  • Page 2: Safety Precautions

    Safety Precautions PREVENT FIRE ELECTRIC SHOCK, EXPOSE THIS Operating Safety PRODUCT TO RAIN OR MOISTURE. ? ? Use only the factory supplied (5VDC 8.0A) power adapter to operate the CAUTION system. RISK OF ELECTRIC ? ? Do not try to force the system’ s plug SHOCK DO NOT OPEN into a power outlet.
  • Page 3: Fcc Compliance Statement

    FCC Compliance Statement User/Installer Caution: Your authority to This digital apparatus does not exceed the operate this FCC verified equipment could Class A limit for radio noise emissions from be voided if you make changes or digital apparatus set out in the radio modifications not expressly approved by interference regulations of Canada.
  • Page 4: Table Of Contents

    Contents Safety Precautions FCC Compliance Statement System Controls and Connectors Front Panel Controls Back Panel Connectors Basic System Setup Basic Operations Full-Screen / Split-Screen Modes Video Switching Mode VCR Playback Mode Call Monitor System Configuration Understanding Menu Buttons Main Menu Dwell Time Display Formats Alarm Settings...
  • Page 5: System Controls And Connectors

    HyperView MP 1600 3 4 5 6 1. Power Switch p. 7 Button FREEZE Turns the MP1600/BMP1600 on Freezes the currently selected video and off. input’ s main monitor output or returns to normal video. ? ? Function p. 12 2.
  • Page 6: Back Panel Connectors

    S-Video VCR or time-lapse recorder. 5. Alarm Input/Output 10. Remote Interface Input Connects to the alarm input sources Connects to an MP1600/BMP1600 and output targets. compatible system control device or to a computer using an optional IBM PC interface cable.
  • Page 7: Basic System Setup

    Power Supply Make sure the power switch is off before connecting the power supply. Once the power is off, connect the factory supplied AC power supply with the DC plug on the MP1600/BMP1600 and an AC power outlet.
  • Page 8: Basic Operations

    “ 0” . Caution: Make sure the power switch is set to the off position when connecting the AC/DC adapter to the POWER IN connector on the MP1600/BMP1600 and the AC outlet. Full-Screen Mode Video Selector Full-Screen Mode...
  • Page 9: Video Switching Mode

    Basic Operations Video Switching Mode Video Switching Mode Button SPLIT/SW Multi-screen or Full-Screen Switching Mode SPLIT/SW FREEZE CALL Press the button for more than SPLIT/SW three seconds to select switching mode. Pressing the button for less than SPLIT/SW three seconds will activate the split mode. MENU ENTER Activating Full-Screen Switching...
  • Page 10: Vcr Playback Mode

    Basic Operations VCR Playback Mode VCR Playback Mode Button PLAYBACK Entering VCR Playback Mode Press the button from any video mode SPLIT/SW FREEZE CALL to display the VCR input (VCR IN) on the main monitor. The VCR output will remain unchanged.
  • Page 11: Call Monitor

    MAIN MENU MENU ENTER 2. The call light will blink to indicate that the MP1600/BMP1600 is in call monitor select mode. 3. Select the desired call monitor by pressing the number of the desired camera on the front panel.
  • Page 12 Exiting User Setup Menu Press the button for longer than MENU three seconds while in the user setup menu to exit the user setup menu. Note: The alarm will not operate while the MP1600/BMP1600 is in user setup mode.
  • Page 13: System Configuration

    FREEZE CALL MENU button are used to control the cursors and select items in each menu screen while the MP1600/BMP1600 is in user setup mode. ENTER MENU The alternative functions of these three buttons are marked below the buttons as shown on the diagram.
  • Page 14: Main Menu

    OPTIONS p. 23 Allows configuration of various options DWELL TIME p. 14 available on the MP1600/BMP1600. Causes the MP1600/BMP1600 to spend a set amount time on each camera during FACTORY DEFAULT p. 24 video switching mode. Reset all system values to the factory default values.
  • Page 15: Dwell Time

    3 SEC NEXT PAGE 3 SEC RETURN NEXT PAGE RETURN The MP1600/BMP1600 is capable of allowing each camera’ s dwell time to be set independently. Preset Mode Switching Changing Dwell Time In preset mode, dwell time can be set four 1.
  • Page 16: Display Formats

    2. Use the ? ? or ? ? button to change the . The ? ? and ? ? setting to buttons are the SPLIT/SW FREEZE buttons, respectively, while The MP1600/BMP1600 is capable of MP1600/BMP1600 is in user setup having four different preset screens mode. configured.
  • Page 17 QUAD QUAD Display Formats Screen Sizes Mode The MP1600/BMP1600 is capable of allowing each camera’ s screen size (1/4, The numbers represent the preset modes. 1/8 or 1/16) to be set independently. The four mode settings are broken down into quadrants Changing Screen Mode 1.
  • Page 18 System Configuration Display Formats Standard Split-Screen Types MP1600/BMP1600 allows selection and configuration of up to four standard custom screen displays. You may select the desired screen by pressing the Standard Split-Screen Layouts button, which will allow you to SPLIT/SW toggle through your four preset-screen settings.
  • Page 19: Full Screen

