Waterwise 9000 Use & Care Manual

Waterwise 9000 Use & Care Manual

Countertop steam distiller/purifier
Hide thumbs Also See for 9000:

Advertisement

U S E & C A R E G U I D E
Waterwise 9000
Countertop Steam Distiller/Puri
See important safeguards on pages 2 and 3
An exclamation point within an equilateral triangle
is intended to alert user to the presence of important
operating and maintenance instructions in the literature
accompanying the appliance.
A lightning bolt within an equilateral triangle is intended
to alert user to risk of injury from electric shock.
Flame and steam vapor within an equilateral triangle
is intended to alert user to risk of injury from boiling
water and/or escaping steam.
fier
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 9000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Waterwise 9000

  • Page 1 U S E & C A R E G U I D E Waterwise 9000 ™ fier Countertop Steam Distiller/Puri ® See important safeguards on pages 2 and 3 An exclamation point within an equilateral triangle is intended to alert user to the presence of important operating and maintenance instructions in the literature accompanying the appliance. A lightning bolt within an equilateral triangle is intended to alert user to risk of injury from electric shock. Flame and steam vapor within an equilateral triangle is intended to alert user to risk of injury from boiling water and/or escaping steam.
  • Page 2: Important Safeguards

    6. A short power supply cord is provided to reduce risks resulting from becoming entangled in or tripping over a longer cord. If an extension cord must be used, its marked electrical rating must be at least as great as the electrical rating of the Distiller. Electrical rating is found on bottom of Distiller. 7. To protect against fire, electrical shock, and injury to persons, DO NOT immerse power cord or Distiller in water or liquid. 8. DO NOT operate with a damaged cord or plug, after a malfunction, or if the Distiller has been damaged in any manner. Return to an authorized service facility for examination and repair. 9. This Distiller is recommended for use with potable water only. DO NOT attempt to make safe drinking water from non-potable water sources. DO NOT use briny (sea) water as this will damage certain compo- nents and will void warranty. 1 0. Operate in a well-ventilated area away from other heat sources. Provide adequate air space (at least 4-6 inches from walls or cabinets) when in use. DO NOT place on or near a hot gas or electric burner, or in a heated oven. DO NOT place, store, or stack anything on top of or against sides of Distiller while in operation. 2 Waterwise 9000 Distiller Use & Care Guide...
  • Page 3 1 6. DO NOT use appliance for other than intended use. ELECTRIC CORD STATEMENT CAUTION: Your Distiller has a short cord as a safety precaution to prevent injury or property damage resulting from pulling, tripping or becoming entangled with the cord. DO NOT allow children to be near Distiller without close adult supervision. If you must use an extension cord with Distiller, the cord must be arranged so that it will not drape or hang over the edge of a countertop or tabletop where it can be pulled on by children or tripped over. To prevent electric shock, injury or fire, the electrical rating of the extension cord you use must be the same as, or more than wattage of the Distiller (wattage is indicated on bottom of Distiller). Plug Distiller into rated voltage AC grounded electric outlet ONLY (rated voltage found on bottom of product). The cord has a three-prong plug which mates with a standard three-prong grounded wall outlet. DO NOT cut or remove third prong from plug. If an adapter is used, be sure adapter wire and wall outlet are grounded. If there is any doubt as to whether the outlet is properly grounded, check with a qualified electrician. Unplug Distiller when not in use. WARNING: Never remove the boiler while the fan motor is running, or for 30 minutes after it stops. Severe burns can result from boiling water or steam. DO NOT change position or location of distiller while it is operating or cooling. SAVE THESE INSTRUCTIONS Waterwise 9000 Distiller Use & Care Guide...
  • Page 4: How It Works

    Waterwise 9000 Production rate: 5.5 gallons per day Model Volts Hertz Watts North America 9012 120 VAC 60 Hz 750W Europe 9024 230 VAC 50 Hz 730W United Kingdom 9025 230 VAC 50 Hz 730W Southeast Asia 9026 230 VAC 50 Hz 750W 4 Waterwise 9000 Distiller Use & Care Guide...
  • Page 5: Preparing For First Time Use

