Download Print this page

Dimplex FX 20 IPX4 Installation And Operating Instructions page 3

Downflow fan heater

Advertisement

Installation Procedure
It is essential to observe minimum wall mounting clearances - see Fig. 1.
The appliance should be fitted horizontally, with the cable entry at the top
and grille at the bottom. It must be mounted not less than 1800mm above
the floor with a clearance of at least 600mm to any shelf or projecting
surface below the heater and not less than 300mm below the ceiling or
other projecting surface. It must also be not less than 250mm from an
adjacent projecting surface. For most effective heating performance, the
heater should be mounted at the minimum height : i.e. 1800mm above
the floor.
Care must be taken to ensure that when in use, the air stream is not
obstructed by a high shelf or cabinet.
The appliance is secured to the wall with three screws, two through
keyhole slots '1' and '3' and one through a hole '2' to hold the appliance
firmly in position (see Fig. 2).
1.
Remove the top cover from the appliance by removing the two
screws securing the top cover and hinging it back.
2.
Mark the position of the two keyhole slots '1' and '3' (see Fig. 2 for
dimensions) on the wall and drill and plug for the two suitable
screws.
3.
Partially insert the two screws, then hang the appliance on these
screws. Mark the position of the third hole. this is used to secure the
product.
4.
Remove the appliance and drill and plug for the third screw.
5.
Remount the appliance on the wall using the two keyhole slots.
6.
Feed the supply cord or wires through the inlet at the top rear of the
appliance leaving sufficient free length to connect to the terminal
block.
7.
Make electrical connections to the terminal block ensuring that the
live connection is made to the terminal marked 'L' and the neutral
connection to the terminal marked 'N' (see Fig. 2 exploded view).
8.
Fix the product inplace by inserting and tightening the third screw.
Fix mains cable securly using the products cable clamp
9.
Set the selector switch to provide either 1kW or 2kW output.
10. Replace the top cover and screws.
The appliance is now ready for use and the electricity supply can be
reinstated.
M
The product complies with the European Safety Standards EN60335-2-30 and the European Standard Electromagnetic Compatibility (EMC) EN55014,
EN60555-2 and EN60555-3. These cover the essential requirements of EEC Directives 2006/95/EC and 2004/108/EC
Dimplex UK Ltd.
Millbrook House
Grange Drive
Hedge End
Southampton
Hampshire. SO30 2DF
[c] Dimplex UK Limited
All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Dimplex UK Limited.
Fig. 2
Fig. 3 - FX20IPX4 Wiring Diagram
FX20IPX4 Controls
The heater is fitted with a pull cord
operated ON/OFF switch, a thermostat, a
cut-out, and a thermal fuse link.The
heater has an internal adjustable
thermostat which can be adjusted by
installer (i.e. the top cover has to be
removed), see Fig. 4 for controls details
with cover removed. Temp. range 18°C -
32°C.
Cleaning and User Maintenance
WARNING: BEFORE UNDERTAKING CLEANING OR MAINTENANCE WORK
ON THE APPLIANCE DISCONNECT THE ELECTRICITY SUPPLY BY
SWITCHING OFF AT THE ADJACENT DOUBLE POLE SWITCH.
The outside can be cleaned by wiping it over with a soft damp cloth and
then dried. Do not use abrasive cleaning powders or furniture polish as this
can damage the surface finish.
Ensure that dust or fluff does not accumulate inside the heater as this could
lead to overheating of the element. Use a vacuum cleaner to remove any
fluff which does accumulate.
Recycling
For electrical products sold within the European Community.
At the end of the electrical products useful life it should not
be disposed of with household waste. Please recycle where
facilities exist. Check with your Local Authority or retailer for
recycling advice in your country.
After Sales Service
If this product appears damaged when first received or does not
function correctly contact us by e-mail aftersales@dimplex.co.uk or
ring 0844 879 35 88 and we will be able to help. For ROI please phone
018424833.
Do Not Return the product in the first instance as this may delay us
providing you with a satisfactory service.
ACCIDENTAL DAMAGE IS NOT COVERED UNDER THE WARRANTY.
Your product is guaranteed for two years from the date of purchase.
Within this period, we undertake to repair this product free of charge
provided it has been installed and operated in accordance with these
instructions.
Should you require assistance with this product please go to
www.dimplex.co.uk and click on "Customer Support" or e-mail us at
aftersales@dimplex.co.uk
Alternatively ring our contact centre on 0844 879 35 88 (UK only). This
is a Lo-call no. from a BT landline - other providers including mobile
phones may charge you more. For ROI please phone 01 842 4833.
To assist you, we will need the following information: model number and
serial no (these can be found on the product), nature of the fault and date
of purchase. Please retain your receipt as proof of purchase. Your
rights under this guarantee are additional to your statutory rights, which
in turn are not affected by this guarantee.
Spares can be purchased on line, go to
selector
switch
internal adjustable
thermostat knob
Fig. 4
www.dimplex.co.uk/outlet_store

Advertisement

loading