WARNINGS AND CAUTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE. DO NOT INSERT ANY METALLIC OBJECTS THROUGH VENTILATION GRILLS OR OPENINGS ON THE EQUIPMENT. CAUTION EXPLANATION OF GRAPHICAL SYMBOLS The lighting flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user the presence of non-insulated “dangerous voltage”...
Page 3
PRECAUTIONS: 1. Persons without technical qualifications should not attempt to operate this dome device before reading this manual thoroughly. 2. Remove any power to the dome before attempting any operations or adjustments inside the dome cover to avoid potential damage to the mechanism. 3.
IMPORTANT SAFEGUARDS 1. Read these instructions before attempting installation or operation of dome device 2. Keep these instructions for future reference 3. Heed all warnings and adhere to electrical specifications Follow all instructions 4. Clean only with non abrasive dry cotton cloth, lint free and approved acrylic cleaners 5.
INDEX 1 Product Introduction......................1 1.1 Package Contents......................1 1.2 Specification........................2 1.3 Function Description ......................3 2 Installation.........................5 2.1 DIP Switch Settings .......................5 2.1.1 Preparation ....................5 2.1.2 Address Settings...................6 2.1.3 Baud Rate Settings..................6 2.1.4 RS-485 Bus Matching Resistance ..............6 2.2 Connection........................7 3. Function Instruction......................8 3.1 Power Up Action ......................8 3.2 Basic Function .......................8 3.3 Special Function ......................9...
Page 6
Appendix Ⅲ Common Knowledge on RS-485 Bus ............23 1. Basic Feature of RS-485bus..................23 2. Mode of Connection and Terminal Resistance...............23 Appendix Ⅳ Address Code Mapping Table................23 Appendix Ⅲ Exception Handling..................26 Copyright Statement ......................27 * Indicates the functions with default protocol, it might not function by using other protocols ※...
Privacy Mask Support (only Sony, 24pcs settable) Alarm 6 Inputs and 2 outputs (Optional) OSD Menu Multiple Language (P/N customization) Operating Temperature -40°~ +60° Operating Humidity ≤95% Non Condensing Heater & Blower Auto temperature control Waterproof IP66 Power AC/DC15-28V ≤3A Lightning Protection Transient voltage 6000V Power Consumption...
Page 10
The auto focus enables the camera to focus automatically to maintain clear image. User can use manual focus to in special condition. Under the following conditions camera will not auto focus on the camera target: (1) Target is not the center of the screen; (2) Attempting to view images that are far and near at the same time;...
A-B Scan Dome circularly scan close-up real-time scene according to A-B points at setting speed in both horizontal and vertical directions. Pan Scan Dome 360°clockwise continuous scan the display scene at setting speed in horizontal direction under the condition that pitch angle remains the same. ...
2.1.2 Address Settings DIP switch SW1 is the address settings of camera. It is a 8-bit switch, each switch corresponds with 0 or 1 in the Binary code. OFF status means 0 while ON status means 1. (See illustration above) Turn on the 1st and 3rd (allocated to ON position) and get the binary code 00000101, so the correspondence address is 5.
DIP switch SW2 has a control switch of matching resistor. That the 8 bit micro-switch turn to the ON state (set as below) means having connected the matching electricity to RS-485 bus. 2.2 Connection Connection of RS485 Before connecting, please turn off the power and read carefully the instructions of all connected devices.
Fig 24 3. Function Instruction 3.1 Power Up Action <SYSTEM> <SYSTEM> PROTOCOL ATUO PROTOCOL ATUO DOME ID DOME ID COMM COMM VERSION VERSION PAN: XXX TILT: XXX DETECTING Power Up Self Testing Pan, Tilt, Camera Self-test Completion Pan action: Pan rotate in certain direction and stop in zero coordinate. ...
Deleting preset press button “clear”+”number”+”enter”. Remark: Some preset points are used tentatively for special functions. 3.3 Special Function The follow presets are predefined as special function, please shot+ preset No+ enter to enable those functions : PREST FUNCTION PRESET FUNCTION Pan scan180 º...
<MAIN MENU> <SYSTEM> <DOME> <CAMERA> <LANGUAGE> <DISPLAY> <RESET> EXIT fig 4.1.1 Get into the Menu Screen 4.2 System Information <SYSTEM> PROTOCOL AUTO DOME ID COMM 2400.N.1 VERSION EXIT Fig 4.2.1 MFG : Max 15 characters display on the screen. PROTOCOL : Display the protocol of the dome...
