ECM SERIES ELECTRIC FURNACE
• Never tamper with the unit or its controls. User MUST contact
a specialized contractor when a failure occurs. DO NOT
ATTEMPT to repair.
• When using a humidifier make sure not to damage the heating
element bank.
• We recommend that your unit be inspected by a specialized
technician once a year.
• Poor maintenance of air filters OR an unbalanced static
pressure may result in a performance decrease.
• Always use genuine parts for maintenance or service call.
The use of unbranded parts will void the warranty.
• The use of this unit without an air distribution duct will void
the warranty.
• It is strictly forbidden to use jumpers to simulate heat demand.
• Risk of electrical shock. Disconnect power before installation,
servicing, maintenance or field wiring. Replace all panels
before operating. Failure to do so can result in electrical
shock causing severe injuries or death.
• When performing installation, servicing or cleaning the unit,
it is recommended to wear safety glasses and gloves.
• To assure a proper performance of your furnace, we recommend
that you use high quality name brand thermostats.
• When applicable local regulation comprises more restrictive
installation and/or certification requirements, the aforementioned
requirements prevail on those of this document and the
installer agrees to conform to these at his own expenses.
• For your safety, do not store or use gasoline or other flammable
liquids and vapors in the vicinity of this unit or any other
appliance.
• These instructions are intended to be use by qualified personnel
who have been trained in installing this type of furnace.
Installation of this furnace by an unqualified person may
lead to equipment damage and/or hazardous condition
which may lead to bodily harm.
• Never burn garbage or paper in the heating system and never leave rags or paper around the unit.
• Return air grilles and warm air registers must not be obstructed.
IMPORTANT: All local and national code requirements governing the electrical installation heating equipment, wiring and flue connections
must be followed. Some of the codes that may be applicable are:
ANSI/NFPA 70 NATIONAL ELECTRICAL CODE
CSA C22.1 CANADIAN ELECTRICAL CODE
Only the latest issues of the above codes should be used, and are available from either:
The National Fire Protection Agency
Batterymarch Park
Quincy, MA 02269
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
MISSISSAUGA, ONTARIO L5T 1H9
WARNING
!
• This furnace is not watertight and is not designed for outdoor
installation. This furnace shall be installed in such a manner
as to protect its electrical components from water. Outdoor
installation leads to a hazardous electrical condition and to
premature furnace failure, thus voiding the warranty.
• Do not block the combustion air openings in the furnace.
Any blockage will result in improper overheat situation and
may result in a fire hazard and/or cause bodily harm.
• The unit must have an uninterrupted or unbroken electrical
ground to minimize personal injury if an electrical fault
should occur. When performing electrical connection, the
ground conductor must be firmly attached to the ground lug
in the furnace.
• Do not use this furnace as a construction heater. Use of this
furnace as a construction heater exposes the furnace to
abnormal conditions, contaminated combustion air and the
lack of air filters. Failure to follow this warning can lead to
premature furnace failure and/or vent failure which could
result in a fire hazard and/or bodily harm.
• The owner and/or the user is responsible of the following:
Always maintain the immediate surrounding of the furnace
free from combustible and highly flammables materials.The
furnace ambient air should not have an excessive dust
concentration and humidity. Never operate this central heating
appliance without an air filter.
• Before performing any service functions, unless operations
specifically require the power to be on, make sure all utilities
are turned "OFF" upstream of the appliance. Failure to comply
with this warning will cause a fire hazard and/or bodily
harm.
• All questions regarding the operation, maintenance or warranty
of this unit should be addressed to the company where this
product has been sold from.
CAUTION
or
CUSTOMER SERVICE TEL.: 1-888-882-7626
The Canadian Standards Association
178 Rexdale Blvd.
Rexdale, Ontario M9W 1R3
TEL.: 905-670-2500
FAX: 905-795-8311
30042458A

