Under no circumstances must the bowl be used by your customers as you can be held accountable for Warning any injury that may occur. Gulfstream is not liable for any injury that may occur. BASIC PRECAUTIONS SHOULD ALWAYS BE OBSERVED, INCLUDING THE FOLLOWING: 1.
SAFETY & PRECAUTION GROUNDING METHODS Because this unit must be connected to a circuit with a ground-fault circuit interrupter (GFCI), DO NOT use a grounding adapter. The use of a grounding adapter is prohibited in Canada by Part I of the Canadian Electrical Code. GROUNDING INSTRUCTIONS This appliance must be plugged into an outlet equipped with a ground-fault circuit interrupter.
Page 5
IDENTIFY YOUR FOOT-SPA Back Front Control Panel 1. Glass /Acrylic Bowl 2. Contemporary Base with height adjustable 3. Armrest 4. Folding Manicure Tray with Bowl 5. Backrest & Massage 6. Headrest Pillow 7. Seat Cushion 8. Adjustable Footrest 9. Deluxe Hand-spray 10.
Page 6
IDENTIFY YOUR FOOT-SPA SEAT OPERATION Reclining Armrest can be raised up/down Manicure tray can be folded up/down Sliding Swing out manicure tray to use accessories bowl SPA DIMENSION 36’’ Back view Swing out tray 5’’ 8’’ 30’’ 8’’ 5’’ Swing out tray 19’’...
FOOT-SPA CLEARANCE WALL CLEARANCE Wall 16’’ 37’’ Distance from center drain to the back of the spa TYPICAL FOOT-SPAS Center Center 60’’ Foot-spa #2 Foot-spa #1 16’’ 16’’ 28’’ Clearance 60’’...
INSTALLATIONS Attach The Seat to The Base Backrest installation Backrest Armrest attachment here Rod located on the bottom of the Backrest Backrest anchor located on the seat frame Lock-Latch Frame You may have to secure the seat frame on the base frame unit with nuts and bolts provided before installation of the backrest Place the backrest on the anchors located on the seat frame with both ends of the rod sit securely on the anchors as shown.
Page 9
INSTALLATIONS Cleanjet Unit Removal To remove the jet unit components. To remove the jet unit from tub/bowl. Turn the top plate counter-clockwise in the arrow direction Gently pull out the jet unit from the anchor pegs Jet Unit Components Top Plate Impeller Housing Plate &...
Page 10
INSTALLATIONS Poly Liner Installation (Glass Bowl only) Plastic Liner Heavy plastic liner Hole in the heavy plastic liner Fig.2 Thin Plastic Liner Piece of thin plastic sealed Impeller Unit to the heavy plastic liner Anchor Pegs Base Plate fixed to motor behind Glass Bowl Plastic Liner deformed by the pegs...
INSTALLATIONS Plumbing Connections ½” Hot (Red) & Cold (Blue) Fitting 3/4’’ Fitting FAILURE TO ANCHOR THE BASE MAY RESULT IN PERSONAL INJURY OR DAMAGE TO THE UNIT. DAMAGE AS A RESULT WILL VOID THE WARRANTY. 1. Discharge pump may be connected to an existing sink drain or floor drain. It can also pump up to 7 ft high, but this will increase the length of the drain time.
Page 12
INSTALLATIONS Typical Discharge Pump Installation Wall GFI Outlet Required 3/4’’ Discharge Pipe Backwater Valve sold separately Existing Drain Pipe Existing ½’’ Hot & Cold Water Supply Backwater valve sold separately Discharge Pump ½” Hot & Cold Hoses Floor Typical Gravity Sink (Direct Drain) Installation Wall GFI Outlet Required...
OPERATIONS & USE Control Panel Hand Spray Jet (On/Off) Discharge Control (Optional) Water Mixer Control Drain Control 1. To fill water: The foot-spa is provided with a single hot and cold mixing valve located on the front of your spa as shown. This is a pressure balance valve that requires you to lift the handle to start the water flow and to adjust to the temperature that is desired.
OPERATIONS & USE 9620, 9700, 9600 Shiatsu Remote Control Please refer to instruction manual for operations Power Timing TT960 Timing Power Auto Neck Upper Knead Pause Back Waist Knead Flap Shoulder Body Flap Kneading Knocking Kneading Knocking Neck Press Manual Knock Shoulder Speed...
The use of oil based products can build up in the whirlpool system causing clogging in the jets. Adherence to the above cleaning will minimize build up. Gulfstream Inc. does not recommend the use of mineral oil based products. TESTING/FLUSHING FOOT SPA After foot spa has been installed, fill tub with water just above the jets.
CLEANING & MAINTENANCE Cleaning The Magnet Jet (Step by Step) ® - Do not run Cleanjet MAX without water. This will void your warranty - Do not place two wet ends in the same bowl when cleaning Warning the jet’s strong magnets could cause injury (pins your fingers) - Do not attach two wet ends to each other.
8. Each service call from the customer will be assigned a Claim Number. The Claim Number will stay open until the problem is resolved. No dealer or other person has any authority to bind Gulfstream Inc. to changes or additions to this warranty or its products. Accordingly, Gulfstream Inc. Is not responsible for such warranties or representations.