Industrial Precision Instruments IPI-BI16 User Manual

Thermal imager

Advertisement

Quick Links

IPI-BI16 Thermal Imager
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for Industrial Precision Instruments IPI-BI16

  • Page 1 IPI-BI16 Thermal Imager User Manual...
  • Page 2: Table Of Contents

    Chapter 8 Battery status ........................22 Chapter 9 Trouble Shooting ......................23 Chapter 10 IPI-BI16 Standard Packing List ..................24 This manual must not, in whole or part, be copied, photocopied, reproduced, translated or transmitted to any electronic medium or...
  • Page 3: Chapter 1 Introduction

    User Manual Chapter 1 Introduction IPI-BI16 is of ultra-compact, lightweight & unparalleled design, low power dissipation, more reliable functionality and robust performance. IPI-BI16 can penetrate through haze, smoke, rain, snow and total darkness to track and aim target which is difficult to be observed by human eyes in both day and night, and all weather condition.
  • Page 4 IPI-BI16 Thermal Imager User Manual Features: High resolution uncooled FPA technology Binocular viewer display. Able to freeze and save the picture of infrared image. Able to record the video of infrared image. The saved infrared picture and video can be played on the thermal imager.
  • Page 5: Chapter 2 Precautions

    Do not direct the IPI-BI16 Thermal Imager at high temperature target when power-on the IPI-BI16 Thermal Imager. When the IPI-BI16 Thermal Imager is not in use or is to be transported, ensure that the battery is taken out and the unit is stored in the protective carry case.
  • Page 6: Chapter 3 Maintenance

    IPI-BI16 Thermal Imager User Manual Chapter 3 Maintenance To ensure that the IPI-BI16 Thermal Imager is kept in a good working condition and remains fully functional operation, the following guidelines should be respected at all times: All User Manuals and leaflets should be read thoroughly before proceeding with operation of the equipment, please contact us if there is any unclear.
  • Page 7: Chapter 4 Technical Specification

    IPI-BI16 Thermal Imager User Manual Chapter 4 Technical Specification Detector Detector material: Uncooled FPA microbolometer Spectral Range: 1 4µm ~ Pixels: 384x288 Pitch: 25µmx25µm Imaging Performance Lens: 61mm/F0.8 motorized lens FOV: 9.06° ×6.8° Focus: 61mm Detector MRTD: 0.24mrad ~ ∞...
  • Page 8 IPI-BI16 Thermal Imager User Manual Power dissipation : < 5 W@25° C Battery Operating Time: 2 hr@25° C > Environmental Parameters Operating Temperature: -40° C + 60℃ (without battery) ~ Sine wave 5Hz 2 00Hz 5 Hz accelerated speed: 1.5g ~...
  • Page 9: Chapter 5 Buttons And Interface Of Imager

    IPI-BI16 Thermal Imager User Manual Chapter 5 Buttons and interface of imager IPI-BI16 Thermal Imager figure: Lens Buttons Battery Case Belt USB\Video\RS232 Port Ocular Power Port Ocular The buttons on the IPI-BI16 Thermal Imager:...
  • Page 10 IPI-BI16 Thermal Imager User Manual Button instruction: Button Function Description Power Switch on/off the camera Press this button to select the menu items and enter the Menu extending function menu Parameter adjusting button + (Increase) Increase Extra menu items enter button + (Increase)
  • Page 11 IPI-BI16 Thermal Imager User Manual Two Ports on the IPI-BI16 Thermal Imager: IPI-BI16 can be handheld and mounted on the tripod, and the bottom screw hole is used for mounting.
  • Page 12: Chapter 6 Quick Start Guide

    Chapter 6 Quick start guide 6.1. Preparation The operator could hand hold the IPI-BI16 Thermal Imager, or fix it on the tripod. According to the thermal imager interface definition, connect the enclosed video/USB cable, power cable and 12V power adapter to the display equipment and AC power shown as below picture.
  • Page 13: Quick Start Guide

    IPI-BI16 Thermal Imager User Manual If there is no power supply, the Thermal Imager can also be powered by the enclosed 7.2V/2AH Li-ion battery. Counterclockwise wring out the battery case cover and insert the battery with the pole against the reed. Please ensure good contact of the battery electrode and the reed inside the battery case.
  • Page 14 IPI-BI16 Thermal Imager User Manual After start-up, the thermal imager will automatically conduct the non-uniformity calibration. If non-uniformity still exists in image long after power-on test, perform non-uniformity calibration manually. Two calibration ways: Calibration with shutter: press calibration button to conduct the calibration on the target with the built-in shutter.
  • Page 15 IPI-BI16 Thermal Imager User Manual Power-off: When operation completed, firstly put back the lens cover, then press and hold the power button till the shut-down progress bar on the screen reach its right end. After that, remove the cables from the sight by holding the lock pin on the cable and pulling it out.
  • Page 16: Chapter 7 System Operation

    IPI-BI16 Thermal Imager User Manual Chapter 7 System operation 7.1. Power Instructions icon When the thermal imager works with the external power supply, a plug mark will present on the top- right corner of the screen as the below image shown.
  • Page 17: Help Menu

    IPI-BI16 Thermal Imager User Manual 7.2. Help Menu After start-up, press the menu button, and the menu bar will be presented on the screen as the below image shown. The button instruction will be displayed to state the buttons function on the screen, and user can operate as the button instruction. Select option Help to view how to operate the camera.
  • Page 18: Electronic Zoom

    IPI-BI16 Thermal Imager User Manual In semi-auto mode, user can adjust B value to get expected image brightness, camera will calculate the offset value automatically. User can adjust C value to manually adjust gain value. 7.3.3. Electronic Zoom The thermal imager can also conduct electronic zoom function. After selecting the electronic zoom menu Z, press the +...
  • Page 19: Whot & Bhot

