Conversions - Summit GC2BGL Instruction Manual

Built-in ceramic gas cooktops
Table of Contents

Advertisement

Replacing Nozzles
The burners can be adapted to suit different
types of gas by fitting the nozzles that corres-
pond to the gas used. To do this, it is
necessary to remove the burner heads and
use a straight key "B", to unscrew the nozzle
"A" (see Fig. 7) and replace it with a nozzle
corresponding to the gas used.
Be sure the nozzle is seated tightly.
After making these replacements, the technician must regulate the burners
as described in Adjustments on the previous page and apply the label
corresponding to the new gas type in place of that previously applied. This
label is contained in the spare nozzle bag.
For ease of the fitter, we have prepared a table indicating the flow capacities, the
heat capacities of the burners, the diameter of the nozzles and the working
pressure for the various types of gas.
Burners
No.
Description
2
Rapid
3
Semirapid
4
Semirapid
5
Auxiliary

CONVERSIONS

2
5
Pressure,
Gas
inches water
Propane HD-5
Natural Gas
Propane HD-5
Natural Gas
Propane HD-5
Natural Gas
Propane HD-5
Natural Gas
2
4
3
5
Normal
Injector
Diameter,
1/100 mm
column
11
83
7
145
11
58
7
100
11
58
7
100
11
50
7
90
9
Fig. 7
Arrangement
of Burners
Nominal Heat
Input (Btu/h)
Min.
Max.
2400
8350
2400
8350
2050
4350
1700
4350
2050
4350
1700
4350
1200
3400
1400
3400

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gc424bgl

Table of Contents