1. INTRODUCTION
1.1 Product Description.
The Arlington and Jefferson products are suitable for use in wet
locations and with ambient temperatures up to 25 degree C.
These luminaires are designed to distribute specific patterns of
light on the surface below. All optics including glass,
polycarbonate, and acrylic have street side orientation
embossed on the flange of the refractor.
These luminaires are designed for easy maintenance.
The lamp can be accessed by disengaging the latch and raising
the top cover.
Electrical components are mounted on an easily removable
ballast assembly plate.
®
Arlington
Jefferson Series
Arlington
®
/
Jefferson
1.2 Alternate Information Sources.
Holophane
Field Service Department
P.O. Box 3004
Newark, OH 43058-3004
(866) 759-1577
2. INSTALLATION
2.1 Tools and Material Required.
Table 1. Installation Tools and Materials
DESCRIPTION
1/8" Allen socket
1/4" nut driver or medium
flat screwdriver
Torque wrench
2.2 Installation of Luminaire without Photocontrol
Receptacle.
2.2.1
Disengage latch and open top cover. See Figure 1.
2.2.2
Remove refractor.
2.2.3
Loosen the two keyway screws and turn ballast plate
assembly clockwise to disengage. Rotate ballast plate assembly 90
degrees and gently lay the socket between two ribs opposite the
hinge. See Figure 2.
2.2.4
Loosen screw to wire way cover and remove wire way cover.
Feed supply leads from the pole through the wire way hole.
Installation and
Maintenance
Manual
GR163, GR1193
USE
Set screws (mounting)
Ballast assembly plate
and wire way cover
Set screws
IM-37-C

Advertisement

loading

Summary of Contents for HOLOPHANE Jefferson Series

  • Page 1 ® ® HOLOPHANE HOLOPHANE HOLOPHANE HOLOPHANE Arlington Installation and Jefferson Series Maintenance Manual AFTER INSTALLATION DELIVER THIS MANUAL TO OWNER Arlington Jefferson GR163, GR1193 1.2 Alternate Information Sources. IMPORTANT SAFETY INSTRUCTIONS WARNING – READ THESE INSTRUCTIONS Holophane Field Service Department CAREFULLY BEFORE ATTEMPTING TO INSTALL OR P.O.
  • Page 2 Figure 2 2.2.5 Place and level the luminaire on the pole. Position with one rib pointed toward the street. Alternate tightening of the four set screws will assist in centering the luminaire on the post capital. Tighten the four set screws to 45-50 inch pounds. 2.2.6 Wire ballast and line leads accordingly.
  • Page 3 2.3.6 3.1.2 Wire ballast and line leads accordingly. Connect incoming Disengage latch and open top cover. Refer to Figure 1. ground wire to ground wire attached to inside of wiring chamber. 3.1.3 Remove lamp. Connect incoming common wire to wire marked "COM" from ballast. 3.1.4 For photocontrol luminaire, disconnect electrical connector (On 35W high pressure sodium and 200W incandescent units,...
  • Page 4 GR1044 5. LIMITED WARRANTY AND LIMITATION OF LIABILITY ® The Holophane limited warranty and limitation of liability is published in the "Terms and Conditions" section of the current Holophane buyer's guide, and is available from your local Holophane sales representative.

This manual is also suitable for:

Arlington series