Ardent Energy HF65R Installation And Operation Instruction Manual

Ardent Energy HF65R Installation And Operation Instruction Manual

Solid fuel

Advertisement

Box 3637, Smithers, BC V0J 2N0
INSTALLATION AND OPERATION INSTRUCTION MANUAL
PLEASE
KEEP THESE
INSTRUCTIONS
FOR FUTURE
REFERENCE
SOLID FUEL SPACE HEATER
Model HF65R
Operation
Maintenance
Installation

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HF65R and is the answer not in the manual?

Questions and answers

Dan Martin
January 24, 2025

What is the minimum clearance from the top of the stove to the ceiling?

1 comments:
Mr. Anderson
May 14, 2025

The minimum clearance from the top of the Ardent Energy HF65R stove to the ceiling is not specified in the provided information.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for Ardent Energy HF65R

  • Page 1 SOLID FUEL SPACE HEATER Model HF65R Box 3637, Smithers, BC V0J 2N0 INSTALLATION AND OPERATION INSTRUCTION MANUAL PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Operation Maintenance Installation...
  • Page 2: Table Of Contents

    In the event you wish to add optional equipment to your unit at a later date, please inform your ARDENT ENERGY dealer. The serial number of your heater should be included with your order to assure prompt and accurate service.
  • Page 3: Safety Instructions

    WEIGHT (Kg) are necessitated. (lbs.) All ARDENT ENERGY heating units are designed with double walled sides and insulated doors. This FUEL CAPACITY (liters) keeps the exterior of the units relatively cool. How- (cu ft)
  • Page 4: Operation Instructions

    Model HF65R OPERATION INSTRUCTIONS RELOADING ARDENT ENERGY units are especially designed for controllabil- Have wood on hand to load firebox. ity. With the optional thermostat kit, your house will be heated to within 1 degree Celsius of your thermostat setting.
  • Page 5: Draft Control

    Sidewall (A) 460 mm (18”) (D) 675 mm (26 1/2”) Chimney suitability is the most important factor that will influence the performance of your ARDENT ENERGY heater. If you follow Backwall (B) 360 mm (14”) (E) 470 mm (18 1/2”) these instructions your heater will perform efficiently.
  • Page 6: Chimney

    Attach the remaining end through hole in air intake assembly. (There should be a slight slack in the chain) ARDENT ENERGY heating units burn very efficiently, resulting in lower than usual flue gas temperatures. For this reason, Locate thermostat some distance from heater 3M — 6M outside installation of the chimney is not recommended.
  • Page 7: Water Heating System

    Model HF65R WATER HEATING COIL (MODEL SHW4) REPLACEMENT PARTS LIST ARDENT ENERGY heating units are designed to heat your do- ITEM QTY DESCRIPTION PART # mestic hot water during the heating season. Closer pawl 6261 The HF65 can accept one or two coils (1 per side). The coil re-...
  • Page 8: Replacement Parts Illustration

    Model HF65R Fig. 7 NOTE: RECORD YOUR MODEL AND SERIAL # HERE FOR EASY REFERENCE WHEN ORDERING REPLACEMENT PARTS. MODEL # ____________________________________________ SERIAL I# ___________________________________________ DATE OF INSTALLATION _______________________________...
  • Page 9: Warranty

    (3) years from the date received, with the exception of items listed hereafter in the "Exclusions" section. Ardent Energy Ltd., at its option, will replace, repair or cause to be repaired any part found to be defective upon inspection by an authorized Ardent Energy Ltd. representative.