DOME ID : Display the dome address. COMM: Form: Baud rate. Check bit. Data bit. Start bit VERSION: Version will update along with the product upgrading Remark: Protocol, ID and COMM all can be set in menu <COMM>. 4.3 Dome <DOME>...
It is only and used to distinct from the ID of other domes. CHECK ID Distinguishing several domes with same ID and altering target ID, soft protocol and baud rate need to enter check ID in line with the device ID, otherwise altering can’t be completed. TARGET ID Target ID is available from 001 to 250.
SETTING Each guard tour includes max 16 presets. The number of the preset is from 0-64. 0 is not valid, dwell time is 1 to 60s selectable. Speed is 1 to 64 grades selectable. INIT After init., preset point, dwell time, speed will resume to default setting. RUNNING Running the present guard tour.
After deleted, the preset points display as 0. While the exact preset point information doesn’t be deleted. So it is convenient for user to select the preset point needing to be scanned. Speed and dwell time will reset as default setting. 4.3.4 Pan Scan <PAN SCAN>...
When park mode is PRESERVE ACTION status, it record previous action order(A-B scan, Pan scan, Guard tour 01, Guard tour 02, Guard tour 03). Example: Running A-B scan at first, when the action stops unexpectedly, it enters the park mode to continue to run A-B scan. PARK TIME Park time is 01~60 mins selectable.
NO.02, set it again. If needing to stop it, set mask to OFF status. If the module doesn’t support privacy mask, the screen will display the interface as Fig. 4.3.6.3. 4.3.7 Alarm (Optional) <ALARM> ALARM PATROL TIME ALARM LINKAGE ALARM 1 ALARM 2 ALARM 3 ALARM 4...
4.3.8 Advanced <ADVANCED> PWR ON ACTION MEMORY RATIO SPEED AUTO FLIP <OTHERS> EXIT Fig. 4.3.8.1 PWR ON ACTION Power on action can be set as Memory, A-B scan, Pan scan, Park action, Guard tour 01, Guard tour 02, Guard tour 03 and No action. RATIO SPEED Ratio speed can be set as ON or OFF status.
Display the information of module supported by this dome. ZOOM SPEED Zoom speed is quick and slow selectable. DIGITAL ZOOM Digital zoom is on/off selectable. FOCUS Focus is auto and manual selectable IRIS Iris is auto and manual selectable BLC is ON and OFF selectable FREEZE Video freeze is ON and OFF selectable Remark: Only if those functions are available on the present module, the user can use it.
4.6 Display <DISPLAY> SYSTEM P AND T ACTION DOME ID COMM EXIT Fig. 4.6.1 SYSTEM Video system includes NTSC and PAL. N means NTSC and P means PAL. P AND T On screen, it displays the pan and tilt degree, user can enable or disable it. ACTION On the screen, it displays the current action, such as A-B scan, Call preset, Save preset, Call park action, Pan scan etc.
Appendix Ⅰ Anti-lightning, Anti-surge This product is extremely air discharge and lightning protection with TVS tube technology, which can effectively prevent the transient lightning below voltage 3000V, surge and damages caused by other types of pulse signals. However, necessary protective measures should be made in the premise of ensuring electrical safety for outdoor installation according to the actual situation : ·Signal transmission line must be at least 50 meters far away from the high-voltage equipment or high voltage cable.
● Please use a soft enough dry cloth or other alternatives to wipe internal and external surface. ● If dirt is serious, user can use a mild detergent. Any senior furniture cleaning products can be used to clean the under cover. Appendix Ⅲ...
Page 30
Following is a dome address code mapping table to set PELCO_D: Switch Settings Address SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 ---- ---- ---- ---- ---- ---- ---- ----...
Page 31
Following is a dome address code mapping table to set PELCO_P: Switch Settings Address SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 ---- ---- ---- ---- ---- ---- ---- ----...
Appendix Ⅲ Exception Handling Issue Possible Reason Solution After power is applied, Cable harness is improperly Verify that the orientation of the connected connector input there is no action (self-test) Input power voltage is too low Verify the voltage of the input power and no video image.
Copyright Statement This copyright is merely belong to the manufacturer. Without permission, please don’t plagiarize or copy the contents of this book in any form or by any means. The company follows the policy of continuous development. Therefore, the company reserves the right to modify or improve the products described in this manual without notice.