Page 1
INSTALLATION & OWNER’S MANUAL ALL IN ONE Type Air-source Heat Pump Water Heater Thank you very much for purchasing our product, Before using your unit , please read this manual carefully and keep it for future reference.
Page 3
WARNING This unit is required reliable earthing before usage,otherwise might cause death or injury Please ask skilled service persons for reliable earthing connection Your safety is the most important thing we concerned !
Page 4
PARTS NAMES Air Outlet Air Inlet Top Cover Filter Evaporator Electronic Control Box Fan Assy Junction Box Cover Compressor Front Cover Display Rear Cover Junction Box Cove r P T V alve Anode Rod W ater Outlet Front Decorative Board T CO Cove r (Electric Heater) Solar Sensor...
W ARNING CONTENTS PAGE Ask the professional installer for installation of the air source PRECAUTIONS..................heat pump water heating units,improper installation may result in water leakage, electric shock, or fire. ACCESSORIES..................INSTALLATION LOCATION..............Ask the professional service person for the repair and maintenance.
2. ACCESSORIES CAUTION The earth pole of terminal must be earthed,and the rated T able . 2-1 current should be more than 10A. Make sure that power Accessory Name Qty. Sharp Purpose supply terminal and power supply plug are dry enough and have a good connection.
4. INSTALLATION Place like kitchen where oil permeates. Place where strong electromagnetic waves exist. WARNING Place where flammable gases or materials exist. Place where acid or alkali gases evaporate. Ask your supplier to install the air source heat pump water heating units.
Pipeline Connection Explanation Installation of the water inlet or outlet pipes: The spec of the water inlet or outlet thread is RC3/4” (internal thread). Pipes must be heat-resistant and durable. 650 mm Installation of the pipe for PT valve: The spec of the valve connecting thread is RC3/4”...
Note: Upon connect canvas, portion airflow and 6. DUCT CONNECTION WAY capacity in heat pump system will lose in the system. Air inlet without canvas , air outlet connect to canvas. Air inlet and outlet no need to connect with canvas A≤10m Air outlet Air inlet...
Filter installing at the main unit inlet. In terms of the main unit NOTE connect with canvas, filter in there must be put forward to the air inlet of duct. (Fig.6-7/6-8) Upon connect canvas, portion airflow and ΦD capacity in heat pump system will lose in the system. oulet inlet For the case of main unit connect with canvas, the diameter of...
Page 11
7.1 Specifications of Power Supply T able . 7-1 M ode l N a m e R S J - 35 / 300 RDN 3-B WARNING P o w e r S upp l y 220-240V~50Hz Just to be on the safe side, the unit must installed an M I i n .
8. OPERATING INSTRUCTION 8.1 Operation steps Before using this unit, please follow the steps below. Water Affusion: If the unit is used for the first time or used again after emptying the tank, please make sure that the tank is full of water before turning on the power. Method: see Fig.7-1 Open the cool water inlet and...
Page 13
8-2 Operation steps Water temp. indicator: When the actual water temp. ⑧ exceeds 40℃, it lights up. OUTLET TEMP indicator: It displays water temp. 1 Control Panel Explanation ⑨ of the upper part of the tank, which can be used. It always lights.
Page 14
Lock and Unlock In order to prevent wrong operation, a special lock function has Press the “UP” and “DOWN” key, you can been designed. If there is no operation for 1min, the unit will be adjust the hour. locked automatically, and display the lock indicator . When the unit is locked, no keys can be operated.
Page 15
Press the “UP” and “DOWN” key, you can Press the “UP” and “DOWN” key, you can adjust the hour. Increase or decrease the water temp. Fig.8-9 Press the TIME ON key again and wait about 10s, flashing stops and ON TIMER When the set temp.
Page 16
Press the TIME ON key again, the minute Stop operation for about 10s, flashing digit stops flashing and the hour digit starts. stops and TIME ON+TIME OFF set is finished. TIME Fig.8-13 Press the “UP” and “DOWN” key, you can Cancel: adjust the hour.
Page 17
Warning Code of disagree The light will glitter in error with heat pump mode TEMP-SET ALARM Fig.8-16 In case of continual 20 hours when in the season ambient Press CANCEL key to stop the buzzer. temperature doesn’t meet for the heat pump operation requirement (absent from the range -7~43℃) , “LA”...
9. RUNNING AND CAPABILITY Table.8-2 Display Malfunction Description 9.1 Trial Running Error of sensor T5U Before running, please check the following items first: Error of sensor T5L Correct installation of the system; Tank and Wired Controller communication error Correct connection of pipeline and wiring; Evap.
Page 19
E-heater Mode: In this mode, the compressor and the fan motor will not run but the e-heater work only. NOTE (Water outlet temp. range 38~60℃,running ambient -30~43 When self-protection happens, cut the power supply manually ℃). and restart after the error resolved. NOTE In the E-heat mode, only half tank of water, i.e.
10.2 Non-error Malfunction 10. MAINTENANCE 3-min Protection With the power supplied, an immediate restart after the shutting 10.1 Maintenance down will have to wait 3 min as to protect the compressor. Check the connection between power supply plug and socket If self-protection happens and the system stops, check : and ground wiring regularly;...
11. SPECIFICATIONS Table. 11-1 Model RSJ-35/300RDN3-B Mode Economy Mode Hybrid Mode E-heater Mode Water-heating cap. 3000W 3000W 3000W Rated power/AMPS 3000W/13.0A 4300W/18.7A 1500W/6.5A Power supply 220-240V~ 50Hz Operation control Auto/Manual startup, error alarm, etc High-pressure Protector, Over-load Protector, Protection Temp Controller&Protector, Electric Leakage Protector, etc Compressor power 850W E-heater power...
Page 22
GIJÓN Figueres GIRONA Barberà LOGROÑO LLEIDA Terrassa Mataró St.Boi Badalona VALLADOLID BARCELONA ZARAGOZA L'Hospitalet Vilanova i la Geltrú REUS TARRAGONA MADRID CASTELLÓN VALENCIA GANDÍA BADAJOZ CIUDAD REAL ALBACETE PEDREGUER PALMA DE SALVADOR ESCODA S.A. ® ALICANTE MURCIA MALLORCA CÓRDOBA JAÉN HUELVA CARTAGENA Oficinas y Central Ventas:...
Need help?