Schoeps VSR 5 U Operating Manual page 8

Table of Contents

Advertisement

Here the 80-Hz low-cut filter has been acti-
vated.
button a second time. The filter selection is
stored when the preamplifier is turned off,
and is set automatically the next time the unit
is turned on.
Level Indicator
The signal level indicator of the VSR 5 con-
sists of 21 LEDs including a "Clip" LED.
The level is indicated in steps of 3 dB. The
range from -48 to -15 dB is shown in green,
the range from -12 to -3 dB in yellow, and
the LEDs for 0 to +9 dB are red, as is the
"Clip" LED.
A full-wave DIN PPM peak detector drives
the display with an attack time of <10 ms
and a decay time of 0.5 seconds per 20 dB.
VSR 5 output socket
2
1
3
X
VSR 5 output socket
2
1
3
X
Connecting the inputs and outputs of the VSR 5
8
SCHOEPS GmbH · Spitalstr. 20 · D-76227 Karlsruhe (Durlach) · Tel: +49 (0)721 943 20-0 · Fax: +49 (0)721 495 750
Note:
During production, the reference level of the
0 dB LED is set to +6 dBu.
"Clip" Indicator
The red "Clip" LED has a fixed reference
voltage. It begins to blink at levels above ca.
+20 dBu, thus giving a warning before there
is any possible overload.
Outputs
The SCHOEPS VSR 5 is equipped with two
separate electronically balanced XLR outputs
per channel.
The gold-plated XLR output sockets are on
the rear panel of the unit. In accordance
with international standards, the layout is:
Pin 1 = Ground
Pin 2 = (+) Phase
Pin 3 = (–) Phase
Note: The VSR 5 has floating, servo-balanced
outputs. Thus if either pin 2 or 3 is grounded,
the output levels will remain the same as in
balanced operation.
Do not connect the plug connector's
housing to pin 1.
balanced
input
Do not connect the plug connector's
housing to pin 1.
unbalanced
In this case pin 3 must be connected
input
to pin 1 (ground), since pins 2 and 3 of
the output from the VSR 5 are floating.
Operating Controls
www.schoeps.de · mailbox@schoeps.de

Advertisement

Table of Contents
loading

Related Products for Schoeps VSR 5 U

Table of Contents