3.3.8
Unpack replacement ballast assembly. Check voltage leads.
3.3.9
Set replacement ballast assembly down into casting. Orient
with capacitor located on side of casting marked "capacitor." Rotate
ballast plate assembly 90 degrees and gently lay the socket between
two ribs opposite the hinge. See Figure 2. Reconnect electrical
connections in accordance with tags and approved wiring practices.
3.3.10
Replace wireway cover. Tighten screw.
3.3.11
Gently move ballast plate assembly to an upright position
and place the assembly over the two keyway screws and turn
counterclockwise into position. Tighten screws.
3.3.12
Replace the refractor. Orient the refractor by locating the
markings on the refractor flange. Position the "street side" marking
toward the street and align the "rib" markings with the ribs of the
castings.
3.3.13
Place wires into wire support and reconnect electrical
connector. See Figure 3.
3.3.14
Replace correct wattage and type lamp. Close top cover
and engage latch.
3.3.15
Energize the luminaire. Check for proper operation.
4. ACCESSORIES
4.1 GV1A73 Pole Top Adaptor.
Refer to Figure 5.
4.1.1
Place and level pole top adapter on the pole. Alternate
tightening of the six set screws will assist in centering the adapter on
the tenon. Tighten the four set screws to 70 inch pounds minimum.
4.1.2
Install the luminaire.
Figure 5
5. LIMITED WARRANTY AND
LIMITATION OF LIABILITY
The Holophane limited warranty and limitation of liability is published
in the "Terms and Conditions" section of the current Holophane
buyer's guide, and is available from your local Holophane sales
representative.
GR1044
Acuity Lighting Group, Inc.
214 Oakwood Ave., Newark, OH 43055
IM-37-C, 7/02 ©2002 Acuity Lighting Group Inc.
Visit our web site at www.holophane.com
Printed in USA
IM-37-C
®

Advertisement

loading

This manual is also suitable for:

Arlington series