Set Up Flow Chart ........2 . Systems Information 1.1 Set All Default ..........3 1.2 Version Information .........3 . Systems Setting 2.1 Interfaces ...........4 2.1.1 Keyboard Wedge Setting .......5 2.1.2 RS-232 Communication Parameters ...10 2.2 Scanning Mode ..........14 2.3 Beep Setting...........17 2.4 Character Setting ..........18 2.5 Others Setting ..........20 .
Page 3
Barcode Scanner Install Flow Chart Scan the barcode of “Start Configuration” Reset the parameter Scan the necessary barcode meet application Appendix Scan two digits (HEX) in the Appendix A to be an ASCII code Scan the “END” barcode Scan the barcode of “End Configuration”...
Page 13
Start Configuration Character Parameter None (CR+LF) STX/ETX End Configuration - 13 -...
Page 14
2.2 Scan Mode Trigger Mode Press the trigger and start to scan. The scan will be end once you loose the trigger or decode the barcode. Repeat the action to start the next decodes. Auto Power off Mode Press the trigger and start to scan. The scan will be end once the time is up or decode the barcode.
Page 15
. Timeout Set-Up Scan the barcode of “Continuous/Timeout OFF Mode” Scan 2 digits of the ASCII code of the Appendix Scan the “End” of the Appendix A Scan the End Configuration to end the procedure The settings unit is a second. Ex:0*40 stands for 1 minute The Timeout Default is 0*B4, about 3 minutes - 15 -...
Page 16
Start Configuration Scan Mode Trigger On/Off Trigger On/Good read off Continuous/Trigger Off Testing Continuous/LED always On Continuous/Timeout Off Flash On Continuous/No Trigger End Configuration - 16 -...
Start Configuration 2.3 Beep Setting Buzzer Frequency (00-0A-10H) Buzzer Beep Tone (00-05-10H) Power Up Tone (OFF) Good read Beep (OFF) End Configuration - 17 -...
Page 18
Character Installation The first and last character: You can put 10 ASCII at most in front of the barcode data. When the installation is “0” that means you don’t need to add the first and last character. Please find the format as below: The First Character Barcode...
Page 19
Scan the “End Configuration”. Repeat the same process to the G2 character insertion position. Scan the “End Configuration”. Code Transmission: If your application needs to transmit the code (barcode type ID), you have to set “ON” for this feature and the format is ID + Barcode data.
Page 20
Start Configuration Preamble Setting (00) Postamble Setting (00) Character Insertion G1(00) G2(00) Character Insertion Position G1(00) G2(00) Code ID Transmission (OFF) End Configuration - 20 -...
Start Configuration 2.5 Others Setting Verify Scanning Double (Single) Bar Space Setting Bar Low (Bar High) Laser Data Scan Speed Up End Configuration - 21 -...
Start Configuration 3.12 China Post Code Reading (OFF) Code ID 00H 51(20-7EH) Verify Checksum (OFF) Transmit Check Character (OFF) End Configuration - 44 -...
Page 45
Start Configuration China Post Code Truncate Leading Digit 00H (00-50H) Truncate Last Digit 00H (00-50H) Min. Length 00H (00-50H) Max. Length 50H (00-50H) Select Insertion Code 00H (00-02H) End Configuration - 45 -...
Page 46
Start Configuration 3.13 MSI/Plessey Reading (OFF) Code ID 52H (20-7EH) Verify Checksum MOD 10 (OFF) MOD 10/10 MOD 11/10 End Configuration - 46 -...
Need help?
Do you have a question about the BLASTER and is the answer not in the manual?
Questions and answers