    User Manual 7.3.4. wHOT & bHOT IPI-BI16 uses different gray level to indicate different temperature. Under wHOT mode, brighter part represents higher temperature. While under bHOT mode, brighter part represents lower temperature. Select menu wHOT item, press + or - buttons to switch between 2 polarity modes.
  • Page 20: Freeze And Save The Infrared Image

    IPI-BI16 Thermal Imager User Manual 7.4. Freeze and save the infrared image 7.4.1. Key function Description To freeze the infrared image. To save the frozen infrared image. After image freezing, press button - to start record infrared video. During infrared video recording,...
  • Page 21: Save And Exit

    IPI-BI16 Thermal Imager User Manual User can operate the system based on button instruction displayed. 7.4.3. Save and Exit When the image is frozen, press + button to save the picture in the internal SD card. Press button M to exit to real time infrared image.
  • Page 22: Infrared Video Record

    IPI-BI16 Thermal Imager User Manual 7.5. Infrared video record After freezing the image, press button - to start recording infrared video. Video will be saved to SD card automatically while it’s being recorded. In the recording process, it will display the current recording time and remaining time on the top left corner.
  • Page 23: Parameter Setting

    IPI-BI16 Thermal Imager User Manual 3. Exit Press M to exit video recording, return to real time infrared image status. Recorded video will be automatically saved to SD card. 7.6. Parameter Setting 7.6.1. Button instructions Button Descriptions Select menu Enter into submenu or adjust parameters of highlighted option and...
  • Page 24: Auto Mode Setting

    IPI-BI16 Thermal Imager User Manual It is suggested turn option NOTE on, and control the camera by following the instructions ExpertMenu is for factory debugging, and not open for users. 7.6.2. Auto mode setting Select option Auto, and press button + or - to shift between auto mode and semiauto mode.
  • Page 25: Cursor Display And Movement

    IPI-BI16 Thermal Imager User Manual 7.6.3. Cursor display and movement 0 no cursor display 1~3, three different cursor can be selected X, Y, select the option and adjust +and-to move the cursor. 7.6.4. Note setting Select option NOTE, and press button +and-to adjust on and off this function. It is suggested to turn this function on so to control the camera with instruction of each operation.
  • Page 26: Thermal Image And Video Review

    IPI-BI16 Thermal Imager User Manual Select option No and confirm will cancel the operation; select Yes and confirm to format the SD card. Dialog box will display as below. Press button M to confirm the format. 7.6.6. Factory setting Selection option FactorySetting, and press button + and-to perform this setting.
  • Page 27 IPI-BI16 Thermal Imager User Manual The saved infrared pictures will be displayed as above picture shown (Maximum 6 pictures can be displayed on the screen).The picture file name will be displayed on the right of the screen, and the button function instruction will be displayed at the bottom of the screen.
  • Page 28 IPI-BI16 Thermal Imager User Manual Four kinds of operation can be done on the saved image 1. press button + and - to select among the saved images 2. press button R to adjust the opened image 3. press button C to delete the image User can make selection according to the indication in the bottom of dialog box.
  • Page 29: Thermal Video Review

    IPI-BI16 Thermal Imager User Manual User can make selection according to the indication in the bottom of dialog box. Select option No and confirm will cancel the operation; select Yes and confirm to delete the open image; select all and confirm to bring out dialog box as below.
  • Page 30 IPI-BI16 Thermal Imager User Manual The saved infrared videos will be displayed as above picture shown (Maximum 6 thumbnails can be displayed on the screen).The video file name will be displayed on the right of the screen, and the button function instruction will be displayed at the bottom of the screen.
  • Page 31 IPI-BI16 Thermal Imager User Manual User can make operation according to the indication in the bottom of dialog box. Press button + and – to play forward or backward. Press button R to stop the play. Press button M to stop/resume the play. Press button M to exit play and back to the video view interface.
  • Page 32: Transmit The Picture And Video From The Thermal Imager To Pc

    IPI-BI16 Thermal Imager User Manual Select No and confirm to cancel the operation; select Yes and confirm to delete all the videos. 7.7.3.4. Exit Videoview Press button M to exit Videoview interface. 7.8 Transmit the picture and video from the thermal imager to PC The method of transmitting the picture and video from the thermal imager to PC is the same as the digital camera picture transmitting.
  • Page 33: Chapter 8 Battery Status

    IPI-BI16 Thermal Imager User Manual Chapter 8 Battery status The IPI-BI16 runs for over 2 hours by using one 7.2V/2AH rechargeable Li-ion battery in normal environment. Battery charging Method: 1. Aim the Li-ion battery electrode to the charger’s electrode, and insert the battery into the charger.
  • Page 34: Chapter 9 Trouble Shooting

    IPI-BI16 Thermal Imager User Manual Chapter 9 Trouble Shooting If the IPI-BI16 malfunctions please check the items listed below first, if the problem is not listed please contact us as soon as possible. Trouble Reason/Measure ·No battery or lack of power; remove battery and install a...
  • Page 35: Chapter 10 Ipi-Bi16 Standard Packing List

    IPI-BI16 Thermal Imager User Manual Chapter 10 IPI-BI16 Standard Packing List Name IPI-BI16Thermal imager Video/USB cable/RS 232 RS232 communication cable Power cable 7.2V/2AH rechargeable Li-ion battery AC adapter I NPUT:110-240VAC 1.0A 50/60Hz ( OUTPUT:12VDC 4.0A MAX. ) Battery recharging case...