Instructions For Using Pump Out Adaptors - Jet-Tern Marine SELENE 40 Operation Manual

Ocean trawler
Table of Contents

Advertisement

If there is a fresh water hose on the dock, rinse the tank by adding 2 minutes of water into tank. Then re-
pump to leave the tank rinsed for the next charter. This also eliminates head odors.
NOTE: THE PUMP OUT NOZZLE IN SOME MARINAS MAY NOT BE COMPATIBLE
WITH THE SELENE PUMP OUT FITTING (e.g., ROCHE HARBOR FUEL AND PUMP OUT
DOCK). THEREFORE, IT IS ADVISIBLE TO PUMP OUT THE HOLDING TANK
WHENEVER YOU ARE AT A MARINA WITH A PUMP OUT NOZZLE THAT FITS,
IRRESPECTIVE OF THE TANK LEVEL.
IF ALL ELSE FAILS YOU CAN CONTACT PUMPMEOUT.COM, A MOBILE PUMP OUT
SESRVICE SERVING AROUND SEATTLE, PUGET SOUND AND THE SAN JUANS. 877-766-
7631 OR 425-903-3137.
#2 The tank's contents can be discharged with the MACERATOR only in Canadian waters and only in
approved discharge zones.
To operate the macerator, turn on the Macerator breaker (bottom left breaker on DC panel). Listen to the
macerator's sound. When the pitch becomes higher, the tank is empty. Discharge may be observed on
the starboard side. It should only take a few minutes to empty the tank. Be careful to not run the pump
dry as it will burn out .
There is a spare macerator stored in the top step leading to the aft cabin.

INSTRUCTIONS FOR USING PUMP OUT ADAPTORS

Various marinas will have different types of pump out nozzles on the pump out hose. As an example,
there are tapered rubber nozzles, cam-operated couplings, or rubber flange. While some may work on a
Selene without an adaptor (i.e., tapered rubber nozzle) many will not, specifically the rubber flange type
found at the Roche Harbor pump out dock.
We have provided adaptors that will, hopefully, accommodate all nozzles you may find on your trip.
When getting ready to pump out, proceed as follows:
1. Unscrew the WASTE cap on the starboard side of the boat, forward of the sliding door.
2. Determine the type of nozzle on the pump out hose. If it is the tapered rubber type, it may fit
without an adaptor (Remember YOU NEED a GOOD TIGHT SEAL for the vacuum to work.
3. If the nozzle won't work, screw the NozAll adaptor (labeled "Adaptor #1) into the deck fitting.
Insert pump out nozzle into NozAll adaptor and begin pumping.