StormPro
Battery Back-Up Power Supply

General Information

Thank you for purchasing your StormPro product. To
help insure years of trouble free operation, please
read the following manual carefully.
Before Operation
Reasonable care and safe methods should be
practiced. Check local codes and requirements
before installation. This manual contains
important information for the safe use of this product.
Read this manual completely before using
this product and refer to it often for continued safe
product use. DO NOT THROW AWAY OR
LOSE THIS MANUAL. Keep it in a safe place so that
you may refer to it when needed.
Warning
Always disconnect the Unit from the receptacle
power source and battery before handling or making
any adjustments to the system.
Battery Backup Warning:
1. Risk of electrical shock this Unit has not been
investigated for use in outdoor areas.
2. Risk of electrical shock connect only to a
properly grounded, three pronged grounding
type receptacle. Under any circumstances do
not remove the grounding prong from the power
cord.
3. Do not smoke, use sparkable electrical devices
or open flame when working on this Unit!
4. Do not install Unit in locations classified as
hazardous per N.E.C., ANSI/NFPA 70 - 1999.
FAILURE TO HEED ABOVE CAUTIONS
COULD RESULT IN INJURY OR DEATH.
ATTENTION:
The StormPro Back Up System is only to be used
Register your product at
www.sumpro.com
OPERATION MANUAL
Dated: 03/15/10
Supersedes: 08/31/09
Document No.: SP-OM
with the StormPro Pump supplied with the Unit.
Using anything other than the Pump supplied with the
system will cause damage to the Unit and void the
warranty.
TOOLS NEEDED:
A pipe wrench, pliers, adjustable wrench, and
screwdriver will be needed.
BATTERY REQUIREMENTS:
Your Unit operates on 12VDC battery power when
in the power fail mode, a UL. recognized deep cycle
marine battery should be used.
We recommend:
Metropolitan Industries
Power + Battery
Model# 27-AGM
Factory Tel: 800-323-1665

Installation Instructions

1. Open the lid on the battery enclosure and place
the lower half of the battery enclosure with the
Unit in a suitable place were a 120V three prong
outlet is within reach of the receptacle power
cord, and were water will not drip or splash on
the Unit. It is also important to make sure that
the fan inlets on each side of the battery back-
up enclosure are free from obstructions. It is also
recommended that the Unit be placed on a board
or cinder block to keep it off the moist floor and
free from debris.
2. After the battery box has been put in a suitable
location the battery can be installed.
BATTERY INSTALLATION
A battery can present a risk of severe burns and injury
from high short circuit current. The following precau-
tions should be observed when working on
batteries.
1. Remove watches, rings, or other metal objects.
2. Use tools with insulated handles.
3. Do not lay tools or metal parts on top of batteries.
Metropolitan Industries, Inc.
www.metropolitanind.com
Page 1 of 11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 27-AGM and is the answer not in the manual?

Questions and answers

Summary of Contents for StormPro 27-AGM

  • Page 1: General Information

    4. Do not install Unit in locations classified as hazardous per N.E.C., ANSI/NFPA 70 - 1999. 1. Remove watches, rings, or other metal objects. FAILURE TO HEED ABOVE CAUTIONS COULD RESULT IN INJURY OR DEATH. 2. Use tools with insulated handles. ATTENTION: 3. Do not lay tools or metal parts on top of batteries. The StormPro Back Up System is only to be used Metropolitan Industries, Inc. Register your product at www.sumpro.com www.metropolitanind.com...
  • Page 2 Contact your installer or Metropolitan Industries for further assistance. DO NOT PLUG ANYTHING OTHER PUMP THAN THE STORMPRO MODEL#BA-33V PUMP SUPPLIED WITH THE SYSTEM INTO THE POWER SUPPLY. DOING SO WILL VOID THE WARRANTY! FUNCTIONS AND LIGHTS: The GREEN Power On indicator light should remain on as long as standard line power is available.
  • Page 3: Installation Diagram

    3. Plug the Pump you have plugged into the Unit directly into a live building receptacle. If the Pump 2. Once the switch is set in place and the di charge runs, recheck all the battery connections, and piping is properly installed, you can piggy back battery voltage. plug the pump and the switch into the receptacle located on the StormPro power supply. Then 4. Check sump water level to see that Pump is be- plug the power supply into the wall outlet. ing required to run. Metropolitan Industries, Inc. Register your product at www.sumpro.com...
  • Page 4: Battery Maintenance

