DIS CCS 7800 User Manual

Cp 7851 camera control package
Table of Contents

Advertisement

Quick Links

CCS 7800
User Manual
Camera Control System
CP 7851 Camera Control Package
Version 2.0
Danish Interpretation Systems
DIS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CCS 7800 and is the answer not in the manual?

Questions and answers

Summary of Contents for DIS CCS 7800

  • Page 1 CCS 7800 User Manual Camera Control System CP 7851 Camera Control Package Version 2.0 Danish Interpretation Systems...
  • Page 2 Danish Interpretation Systems User Manual Copyright © 2012 DIS CP 7851 USER MANUAL - REV E.DOC 29-10-2012 No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the...
  • Page 3: Table Of Contents

    Trouble shooting ........... 42 Add a new microphone unit ......21 microphone unit in Direct CU Mode ... 21 Copyright © 2012 DIS CP 7851 USER MANUAL - REV E.DOC 29-10-2012 No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the...
  • Page 4: Introduction

    SW 7810 Microphone and Camera Control Software • Camera System Control Unit with preloaded SW 7820 Camera Control Software The CP 7851 Camera Control Package is part of the CCS 7800 Camera Control System. Further products • Wireless Router...
  • Page 5: Part List

    Important It is important, that the settings in the iPad (IPC): ‘Settings/iRidium’ is not changed. If changed the ‘DIS Camera Control’ software might be deleted in the iPad and the iPad has to be send to factory for upload of new software.
  • Page 6: Use With Sw 6000, Eca Application

    Danish Interpretation Systems CP 7851 User Manual Use with SW 6000, ECA application Schematic Single Camera, ECA Connection Single Camera, ECA Connection Manual 02 19 78510...
  • Page 7: Setting Up The System For Eca Mode

    Danish Interpretation Systems CP 7851 User Manual Setting up the system for ECA Mode 1. Connect the system as shown in above # Description Comment or picture schematic ‘Single Camera, ECA connection’, using the RS 232 cables supplied. IMPORTANT: The RS 232 connector on the PC running the ECA shall be connected to PORT 1 on the SCU using the supplied RS 232 cable plus the RS232 adapter.
  • Page 8: Using The Ipad Control In Eca Mode

    Camera Control Unit with LAN cable Network. The ‘xxx’ is the system serial no. DIS CP 7851-xxxA Password for the network: DO NOT select the DIS CP 7851-xxxB 123456789 network. Start “iRidium HD” on the iPad. Touch the screen to Start.
  • Page 9: Main Menu In Eca Mode

    Danish Interpretation Systems CP 7851 User Manual The Main Menu window will be shown on Main Menu in ECA Mode right and consist of the following menus: Camera Operation Camera Presets Setup System The “Camera Operation” is used for Camera Operation operating the cameras manual if desired.
  • Page 10: Camera Presets

    Danish Interpretation Systems CP 7851 User Manual The screen is used to save the preset for Camera Presets each microphone. How to save presets: 1. Turn on one microphone (the seat number will be shown in the “Seat Number” field for that microphone). 2.
  • Page 11: Setup System

    Danish Interpretation Systems CP 7851 User Manual No. of Cameras Setup System Select the number of cameras connected (1 to 4) Max. NOM to Overview Select the Number Of Microphones (1 to 8) which can be opened before the system switches to the overview picture Overview delay (sec) Adjusting the delay before switching to the overview picture (1-10 sec).
  • Page 12: After The System Is Setup

    Danish Interpretation Systems CP 7851 User Manual After the system is setup After having set up all camera presets and saved the Layout (s) the system is ready to use. The iPad (IPC) and the Wireless Router (WR) can be switched Off as they are only needed for setting up the system.
  • Page 13: Use With Cu 60Xx, Direct Cu Connection

    Danish Interpretation Systems CP 7851 User Manual Use with CU 60xx, direct CU connection Schematic Single Camera, CU 6005/11 Connection Single Camera, CU 6005/11 Connection Manual 02 19 78510...
  • Page 14: Setting Up The System For Direct Cu Mode

    Danish Interpretation Systems CP 7851 User Manual Setting up the system for Direct CU Mode 14 Connect the system as shown in above # Description Comment or picture schematic ‘Single Camera, CU 6005/11 connection’, using the cables supplied. IMPORTANT: The RS 232 connector on the CU 6005/11 shall be connected to PORT1 on the SCU using the supplied RS 232 cable.
  • Page 15: Using The Ipad Control In Direct Cu Mode