    System Configuration Custom Split-Screen Types Custom Split-Screen Layouts Quadrant Layout Custom Split-Screen Types The MP1600/BMP1600’ s screen is split up QUADRANT A QUADRANT C into four separate quadrants ( ). Each quadrant can be split up to display up to four cameras in the formats described below.
  • Page 20: Alarm Settings

    Alarm Settings Alarm Settings * ALARM * CAMERA ALARM NEXT PAGE TIME 15 SEC RETURN Each alarm input to the MP1600/BMP1600 Available Alarm Settings can be configured independently. Alarm off, Changing Alarm Settings MP1600/BMP1600 will respond to the alarm inputs.
  • Page 21: Activity Detection

    Activity Detection Activity Detection * ACTIVITY DETECT * CAMERA DETECT NEXT PAGE RETURN Available Detection Settings Each alarm input to the MP1600/BMP1600 configured independently changing its respective camera activity detection setting. Activity detect off, MP1600/BMP1600 will not respond to any Changing Activity Detection activity.
  • Page 22: Display - Date & Time Settings

    3. Select the item using the button. ENTER split-screen mode. button is the same as the ENTER button when the MP1600/ PLAYBACK FULL ID Enable or disable the display BMP1600 is in user setup mode. of camera identification in the 4.
  • Page 23: Clock / Camera Id

    CAM 4 RETURN CAM 5 CAM 6 CAM 7 CAM 8 NEXT PAGE RETURN The MP1600/BMP1600 provides up to twelve characters for camera identification. Setting the Current Date and Time Changing the Camera ID 1. Select from the CAMERA ID MAIN MENU 1.
  • Page 24: Advanced Configuration

    MAIN MENU nine-camera recording. You may view as many cameras as you wish in mode, LIVE Note: The MP1600/BMP1600 has a pre- but the MP1600/BMP1600 will only record selected password: 1227. the pre-selected number of cameras. To access the locked...
  • Page 25: Event Log / Factory Default

    ENTER ENTER the same as the button when log. PLAYBACK the MP1600/BMP1600 is in user setup mode. Activity Detect 3. The menu screen will disappear When enabled, alarms triggered by activity momentarily and then reappear.
  • Page 26: Video Gain

    MP1600/BMP1600. However, in certain installations or with the use of non-standard video equipment, it is possible the MP1600/BMP1600 will receive ADJUST unusually strong or weak input signals. In V GAIN most conditions, the MP1600/BMP1600 can stabilize video input signals.
  • Page 27 Use the ? ? or ? ? button to increase or decrease the gain. The ? ? and ? ? buttons are the SPLIT/SW FREEZE buttons, respectively, while MP1600/BMP1600 is in user setup mode. Exiting the Adjustment Screen Press button to exit. ENTER MENU These are the...
  • Page 28: Vcr Playback

    VCR Playback VCR Playback Mode Enabling VCR Playback Button PLAYBACK Press the button from any video PLAYBACK mode. The VCR input (VCR IN) will be displayed on the main monitor. The VCR SPLIT/SW FREEZE CALL output will remain unchanged. Returning to Live Mode MENU ENTER Press the...
  • Page 29: Bypass Mode

    By entering VCR bypass mode, the actual video images being recorded by the MP1600/BMP1600 can be monitored. Due to the fact that the MP1600/BMP1600 records either 9 or 16 cameras at once by switching rapidly from one camera to the...
  • Page 30: Tracking Adjustment

    Tracking Adjustment Tracking Adjustment ADJUST FOR VCR The MP1600/BMP1600 allows you to Tip: If you see a line or noise between enhance the tracking capabilities of certain screens during playback, use the ? ? or VCRs that do not conform to standard...
  • Page 31: Alarm Setup

    Alarm Setup Alarm Setup and Installation N.O. N.C. The MP1600/BMP1600 provides an interface to external alarm inputs and outputs through a 25-pin D-SUB connector on the rear panel. Authorized dealers supply a mating connector to this for the MP1600/BMP1600. Pin Definitions 1 to 16 Alarm inputs for each corresponding camera.
  • Page 32 Alarm Setup Typical Alarm Configuration Diagram Alarm Input Type The MP1600/BMP1600’ s innovative design allows it to auto-detect the alarm input type; therefore, either a normally open or normally closed type of alarm device can be used with the MP1600/BMP1600.
  • Page 33: Remote Interface

    6-conductor cable that is terminated with a 6-conductor RJ45 cable. With its use of the industry standard RS232 protocol, the MP1600/BMP1600 can be interfaced to any system that supports an RS232 interface, although optional software is required.
  • Page 34: Command Set

    Remote Interface MP/BMP1600 Series Remote Interface Command Set Command Set Main Secondary Functions Code Code Main Secondary Functions Set Main Monitor output to CAM1 Code Code Set Main Monitor output to CAM2 . 0 1 Set Call Monitor output to CAM1 Set Main Monitor output to CAM3 .
  • Page 35: Specifications

    Specifications Video Inputs Video Standards NTSC or PAL (depending on model) Signals Video Inputs Composite, 1.0V P-P, 75 ohms terminated (16-channels) VCR Input Composite, 1.0V P-P, 75 ohms terminated Components, S-Video Standards, 75 ohms terminated Video Outputs Video Standards NTSC or PAL (depending on model) Signals Loop-back Active, Composite, approx.