    If electrolyte contacts the eyes, flush thoroughly maximum capacity of the Unit. and immediately with water. Seek medical attention. 8. Unit has been applied to the wrong voltage. d. Spilled electrolyte should be washed down with a suitable acid neutralizing agent. A common practice 9. The StormPro Back-Up System is used with any is to use a solution of approximately one pound (500 other pump than the StormPro BA-33V 1/3hp grams) bicarbonate of soda to approximately one pump. Metropolitan Industries, Inc. Register your product at www.sumpro.com www.metropolitanind.com...
  • Page 5 StormPro OPERATION MANUAL Battery Back-Up Power Supply Dated: 03/15/10 Supersedes: 08/31/09 Document No.: SP-OM Page 5 of 11 Warranty Coverage and Term. Metropolitan Industries, Inc. (“Metropolitan”) warrants to the original purchaser (the “Buyer”) of each Metropolitan product (the “product”), that any part thereof which proves to be defective in material or workmanship within one (1) year from date of installation or 18 months from the date of manufacture, whichever comes first, will be replaced at no charge with a new or remanufactured part, F.O.B.
  • Page 6: French Version

    StormPro OPERATION MANUAL Battery Back-Up Power Supply Dated: 03/15/10 Supersedes: 08/31/09 Document No.: SP-OM Page 6 of 11 FRench VeRSIOn Metropolitan Industries, Inc. Register your product at www.sumpro.com www.metropolitanind.com...
  • Page 7: Informations Générales

    Le soin raisonnable et les méthodes sûres devraient Nous recommandons : être pratiqués. Vérifiez les codes locaux et les Puissance métropolitaine + batterie d’industries conditions avant installation. Ce manuel contient Model# 27-AGM l’information importante pour l’usage sûr de ce produit. Téléphone d’usine : 800-323-1665 Lisez ce manuel complètement avant utilisation ce produit et se rapportent à lui souvent pour l’usage sûr Instructions d’installation continu de produit. NE JETEZ PAS OU PERDEZ CE...
  • Page 8 Entrez en contact avec votre NE BRANCHEZ RIEN L’AUTRE POMPE QUE installateur ou industries métropolitaines pour LA POMPE DE STORMPRO MODEL#BA-33V davantage d’aide. FOURNIE AVEC LE SYSTÈME À L’ALIMENTATION D’ÉNERGIE. FAIRE AINSI VIDERA LA GARANTIE ! FONCTIONS ET LUMIÈRES : La lumière VERTE d’indicateur de mise en marche...
  • Page 9: Diagramme D'installation

    STORMPRO réceptacle ajoutent l’eau au carter de vidange jusqu’à VIDANGE COMMUTATEUR ce que la pompe pompe le carter de vidange vers STORMPRO POMPE DE SECOURS le bas. Courez seulement la pompe fournie avec le système de secours de batterie pour quelques cycles. INSTALLATION DE LA POMPE DE SECOURS : La pompe de carter de vidange au niveau doit être Vous pouvez répéter ce si vous souhaitez mais lui...
  • Page 10 Si l’électrolyte entre en contact avec la peau, 7. L’unité a été appliquée aux produits dépassant la enlevez-la immédiatement. capacité maximum de l’unité. c. Si l’électrolyte entre en contact avec les yeux, 8. L’unité a été appliquée à la tension fausse. éclat complètement et immédiatement avec de l’eau. Attention médicale de recherche. 9. Le système de secours de StormPro est employé avec n’importe quelle autre pompe que la pompe d. L’électrolyte renversé devrait être lavé vers le de StormPro BA-33V 1/3hp. Metropolitan Industries, Inc. Register your product at www.sumpro.com www.metropolitanind.com...
  • Page 11 StormPro OPERATION MANUAL Battery Back-Up Power Supply Dated: 03/15/10 Supersedes: 08/31/09 Document No.: SP-OM Page 11 of 11 Garantie 1. Assurance et limite. Garanties de Metropolitan Industries, Inc. (la « métropolitaine “) à l’acheteur original (« l’acheteur “) de chaque produit métropolitain (le « produit “), que n’importe quelle partie en qui s’avère défectueuse dans le matériel ou l’exécution dans un délai d’un (1) an de date d’installation ou de 18 mois de la date de la...

Table of Contents