QuietCool QC48B2 Owner's Manual

8” portable evaporative cooler, belt drive 2 speed

Advertisement

48" QuietCool
Portable Evaporative Cooler
Owner's Manual
Optional Cover for storage protection.
See section 9.0 for details and a
convenient Fax Back Order form.
This Manual covers the QC48B2 QuietCool Portable Evaporative Cooler.
QC48B2 – QuietCool 48" Belt Drive 2 Speed
1

Advertisement

Table of Contents
loading

Summary of Contents for QuietCool QC48B2

  • Page 1 48” QuietCool Portable Evaporative Cooler Owner’s Manual Optional Cover for storage protection. See section 9.0 for details and a convenient Fax Back Order form. This Manual covers the QC48B2 QuietCool Portable Evaporative Cooler. QC48B2 – QuietCool 48” Belt Drive 2 Speed...
  • Page 2 WARNING Your QuietCool unit must be plugged into a fused or circuit breaker protected 20 Amp, 120 Volt, 60 Hz circuit – unless specifically manufactured for another voltage / frequency configuration. See manufacturer’s label on cooler. A ground fault circuit interrupter protected circuit is strongly recommended.
  • Page 3: Table Of Contents

    Table of Contents Introduction 1.1 Quick Start 1.2 Operate unit for 2 weeks before adding Evap-O-Matic Tablets How Evaporative Cooling Works Unpacking your new QuietCool unit Set-up your QuietCool unit 4.1 Connecting the electrical supply 4.2 Connecting the water supply Operating procedures 5.1 Filling the units reservoir with water...
  • Page 4: Introduction

    QuietCool is easy to operate – needs only tap water and electricity to operate.  QuietCool is easy to move – roll your QuietCool to the area you want to cool. QuietCool comes standard with straight and swivel / lock casters which make moving your QuietCool a breeze.
  • Page 5: Connecting The Electrical Supply

    If you have purchased our optional QR60 gallon reservoir tank – simply attach the garden hose from the tank to the cooler. Note: Do not connect to water source exceeding 60 p.s.i. – this can cause damage to your QuietCool.
  • Page 6: Adjust Water Flow

    Once your units cooling pads are saturated – then, you are ready to turn on fan and begin to feel the cooling effect from your new QuietCool. Note: After your cooling pads are broken in (typically takes 1 -2 weeks in operation) it will take less time to saturate pads for start-up.
  • Page 7: Daily Maintenance

    If you begin to detect an algae smell coming from your unit – it’s time to flush your QuietCool reservoir with fresh water. Refer to and follow the steps above in 7.2 and you will only need to remove 1 or 2 of the cooling pads from the left side of the unit to gain access to your water reservoir.
  • Page 8 Check your water flow valve first. Make sure your water flow valve is open. pads . . . QuietCool units usually operate at peak performance at 1 ¼ turns. Water supply off at main valve source. Open water valve at supply. You may wish to keep this valve open at all times.
  • Page 9: Storage

    Remove pads as described above in 7.2 and rinse pads clean with fresh water. Dry cooling pads in sunlight. Drain water reservoir completely and wipe dry. Replace dry cooling pads. Replace top angle bar to hold pads in place. Store QuietCool in dry, clean area and cover (you can order a QCCover for your unit –...
  • Page 10 List $ 48.00 each. Evapo-O-Matic Tablets for all QuietCool Portable Evaporative Coolers. Evapo-O- Matic is the chemical water treatment tablets that stops scale and calcium deposits associated with hard water. Adds life to vital cooler equipment – increases cooling efficiency and ends swampy odors.
  • Page 11 10.0 Replacement Parts All Accessories / Replacement Parts are obtainable through your local QuietCool distributor. Should a part be temporarily out of stock at your distributor he can special order it for you. You can contact the manufacturer, Quietaire Cooling Inc. directly at: Telephone: 713.228.9421 or Fax: 713.228.9425.
  • Page 12: Accessories

    11.0 Order form Fax Back Order Form Accessories and Replacement Parts For all QC48” fan blade models. For all motors, pulleys, belts, switches and fan blades call Quietaire at 713.228.9421. Accessories Part Number Description Quantity Amount Price Intake Pre-Filter – protects cooling QC48PM List $ 48.00 each pads from air-borne particles.
  • Page 13: Wiring Diagrams For The 48" Unit

    12.0 Wiring Diagrams for the 48” unit...
  • Page 14: Warranty

    Any such recommendations, opinions or advice are given and shall be accepted at your own risk and shall not constitute any warranty or guarantee of such products or their performance. QUIETAIRE COOLING INC. 505 NORTH HUTCHESON STREET HOUSTON, TEXAS 77003 TELEPHONE: 713.228.9421 FAX: 713.228.9425 Visit us online at: www.Quietaire.com Click on QuietCool...