IMPORTANT NOTICE:
This product is not intended to be use by children or persons in poor health without
supervision. Please read this manual thoroughly before use.
CAUTION:
Each model is design to work up to its maximum rated power load.
Please check carefully to ensure applications used are within the rated power range.
Any attempt of misuse to overload will trigger the overload protection and may cause
damage to both unit and application used. Mercury will not be responsible for any
damaged caused by misusage of the product
This manual is written for below models:
652.000UK – IMS150-12
652.001UK – IMS150-24
652.002UK – IMS300-12
652.003UK – IMS300-24
652.004UK – IMS600-12
652.005UK – IMS600-24
WARNING
Contain high voltage and high current! Do not open or
attempt to repair yourself!
652.006UK – IMS1000-12
652.007UK – IMS1000-24
652.008UK – IMS1500-12
652.009UK – IMS1500-24
652.010UK – IMS2500-12
652.011UK – IMS2500-24

Advertisement

Table of Contents
loading

Summary of Contents for Mercury IMS150-12

  • Page 1 Please check carefully to ensure applications used are within the rated power range. Any attempt of misuse to overload will trigger the overload protection and may cause damage to both unit and application used. Mercury will not be responsible for any damaged caused by misusage of the product...
  • Page 2: Product Layout

    INTRODUTION: Thank you for choosing this Modified Sine Wave Inverter. This inverter is capable of converting DC power input to AC power output that has similar output signal wave as normal domestic mains. Unlike pure sine wave inverters, modified sine wave inverter is not recommended for powering voltage sensitive or inductive equipment.
  • Page 3: Front Panel

    FRONT PANEL: ON/OFF SWITCH – rocker switch to switch unit on and off POWER INDICATOR – solid green LED indicates unit has been switched on FAULT INDICATOR – solid on or flashing red LED indicates fault has occurred, refer to fault code for interpretation USB POWER SOCKET –...
  • Page 4 Please beware, any use of cables and accessories other than the ones provided may cause damage, Mercury will not take any responsible for damage caused by use of third party accessories. For cable cross-section requirement for different models, please refer to accessory appendix at the back of this manual.
  • Page 5 For running the inverter on a DC power supply, it is important the check the current from power source is sufficient to run the inverter at full load. The required current to allow the inverter to operate at full load can be estimated from the continuous output power of the inverter and input power voltage.
  • Page 6: Safety Instruction

    24V OUTPUT – SERIES CONNECTION (voltage increase current remain) 24V OUTPUT – SERIES/PARALLEL CONNECTION (both voltage and current increase) SAFETY INSTRUCTION: Please note the following instructions should be carefully followed as any incorrect installation or misuse of the inverter may cause harm to user and damage apparatus. Do not connect any other form of input power other than DC power that is within the inverter’s acceptance range Ensure the ventilation duct on both front and back panels are clear of blockage when the inverter...
  • Page 7: Protection Features

    when in use, please discontinue use immediately and contact technician or retailer This inverter is design to be maintenance free, but requires occasional attention as dust may build up after period of time. To clean dust off, please switch off power from inverter and unplug AC plug.
  • Page 8: Troubleshooting Reference

    TROUBLESHOOTING REFERENCE SYMPTOM POSSIBLE CAUSE SOLUTIONS 1. Check the continuity of the DC power input, ensure all batteries are working or DC power supply is on. There is no DC power from 2. Check that the battery inline fuse is intact. Replace if the input terminals ON/OFF switch is blown.
  • Page 9: Warranty

    Valid receipt or bank statement to show purchase date is within last 12 months must be shown for warranty to be valid. Any unit that has been misused, altered or accidentally damaged will not be covered by warranty. Mercury will not be responsible for any damage cause as result of misconduct. SPECIFICATION: MODEL...
  • Page 10 MODEL SPEC IMS1000-12 IMS1000-24 IMS1500-12 IMS1500-24 IMS2500-12 IMS2500-24 10.8- 10.8- VOLTAGE 21.6-31Vdc 21.6-31Vdc 10.8-15.5Vdc 21.6-31Vdc 15.5Vdc 15.5Vdc EFFICIENCY Over 80% Efficiency POWER TYPE Open & Seal Lead Acid Battery, Regulated DC Alternator CONTINUOUS 1000W 1000W 1500W 1500W 2500W 2500W POWER SURGE 200% of Continuous Power for 2 sec to help starting up POWER...
  • Page 11 APPENDIX: Below table show recommended accessories specification for each model of inverter: BATTERY MODEL INPUT VOLTAGE DC INPUT CABLE FUSE CAPACITY IMS150-12 1 pair 2.5mm ≥25Ah IMS150-24 1 pair 2.5mm ≥15Ah IMS300-12 1 pair 4mm ≥50Ah IMS300-24 1 pair 2.5mm ≥25Ah...