    Figure B Install Filter Cup Bottle Cap Place sterilized filter cup into opening of collector/dispenser bottle. There is a label packed with replacement filter Filter Cup cups. Write in installation date as a replacement reminder. Replace Filter Cup The filter cup should be replaced every two months or after 60-80 gallons of water processed (which- Dispensing ever comes first). Replace more often Valve should the distilled water begin to have an unwanted taste or odor. Discard first gallon of distilled water as it may contain small, harmless carbon fines. Order replacement filters from the outlet where you purchased Collector/Dispenser Bottle your distiller. Waterwise 9000 Distiller Use & Care Guide...
  • Page 6 5 . Loosen steam baffle securing nut by turning counterclockwise and remove steam baffle (fig. D). 6 . Rinse boiler thoroughly before filling. The water should be drained through boiler spout. 7 . Fill boiler with ordinary tap water to bottom of four tabs in boiler opening, approximately 1 gallon (3.8 Liters). These tabs indicate the MAXIMUM FILL POINT. DO NOT OVERFILL (fig. D). 8 . Replace boiler cap by turning it clockwise until tight. 9 . Make sure gasket is installed on long end of steam baffle and that it is snug against flange (fig D). Insert long end of baffle, flat side down, into the boiler spout. Turn securing nut clockwise onto spout until tight, being careful to not cross thread. IMPORTANT: Wipe off all water deposits inside the Distiller chassis and on the outside of the boiler before each distillation cycle. 6 Waterwise 9000 Distiller Use & Care Guide...
  • Page 7 WARNING: To prevent personal injury, burn and/or scald injury, DO NOT remove boiler while “Start” button is illuminated or at any time when the boiler is hot. Always unplug Distiller from wall outlet and allow boiler to cool completely before removing it from the Distiller (at least 30 minutes). DO NOT change position or location of Dis- Figure E tiller while it is operating or cooling. Distiller 13. Place prepared carbon Chassis filter cup into opening at the top of the collec- tor/dispenser bottle. DO NOT install cap onto bottle (fig. F). 14. Replace the collector/ Boiler dispenser bottle (fig. F). Make sure the Start dispensing valve is Button securely tightened. Waterwise 9000 Distiller Use & Care Guide...
  • Page 8 NOTE: At the end of the distillation cycle (about 4.5 hours), Distiller will shut off automatically and “Start” light will go out. The fan will continue to operate for a few minutes. 15. Unplug cord from wall outlet when not in use. 16. DISCARD FIRST GALLON of distilled water as it may contain some harmless matter from manufacturing and/or packaging. 17. Rinse boiler thoroughly before refilling. IMPORTANT: Wipe off all water deposits inside the Distiller chassis and on the outside of the boiler before each distillation cycle. NOTE: The collector/dispenser bottle will not fill completely. The collec- tor was designed to hold 1 gallon of water and allow additional space so that the carbon filter does not remain in contact with the distilled water. Once distillation cycle is complete, the water bottle may be placed in refrigerator and used to dispense the distilled water. The filter cup may be left in or removed and stored in the refrigerator in a sealed plastic bag or other airtight container. Secure cap onto the bottle to avoid spilling. The cap must be opened slightly before dispensing water. It is recommended that the bottle NOT be placed in a freezer as handle may become brittle and crack. NOTE: Approximately 5 ounces (150 ml) of water will remain in boiler at the end of the distillation cycle. This feature reduces scale deposits in the boiler. WARNING: To prevent personal injury or electric shock, DO NOT immerse the Distiller, its boiler, its cord or plugs in water or other liquid. 8 Waterwise 9000 Distiller Use & Care Guide...
  • Page 9 IMPORTANT: Wipe off all water deposits inside the Distiller chassis and on the outside of the boiler before each distillation cycle. Cleaning Collector/Dispenser Bottle See page 5 for cleaning and sanitizing instructions. Replacing Carbon Filter Cup See page 5 for preparation and installation instructions. Distiller Chassis Maintenance Outside surfaces may be cleaned with common, non-abrasive household glass or appliance cleaners or warm soapy water applied to a soft cloth or sponge. The Distiller’s cooling vents (fig. G) should be vacuumed occasion- ally or cleaned with a soft brush to remove dust and debris. IMPORTANT: There Figure G are NO user serviceable Cooling parts inside Distiller. Vents Contact qualified service personnel for repair if troubleshooting tips fail (page 10). Distiller Chassis Waterwise 9000 Distiller Use & Care Guide...
  • Page 10: Troubleshooting

    Boiler cap gasket missing Replace gasket. or defective. Water leaking from Cap is on collector/dis- Remove cap from bottle Distiller. penser bottle. during distillation cycle. Dispensing valve loose. Tighten dispensing valve. No power to boiler. Boiler not fully engaged in Make sure the boiler is chassis. properly placed (fig. E). Early shut off. Electrical power interup- Press “Start” button to tion. restart. Excessive deposits in boiler. Clean boiler (page 9). Water under boiler. Steam baffle improperly Properly install steam inserted. baffle and steam baffle securing nut (page 6, #9). O-ring worn or defective. Replace o-ring. 10 Waterwise 9000 Distiller Use & Care Guide...
  • Page 11 Pet Care… pets will enjoy the same benefits people do Baby Formulas… pure enough for formulas, inhalation therapy and herbal tinctures and many other uses you’ll discover… Waterwise 9000 Distiller Use & Care Guide...
  • Page 12: Warranty Registration Card

    OWNER’S LIMITED WARRANTY Waterwise warrants, to the original purchaser, this product against defects in materials and workmanship, excluding the disposable carbon filter and gasket, for a period of one (1) year from the date of purchase. Defects or failures due to shipping/handling, improper use or maintenance, including abuse or neglect, normal wear, water condi- tions, accidents, alterations or modifications, or unauthorized repair are specifically excluded from this warranty. No dealer, distributor, agent, representative, or other person is authorized to extend or expand this warranty. Waterwise is not responsible or liable for personal injury, property damage, or incidental or consequential damages arising out of, or in connection with, the use or performance of the product or other damages with respect to loss of use, or costs of removal, instal- lation, or reinstallation. Waterwise will, at its option, replace or repair the defective part(s) without charge, provided they are returned, transportation prepaid by owner, to an authorized service facility or to the address below. Enclose a letter describing the problem, copy of dated proof of purchase, and your name, address and daytime telephone number. This limited warranty does not guarantee uninterrupted service. Repair or replace- ment as provided under this warranty is the exclusive remedy of the purchaser. This limited warranty is in lieu of all other warranties, expressed or implied, including, but not limited to, any implied warranty of merchantability or fitness for a particular use or purpose. This warranty gives you specific legal rights and you may also have other rights which vary from state to state or province to province. Outside the United States, a different warranty may apply. For details, please contact your authorized Waterwise distributor. If your distiller fails to function properly or requires service, please contact your autho- rized distributor to arrange for service and/or replacement parts. 3608 Parkway Blvd • Leesburg Florida 34748-9399 • (352) 787-5008 • Fax: (352) 787-8123 www.waterwise.com • E-mail: service@waterwise.com © 2000 Waterwise Inc Printed in USA Form 9801 Rev 02/07 •...