Ultra-air DEH 3000R Installer's & Owner's Manual

Ultra-air DEH 3000R Installer's & Owner's Manual

Dehumidifier & ventilation system controller

Advertisement

INSTALLER'S & OWNER'S MANUAL
DEH 3000R
HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER
DEH 3000R
Part No. 4028407
Dehumidifier & Ventilation System Controller
4201 Lien Rd Madison, WI 53704
TOLL-FREE 1-800-533-7533
www.thermastor.com
sales@thermastor.com
© 2008 Therma-Stor LLC • Manual P/N TS-506d 12/12

Advertisement

Table of Contents
loading

Summary of Contents for Ultra-air DEH 3000R

  • Page 1 INSTALLER’S & OWNER’S MANUAL DEH 3000R HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER DEH 3000R Part No. 4028407 Dehumidifier & Ventilation System Controller 4201 Lien Rd Madison, WI 53704 TOLL-FREE 1-800-533-7533 www.thermastor.com sales@thermastor.com • • • © 2008 Therma-Stor LLC • Manual P/N TS-506d 12/12...
  • Page 2: Table Of Contents

    Common 2. Installation Normally Closed OFF-Detect Install the DEH 3000R remote sensor in a central area of the structure where it will sense the relative humidity of the Damper Dehumidifier structure accurately. Do not install the remote sensor where it...
  • Page 3: Wiring

    WARNING! provides the ability to control fresh air ventilation using DO NOT ALLOW THE YELLOW the ventilation timer function of the DEH 3000R and WIRE FROM THE ULTRA-AIRE DEHUMIDIFIER TO CONTACT the terminal labeled “DMP” on the DEH 3000R (See THE RED OR WHITE WIRES FROM THE ULTRA-AIRE Section 3.8).
  • Page 4: Dehumidifier, Activate/De-Activate With A/C Unit

    (usually Black) must be attached to the "COM" sensor 3. Run a wire from the Red terminal on the thermostat to the terminal between "ON-D" and "OFF-D" on the DEH 3000R. TO A/C NO (Normally Open) terminal on the DEH 3000R.
  • Page 5: Testing

    After checking the wiring, this short test will confirm proper vent mode to “CLOSED”. hook-up. WARNING! 1. Install front cover of the DEH 3000R; connect the top first, DO NOT MAKE ANY OTHER then the bottom. CONNECTIONS OR TRANSFORMER DAMAGE MAY RESULT.
  • Page 6: Operation

    4. Press the “CLOCK” button again and AM or PM will flash. leave the control alone and don’t touch any buttons for 10 Use the “RH” buttons to change the value. DEH 3000R Dehumidifier & Ventilation System Controller Installation, Operation & Service Manual...
  • Page 7: Adjusting The Relative Humidity Setpoint

    50% relative humidity. recirculation. The relative humidity “SETPOINT” (desired RH to be “AUTO” – Indicates the fan will run when the DEH 3000R calls maintained) operates the dehumidifier function of the Ultra-Aire for dehumidification or ventilation. If the control has not called dehumidifier.
  • Page 8: Damper Operation And Ventilation, Manual (Hold) Mode

    The ventilation indicator “O” will be displayed whenever the unit is ventilating. The fan operation indicator “O” will also be lit. The DEH 3000R will operate fresh air ventilation according to There are three damper operation modes: your ventilation program. The control needs to be programmed 1.
  • Page 9: Temperature Cutout Programming

    Some conditions may introduce enough “CLOSED FOR” setting. Using the up/down “RH” buttons, heat to drive household temperatures up. The DEH 3000R change the duration that the damper will remain closed temperature cutout feature disables all Ultra-Aire operations if between ventilation cycles.
  • Page 10: Deh3000R

    5.0 DEH3000R — Remote sensor option. This section is applicable only to customers who have purchased a remote sensor package. The standard DEH 3000R controller does not offer remote functionality. 5.1 Remote Sensor Usage limit sensor distance. Thicker gauges will not work with splice connectors provided.
  • Page 11: Warranty

    Limited Warranty. Therma-Stor, LLC (“Therma-Stor”) warrants Customer Responsibilities. As a further condition to obtaining as follows: (i) the DEH 3000R (“Product”) will be free of material warranty coverage hereunder, the Customer must send a valid defects in workmanship or materials for a period of three (1) year warranty claim to Therma-Stor such that Therma-Stor receives (“One-Year Warranty”) following the date of initial purchase of such...
  • Page 12: Part # (P/N)

    Phone: 608-222-5301 • Fax: 608-222-1447 electronic or mechanical, for any purpose, without the express written permission www.thermastor.com • sales@thermastor.com of Therma-Stor LLC. © 2007 Therma-Stor LLC. All rights reserved. DEH 3000R Dehumidifier & Ventilation System Controller Installation, Operation & Service Manual...

Table of Contents