Download Print this page

Amtrol Pre-Pressurized Water System Tanks WELL-X-TROL Brochure & Specs page 6

Professional pre-pressurized water system tanks

Advertisement

WELL-X-TROL Professional
residential
In-Line Models
Stand Models
Underground Models
models
Dimensions
Model
Diameter
Height
No.
(ins)
(ins)
WX-101
8
12 5/8
WX-102
11
15
WX-103
11
22 1/4
WX-104
15 3/8
17 3/4
WX-200
15 3/8
22
Precharge Pressure for WX-101 & WX-102 is 20 PSIG and Sys. Conn. is 3/4" NPTM.
Precharge Pressure for WX-103 is 30 PSIG and Sys. Conn. is 3/4" NPTM.
Precharge Pressure for WX-104 and WX-200 is 30 PSIG and Sys. Conn. is 1" NPTM.
Maximum Working Pressure is 125 PSIG and Maximum Working Temperature is 200° F.
WX-101 and WX-102 models available with Ultra TUF-KOTE
Dimensions
Model
Diameter
Height
No.
(ins)
(ins)
WX-104-S
15 3/8
19 1/4
WX-201
15 3/8
23 7/8
WX-202
15 3/8
31 5/8
WX-202XL
15 3/8
38 1/4
WX-203
15 3/8
46 1/2
WX-205
22
29 5/8
WX-250
22
36
WX-251
22
46 3/4
WX-255
22
56 3/8
WX-252
22
62 1/4
WX-302
26
47 1/4
WX-350
26
61 7/8
Precharge Pressure for WX-104-S thru WX-203 is 30 PSIG and Sys. Conn. is 1" NPTF.
Precharge Pressure for WX-205 thru WX-350 is 38 PSIG and Sys. Conn. is 1 1/4" NPTF.
Maximum Working Temperature is 200° F. Maximum Working Pressure for all models except WX-252 is 125 PSIG.
Maximum Working Pressure for WX-252 is100 PSIG.
All models available with Ultra TUF-KOTE
All models except, WX-104S, WX-201, WX-252 are available with Pro-Access.
Dimensions
Model
Diameter
Height
No.
(ins)
(ins)
WX-200-UG
15 3/8
22
WX-202-UG
15 3/8
30
WX-250-UG
22
33 3/8
WX-251-UG
22
44 1/8
Precharge Pressure for WX-202-UG is 30 PSIG and Sys. Conn. is 1" NPTF Coupling.
Precharge Pressure for WX-205-UG and WX-251-UG is 38 PSIG and Sys. Conn. is 1 1/4" NPTF Coupling.
Maximum Working Pressure is 125 PSIG and Maximum Working Temperature is 200° F.
Total
Max.
System Drawdown
Volume
Accept.
20/40
30/50
(gals)
Factor
(gals)
(gals)
2.0
0.45
.8
4.4
0.55
1.8
1.5
7.6
0.42
3.1
2.6
10.3
1.00
4.1
3.5
14.0
0.81
5.6
4.8
TM
exterior coating option.
Total
Max.
System Drawdown
Volume
Accept.
20/40
30/50
(gals)
Factor
(gals)
(gals)
10.3
1.00
4.1
14.0
0.81
5.6
20.0
0.57
8.0
26.0
0.44
10.5
32.0
0.35
—-
34.0
1.00
13.7
44.0
0.77
17.7
62.0
0.55
24.9
81.0
0.41
32.6
86.0
0.39
34.6
86.0
0.54
34.6
119.0
0.39
47.8
TM
except WX-104-S, WX-201, and WX-252.
Total
Max.
System Drawdown
Volume
Accept.
20/40
30/50
(gals)
Factor
(gals)
(gals)
14.0
0.81
5.6
20.0
0.57
8.0
44.0
0.77
17.7
62.0
0.55
24.9
Shipping
40/60
Wt. (Vol.)
(gals)
lbs (cu ft)
.7
.6
5 (0.6)
1.3
9 (1.2)
2.2
15 (1.8)
3.0
20 (2.6)
4.1
22 (3.3)
Shipping
40/60
Wt. (Vol.)
(gals)
lbs (cu ft)
3.5
3.0
23
4.8
4.1
25
6.8
5.9
33
8.8
7.6
36
10.9
9.4
43
11.6
10.0
61
15.0
12.9
69
21.1
18.2
92
27.5
23.8
103
29.2
25.3
114
29.2
25.3
123
40.5
35
166
Shipping
40/60
Wt. (Vol.)
(gals)
lbs (cu ft)
4.8
4.1
22
6.8
5.9
30 (4.9)
15.0
13.0
60 (9.8)
21.1
15.3
83 (13.9)

Advertisement

loading

This manual is also suitable for:

Well-x-trol wx-101Well-x-trol wx-102Well-x-trol wx-103Well-x-trol wx-104Well-x-trol wx-200Well-x-trol wx-104-s ... Show all