8
REFRIGERANT SYSTEM DIAGRAM
SUZ-KA25VA3.TH
Refrigerant pipe ø9.52
(with heat insulator)
Flared connection
Flared connection
Refrigerant pipe ø6.35
(with heat insulator)
SUZ-KA35VA3.TH
Refrigerant pipe ø9.52
(with heat insulator)
Flared connection
Flared connection
Refrigerant pipe ø6.35
(with heat insulator)
OCH530
4-way valve
Muffler
Stop valve
(with service port)
Discharge
temperature
thermistor
RT62
Capillary tube
ø3.0×ø2.0×240
Stop valve
(with strainer)
4-way valve
Muffler
Stop valve
(with service port)
Discharge
temperature
thermistor
RT62
Capillary tube
ø3.0×ø2.0×240
Stop valve
(with strainer)
15
15
Outdoor
Muffler
heat
exchanger
Compressor
Defrost
thermistor
RT61
LEV
Refrigerant flow in cooling
Refrigerant flow in heating
Outdoor
Muffler
heat
exchanger
Compressor
Defrost
thermistor
RT61
Capillary tube
ø3.0×ø1.8×600(×2)
LEV
Refrigerant flow in cooling
Refrigerant flow in heating
Unit: mm
Outdoor heat
exchanger
temperature
thermistor
RT68
Ambient
temperature
thermistor
RT65
Strainer
#100
R.V. coil
heating ON
cooling OFF
Unit: mm
Outdoor heat
exchanger
temperature
thermistor
RT68
Ambient
temperature
thermistor
RT65
Strainer
#100
R.V. coil
heating ON
cooling OFF