    Camera Control Unit with LAN cable Network. The ‘xxx’ is the system serial no. DIS CP 7851-xxxA Password for the network: DO NOT select the DIS CP 7851-xxxB 123456789 network. Start “iRidium HD” on the iPad. Touch the screen to Start.
  • Page 16: Microphones

    Danish Interpretation Systems CP 7851 User Manual The “Microphones” is used for operating Microphones and see the microphones status. Select which microphones to operate using the menu buttons in the bottom. The microphones can now be operated using the menus. Microphones can be switched on, all delegates can be switched off, next requested delegate can be switched on and all request(s) can be...
  • Page 17: Camera Operation

    Danish Interpretation Systems CP 7851 User Manual The “Camera Operation” is used for Camera Operation operating the cameras manual if desired. Select which camera to operate using the camera buttons in lower left corner (up to four cameras). The camera can now be operated using the arrow buttons for UP/Down and Left/Right movement.
  • Page 18: Camera Presets

    Danish Interpretation Systems CP 7851 User Manual The screen is used to save the preset for Camera Presets each microphone. How to save presets: 1. Turn on one microphone (the seat number will be shown in the “Seat Number” field for that microphone). 2.
  • Page 19: Setup System

    Danish Interpretation Systems CP 7851 User Manual No. of Cameras Setup System Select the number of cameras connected (1 to 4) Max. NOM to Overview Select the Number Of Microphones (1 to 8) which can be opened before the system switches to the overview picture Overview delay (sec) Adjusting the delay before switching to the overview picture (1-10 sec).
  • Page 20: Seat Setup

    Danish Interpretation Systems CP 7851 User Manual This page is used to assign a seat number Seat Setup to each microphone unit. Be sure that either Automatic or FIFO has been selected as Operation Mode in the Conference menu before seat setup is started.
  • Page 21: Add Or Exchange Microphone Unit, Direct Cu Connection

    Danish Interpretation Systems CP 7851 User Manual Add or exchange microphone unit, direct CU connection Procedure for adding or exchanging a microphone unit in Direct CU Mode The camera control system work by seat numbers and therefore it is important that the seat number list is maintained and correct, also if a conference unit is added to the installation or if a broken unit is exchanged.
  • Page 22: Exchange A Conference Unit

    Danish Interpretation Systems CP 7851 User Manual Be sure that either Automatic or FIFO has Exchange a conference unit been selected as Operation Mode in the Conference menu before Seat Setup is selected. How to exchange a microphone unit: 1. Select Seat Setup in the System Setup menu.
  • Page 23: Use With Dds 5900, Tcp/Ip Mode

    Danish Interpretation Systems CP 7851 User Manual Use with DDS 5900, TCP/IP mode Schematic Single Camera, TCP/IP connection Single Camera, TCP/IP Connection Manual 02 19 78510...
  • Page 24: Setting Up The System For Tcp/Ip Mode

    Danish Interpretation Systems CP 7851 User Manual Setting up the system for TCP/IP mode 30 Connect the system as shown in above # Description Comment or picture schematic ‘Single Camera, TCP/IP connection’. The Visca cable from the Camera shall be connected to PORT 2 on the SCU.
  • Page 25: Using The Ipad Control In Tcp/Ip Mode

    Camera Control Unit and CU 5905 with LAN cables connected Network. The ‘xxx’ is the system serial no. DIS CP 7851-xxxA Password for the network: DO NOT select the DIS CP 7851-xxxB 123456789 network. Start “iRidium HD” on the iPad. Touch the screen to Start.
  • Page 26: Main Menu In Tcp/Ip Mode

    Danish Interpretation Systems CP 7851 User Manual The Main Menu window will be shown on Main Menu in TCP/IP Mode right and consist of the following menus: Camera Operation Camera Presets Setup System The “Camera Operation” is used for Camera Operation operating the cameras manual if desired.
  • Page 27: Camera Presets

    Danish Interpretation Systems CP 7851 User Manual The screen is used to save the preset for Camera Presets each microphone. How to save presets: 9. Turn on one microphone (the seat number will be shown in the “Seat Number” field for that microphone). 10.
  • Page 28: Setup System

    Danish Interpretation Systems CP 7851 User Manual No. of Cameras Setup System Select the number of cameras connected (1 to 4) Max. NOM to Overview Select the Number Of Microphones (1 to 8) which can be opened before the system switches to the overview picture Overview delay (sec) Adjusting the delay before switching to the overview picture (1-10 sec).
  • Page 29: After The System Is Setup