Advertisement

Table of Contents
loading

Summary of Contents for Broan ECM SERIES

  • Page 1 MISSISSAUGA, ONTARIO L5T 1H9 TEL.: 905-670-2500 FAX: 905-795-8311 CUSTOMER SERVICE TEL.: 1-888-882-7626 ECM SERIES ELECTRIC FURNACE WARNING • Never tamper with the unit or its controls. User MUST contact • This furnace is not watertight and is not designed for outdoor a specialized contractor when a failure occurs.
  • Page 2: General Requirements And Specifications

    INSTALLATION AND OPERATING INSTRUCTIONS This furnace has been designed and manufactured to give the The safe and dependable operation of the furnace depends upon most reliable performance possible. Each unit has been given a proper installation and compliance with all national and local running inspection before shipment to assure that every component codes and standards.
  • Page 3: Operating Options

    GENERAL REQUIREMENTS AND SPECIFICATIONS (CONT’D) 240 VOLTS – SINGLE PHASE TEMP. RISE @ 0.20 in. W.C. MODEL NO. kW BTUH AMPS INCL. MOTOR HP BLOWER °C °F *SPEED 21ECM10 34120 MEDIUM 21ECM15 51180 MEDIUM 10” x 8” 21ECM18 61420 MEDIUM (254 mm x 203 mm) 21ECM20 68240...
  • Page 4: Installation Notes

    E. Read the current draw on the meter and reset the anticipator to match the meter reading. FOR USE IN MOBILE HOMES ECM Series furnaces models 21ECM10, 21ECM15, 21ECM18 SHALLOW DUCT AREA REQUIREMENTS and 21ECM20 are certified for “L” -shape and “T”-shape shallow duct...
  • Page 5: Using Optional Equipment

    USING OPTIONAL EQUIPMENT 1. TWO-STAGE OR OUTDOOR THERMOSTAT 4. INTERLOCK CONNECTION (The switch must be in the M position). When the electric furnace is used in combination with another EASON ELECT Follow the directions supplied with the two-stage or outdoor device (as for example, a wood burning furnace), it is thermostat in conjunction with the furnace wiring diagram.
  • Page 6: Service Parts

    SERVICE PARTS REPLACEMENT PARTS KEY NO. PART NO. DESCRIPTION 30270032 Automatic Limit 30030006 Season Select Switch 30030025 Speed Selector Switch 30280021 Thermostat Indicator Light 10941289 Motor 1/3 HP208/230 V for 21ECM10 and 21ECM15 10941290 Motor 1/3 HP208/230 V for 21ECM18/20/23 10940080 Element Assembly 5000 W, 240 V 10940081...
  • Page 7: Wiring Diagrams

    WIRING DIAGRAMS WARNING Risk of electric shock. Disconnect power before installation, servicing, maintenance or field wiring. Replace all panels before operating. Failure to do so can result in electric shock causing severe injuries or death. Open: 93.3°C (200°F) MRHTL1 MRHTL2 Critical Characteristics HEAT 3 1.
  • Page 8 WIRING DIAGRAMS (CONT’D) WARNING Risk of electric shock. Disconnect power before installation, servicing, maintenance or field wiring. Replace all panels before operating. Failure to do so can result in electric shock causing severe injuries or death. Open: 93.3°C (200°F) MRHTL1 MRHTL2 HEAT 4 HEAT 4...
  • Page 9 WIRING DIAGRAMS (CONT’D) WARNING Risk of electric shock. Disconnect power before installation, servicing, maintenance or field wiring. Replace all panels before operating. Failure to do so can result in electric shock causing severe injuries or death. RLY PWR2 P2-3 HEAT5 Open: 93.3°C (200°F) P2-2 HEAT6...
  • Page 10: Troubleshooting

    EASON ELECT SIXTY-MONTH LIMITED WARRANTY FOR NORTRON PRODUCTS Broan-NuTone Canada (Broan-NuTone) warrants to the original consumer purchaser of Notron products that such products will be free from defects in materials or workmanship for a period of sixty (60) months from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Table of Contents