed position and pull it forward.
  • Page 21 Rear sink clearance for 82" spa Rear sink clearance for 92" spa...
  • Page 22 They then should be rinsed thoroughly. Valves Depending on the spa, the number of valves as well as their positioning may vary. Normally, smaller valves are for air control. They allow air to be inserted into the water to make the seat jets more powerful.
  • Page 23 ▪ The cover should also be reversed on the spa twice every year for a period of 3 or 4 hours each time. Please note that it is advisable to wait approximately 20 to 30 minutes before closing the spa cover following the addition of chemicals.
  • Page 24: Trevi Spa Maintenance Products

    Trevi spa maintenance products 102234...
  • Page 25 Error codes on Spa Pack in.xm SP-HR An internal error of the in.xm equipment has been detected ▪ Restart the Spa Pack then start and stop all pumps and turbine. ▪ If the error reappears, replace the Spa Pack in.xm SP-BR The rated current of the selected entry is less than the sum of the current of all pumps ▪...
  • Page 26 SP-OT The temperature inside the spa skirt is too high The temperature inside the spa skirt is too high, causing an increase in the internal temperature of in.xm above normal limits (overheat condition). ▪ Remove the skirt of the spa and cool the system.
  • Page 27 ▪ The external ambient temperature is high enough to heat the water, even if the pumps are not operating. - Add cold water into the spa and allow the heater to cool. ▪ Reset the Spa Pack with the circuit breaker.
  • Page 28 ▪ Change the output status (on/off) of pump 1 and try all possible conditions (i.e. low, high, and stop). ▪ Reset the Spa Pack by pressing the Select button twice. ▪ If the error is not cleared, the problem is surely pump 1. It must be replaced.
  • Page 29 ▪ Make sure that the fan is connected correctly. ▪ Change the output status (on/off) of the fan. ▪ Reset the Spa Pack . ▪ If the error is not cleared, the problem is surely the fan. It must be replaced.
  • Page 30: Spa Pack Error Codes

    Spa Pack in.xe error codes An internal in.xe equipment error was detected. ▪ Restart the Spa Pack ; then start and stop all pumps and turbine. ▪ If the error reappears, replace the Spa Pack in.xe . The system has detected a problem in the control probe. The system constantly checks if the control probe readings are within normal limits.
  • Page 31: Compulsory And Optional Training

    ▪ Check that the spa has enough water to work properly (a minimum of 18 gpm must circulate in the water heater). ▪ Remove the spa skirt and let the system cool down until the error disappears.
  • Page 32: Customer Access

    Your contacts Thank you for placing your trust in Trevi You can, at any time, view and retrieve online guarantees, construction specifications, installation guides, procedures for opening and closing, maintenance guides and a host of important documents for the proper operation of your new purchase at TREvI.CA - Customer Access...