    Danish Interpretation Systems CP 7851 User Manual After the system is setup After having set up all camera presets and saved the Layout (s) the system is ready to use. The iPad (IPC) and the Wireless Router (WR) can be switched Off as they are only needed for setting up the system.
  • Page 30: Multiple Cameras, Simple Switcher, Cu 6005/11 Connection

    Danish Interpretation Systems CP 7851 User Manual Multiple Cameras, Simple Switcher, CU 6005/11 Connection Manual 02 19 78510...
  • Page 31: Multiple Cameras, Simple Switcher, Eca Connection

    Danish Interpretation Systems CP 7851 User Manual Multiple Cameras, Simple Switcher, ECA Connection Manual 02 19 78510...
  • Page 32: Multiple Cameras, Simple Switcher, Cu 5905 Connection

    Danish Interpretation Systems CP 7851 User Manual Multiple Cameras, Simple Switcher, CU 5905 Connection Manual 02 19 78510...
  • Page 33: Extron Iss 506 Seamless Switcher

    Danish Interpretation Systems CP 7851 User Manual Extron ISS 506 Seamless Switcher This switcher is connected using LAN connection. The cameras will be controlled/switched by commands send from Camera System Controller via LAN connection. The Switcher has to be set to use IP address: 192.168.10.111 Multiple Cameras, Seamless Switcher, CU 6005/11 Connection Manual 02 19 78510...
  • Page 34: Multiple Cameras, Seamless Switcher, Eca Connection

    Danish Interpretation Systems CP 7851 User Manual Multiple Cameras, Seamless Switcher, ECA Connection Manual 02 19 78510...
  • Page 35: Multiple Cameras, Seamless Switcher, Cu 5905 Connection

    Danish Interpretation Systems CP 7851 User Manual Multiple Cameras, Seamless Switcher, CU 5905 Connection Manual 02 19 78510...
  • Page 36: Multiple Cameras, Seamless Switcher, Video Encoder, Cu 6005/11 Connection

    Danish Interpretation Systems CP 7851 User Manual Multiple Cameras, Seamless Switcher, Video Encoder, CU 6005/11 Connection Manual 02 19 78510...
  • Page 37: Multiple Cameras, Seamless Switcher, Video Encoder, Cu 5905 Connection

    Danish Interpretation Systems CP 7851 User Manual Multiple Cameras, Seamless Switcher, Video Encoder, CU 5905 Connection Manual 02 19 78510...
  • Page 38: Axis M7001 Video Encoder

    Danish Interpretation Systems CP 7851 User Manual The AXIS M7001 Video Encoder is recommend to be used together with CP 7851 Camera Control Package AXIS M7001 Video Encoder but is not part of the system. The AXIS M7001 Video Encoder will stream the video from either a single camera, from the Extron MSW Mini Switcher or Extron ISS 506 Seamless Switcher to the network and also to the iPad camera control software.
  • Page 39 Danish Interpretation Systems CP 7851 User Manual In the Basic Setup under Setup select TCP/IP. Under IPv4 select “Use the following IP Address” and then type in: IP address: Subnet mask: • 192.168.10.91 Default router: 192.168.10.1 • 255.255.255.0 • Press save and ok twice. Wait approx. 30 sec and then the IP Address has been changed on the AXIS M7001 and it is ready to be used with camera system.
  • Page 40: Changing Of Wireless Router Channel

    Danish Interpretation Systems CP 7851 User Manual Changing of Wireless Router Channel 42. Connect a PC to the Wireless Description Comment or picture Router using one of the four LAN ports and turn on power to the Linksys. Can also be connected via the wireless connection by a PC or the iPad.
  • Page 41 Danish Interpretation Systems CP 7851 User Manual Below is VISCA cables configuration for both RS-422 and RS-232 for Sony cameras. Manual 02 19 78510...
  • Page 42: Trouble Shooting

    1. Change the ‘Wireless Channel’ on the the connection is un-stable router. Please refer to the section ‘Change Wireless Channel of Wireless Router’ 2. Check that the wireless connection ‘DIS CP 7851-xxxA’ is used. Do NOT connect to ‘DIS CP7851-xxxB’ Manual 02 19 78510...
  • Page 43 Danish Interpretation Systems CP 7851 User Manual No camera movement when pressing the ‘Speak’ 1. Check, that the system in not in ‘Seat Setup’ button the microphone mode (for connection mode: Direct CU or TCP/IP Mode) in the ‘Assign Seat’ menu 2.

Table of Contents