Electro Industries HE-E-**-21 Series Installation & Operating Instructions Manual

He-e-**-21 series

Advertisement

Quick Links

Installation & Operating Instructions
Application
Special non-WarmFlo, non-heat pump, strip heat elements only, full kW turn-on from stat W input.
ECM™ blower speed will have to be setup for full kW rating.
Heat/cool conventional roomstat applies.
DO NOT DESTROY THIS MANUAL. PLEASE READ CAREFULLY AND KEEP IN A SAFE
PLACE FOR FUTURE REFERENCE BY A SERVICE TECHNICIAN.
Drawings: NH808
NH809
NS803
EC001
02/14/2006
Electric Furnace
HE-E-**-21 Series
NI806

Advertisement

Table of Contents
loading

Summary of Contents for Electro Industries HE-E-**-21 Series

  • Page 1 Electric Furnace Installation & Operating Instructions HE-E-**-21 Series Application Special non-WarmFlo, non-heat pump, strip heat elements only, full kW turn-on from stat W input. ECM™ blower speed will have to be setup for full kW rating. Heat/cool conventional roomstat applies.
  • Page 2: Table Of Contents

    Table of Contents Configurator Inlet Cabinets General Comments Application Installation Requirements Mechanical Installation Electrical Installation Setup or Programming Operation Indicators Replacement Parts NH808 Drawings Included: NH809 NS803 EC001 02/14/2006 NI806...
  • Page 3: Configurator

    Configurator HE-T-KW-CW Type Cabinet Width H, A, E, N 21 = 21” (see below) 24 = 24”* kW Size 10 = 9.6 kW 15 = 14.4 kW 20 = 19.2 kW* 25 = 24 kW* 30 = 28.8 kW* Type All models –...
  • Page 4: Inlet Cabinets

    Inlet Cabinets Factory optional cabinets can be configured with this Electric Furnace. Typically these are designed for upflow applications; however, the heat pump coil cabinet could be used in other positions. Side Entry, Filter Cabinet Return air can be ducted into either side, 15-⅜” x 19”...
  • Page 5: General Comments

    For upflow and horizontal standard air conditioning applications, the A-coil is mounted at the blower outlet with field provided plenum or manufacturer’s case coil. All models contain GE ECM™ Series 2.3 blower motors. The special Electro Industries interface board allows hookup for heat/cool conventional or basic heat pump room thermostat. Blower speed setup and WarmFlo sensor control are separate for cooling and heating (unique).
  • Page 6: Application

    Installation Checkout Attached to this manual is a warranty certification and checkout procedure. This must be completed and returned for warranty coverage. This is the responsibility of the contractor or company which “sold the job” and is assuming responsibility to the end customer. Warranty Statement See the last page of this manual for detailed limited warranty coverage explanation.
  • Page 7 Specification Chart Model Number HE-E-10-21 HE-E-15-21 HE-E-20-21 Cabinet Width 21” 21” 21” kW rating Btu/h 34000 51000 68000 Voltage/Phase 240/1 240/1 240/1 Circuit Breaker 1-60, 1-30 2-60 Amps per CB 42, 21 42, 42 Source Feed Elements Relays Heat CFM* 600 (LO) 900 (M) 1200 (HI)
  • Page 8: Installation Requirements

    CSA/us certification label, and manufacturer product liability. Electro Industries, Inc., cannot be held responsible for field modifications, incorrect installations, and conditions which may bypass or compromise the built-in safety features and controls.
  • Page 9: Mechanical Installation

    Mechanical Installation Clearances and Accessibility Zero clearance is allowed on all sides for combustible materials. However, 36” should be allowed at the front for operation, maintenance, and service. To reduce the risk of rusting and appearance, do not install the unit directly on the ground or on a floor that is likely to be wet.
  • Page 10 Whether this unit is sitting on or attached to an inlet cabinet, field designed inlet cabinet, or horizontal supports; verify proper support and mechanical strength is provided within the system installation. Rubber isolation pads should be used where possible to reduce sound and vibration transmission. WARNING WHEN HANGING THIS UNIT, THERE MUST BE UNDER SUPPORTS WHICH DISTRIBUTE THE HANGING CHAINS ACROSS THE SURFACE OF THIS UNIT, DO NOT SIMPLY DRILL A HOLE...
  • Page 11 Horizontal, Air Conditioning Similar to upflow above, the air conditioning coil is positioned at the blower outlet. Depending upon the coil type and drip pan it is positioned in a field constructed plenum as required. As horizontal, the return air would enter the blower end of the cabinet with a typical packaged 20” x 20” filter cabinet.
  • Page 12: Electrical Installation

    Electrical Installation WARNING TO AVOID THE RISK OF ELECTRIC SHOCK OR DEATH, WIRING TO THE UNIT MUST BE PROPERLY GROUNDED. FAILURE TO PROPERLY GROUND THE UNIT CAN RESULT IN A HAZARD LEADING TO PERSONAL INJURY OR DEATH. Line Voltage The nameplate and/or Installation and Operating Manual specification page provides kW rating and operating current requirements for each specific model.
  • Page 13: Setup Or Programming

    Cooling, Special Dehumidification The BK tab and the BK peg jumper provide the industry standard 12% blower speed reduction to “pull out” additional moisture from the air. Provide an external humidistat between BK and R and pull or permanently disconnect the BK jumper. With the BK terminal at 0 volts the 12% blower speed reduction is activated.
  • Page 14 Electric Furnace Control – Inside View, Right Board Green, next to Fuse 24-volt power connected and fuse good. Red, next to W Call for electric heat, also represents the input signal (yellow wire) to the WarmFlo control board. Green, Cool Conventional H/C stat has an active Y function or heat pump stat reversing valve is in the cool mode (will depend upon proper setup with RV logic jumper).
  • Page 15: Replacement Parts

    Replacement Parts @HEIBG6707 PCB Electric Furnace ECM™ Motor H/C and HP Stat @EMD3I6600 PCB EM DI 3-Stage 5850 Motor ½ HP ECM™ GE 5541 Transformer 120/240:24 40VA 4038 Triac SSR 50-amp 24VDC 5127 Relay NO 25A@277 24VDC Coil 6630 Limit O-150/O-180 25A@240V ST-CLSD 5636 Limit O-135/C-120 25A@240V DP-CLSD 6615...
  • Page 23 TWENTY YEAR (20) LIMITED WARRANTY ON SPIN FIN ELEMENTS Electro Industries, Inc. warrants that the spin fin elements of its products are free from defects in materials and workmanship through the twentieth year following date of installation. If any spin fin elements are found to have a manufacturing defect in materials or workmanship, Electro Industries will replace them.
  • Page 24 ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY DISCLAIMED WITH RESPECT TO ALL PURCHASERS OR OWNERS. ELECTRO INDUSTRIES, INC. IS NOT BOUND BY PROMISES MADE BY OTHERS BEYOND THE TERMS OF THESE WARRANTIES. FAILURE TO RETURN THE WARRANTY CARD SHALL HAVE NO EFFECT ON THE DISCLAIMER OF THESE IMPLIED WARRANTIES.

This manual is also suitable for:

He-e-10-21He-e-15-21He-e-20-21

Table of Contents