1. INTRODUCTION
1.1 Product Description.
The Harp luminaires have been designed to distribute specific
patterns of light on the surface below. All optics have street side
orientation embossed on the flange of the refractor.
The Harp luminaire is designed for easy maintenance.
The lamp can be easily accessed by loosening a screw and
swinging down the refractor.
Electrical components are mounted on an easily removable
ballast assembly plate.
®
HARP SERIES
DAMAGE.
Installation and
2" Threaded Pipe Mount Version
1.2 Alternate Information Sources.
Holophane
Field Service Department
P.O. Box 3004
Newark, OH 43058-3004
(866) 759-1577
2. INSTALLATION
2.1 Tools and Material Required.
Table 1. Installation Tools and Materials
DESCRIPTION
USE
1/8" hex wrench
Set screws (mounting)
3/8" nutdriver or medium
flat screwdriver
Torque wrench
7/16" nutdriver or socket
1/4" nutdriver or medium
flat screwdriver
2.2 Fixture Installation.
2.2.1
Feed supply leads from the pole through the wireway hole
2.2.2
Place and level the luminaire on the pole. On units that
mount to a 3"O.D. X 4" tall tenon, alternately tighten the (6) set
screws to 10-12 foot pounds. See Figure 1. On units that mount
to a 2" threaded pipe, install the pipe nut (not supplied) used to
secure the unit.
Maintenance
Manual
GR892, GR1074
Ballast assembly plate
and wireway cover
Set screws
Ballast Assembly Cover
Ballast assembly Plate
IM-136-B

Advertisement

loading
Need help?

Need help?

Do you have a question about the HARP SERIES and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for HOLOPHANE HARP SERIES

  • Page 1: Important Safety Instructions

    ® HOLOPHANE HOLOPHANE HOLOPHANE HOLOPHANE HARP SERIES Installation and Maintenance Manual AFTER INSTALLATION DELIVER THIS MANUAL TO OWNER 3" X 4" Tall Tenon Mount Version 2” Threaded Pipe Mount Version GR892, GR1074 1.2 Alternate Information Sources. IMPORTANT SAFETY INSTRUCTIONS Holophane WARNING –...
  • Page 2 4. LIMITED WARRANTY AND refractor should be pointed toward the street. LIMITATION OF LIABILITY The Holophane limited warranty and limitation of liability is 2.2.8 Install the proper lamp type. Tighten the lamp carefully but published in the "Terms and Conditions" section of the current securely.
  • Page 3 Printed in USA IM-136-B...