VProtect VPTZ500 User's Manual And Operating Instructions

Indoor spreed dome

Advertisement

Quick Links

V
P
r
o
t
e
c
t
V
P
r
o
t
e
c
t
I
n
d
o
o
r
S
p
e
e
I
n
d
o
o
r
S
p
e
e
User's Manual
Operating Instructions
V
P
T
Z
5
0
0
V
P
T
Z
5
0
0
d
D
o
m
e
d
D
o
m
e
and

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VPTZ500 and is the answer not in the manual?

Questions and answers

Summary of Contents for VProtect VPTZ500

  • Page 1 User’s Manual Operating Instructions...
  • Page 2 When connecting to the power source, please follow all electric safety standards and only use the power supply designated for this device. The VPTZ500’s RS-485 and video signal uses TVS technology to protect it from strong electric surges. This technology prevents damage to the device resulting from impulse signals such as lightning strikes or surges under 500W power.
  • Page 4: Technical Data

    The advanced stepping motor technologies enable the dome to rotate smoothly, respond sensitively and aim precisely. VPTZ500 dome camera has memorizing function when the power cuts off, can auto resume to previous working status before the power cuts off. Use the high-performance VPTZ500 “When it Counts.”...
  • Page 5: Setting, Installation, Connection

    Dwell time at preset position 1-60s available Cruise Tour: 8 group Cruise Points Qty per cruise group 16 preset positions 2.2. Camera Parameter for Intelligent High-speed Dome: VPTZ500 (Built in SONY Camera). Mode ¼” Sony Exview (Day/Night) CCD Sync Internal/ external Scan...
  • Page 6 3.1.1 VPTZ500 Dome Camera Address Setting The address code for the VPTZ500 should be properly set before use to ensure accurate operating order of the controller at the control center and to control many dome cameras. The address code is made up of SW3 (8 bits) on PCB board.
  • Page 7 With reference to the above chart: When all code switches are under “OFF” status on VPTZ500, address code is 1. When you input Numerical key No.1 on VKB300/VKB200 control keyboard, then press CAM key for confirmation showing that set VKB300/VKB200 address as No.1 control address., At this time, VKB300/VKB200 keyboard can control VPTZ500 dome camera(its control address is 0001).
  • Page 8 Baud Rate Options: 1200BIT/S 、2400BIT/S 、4800BIT/s、9600BIT/s 3.1.4 RS-485 Bus Matching Resistance For central controlling, the matching resistance should be set for the device that is furthest away from the controller. There is an end matching resistance switch on SW2. The 8 bit of SW2 shows ON status (see chart below) which means the BUS matching resistance has been connected.
  • Page 9: Installation Preparation

    Check for all necessary materials, and ensure if the selected installation location is suitable for the VPTZ500. 3.2.2 VPTZ500 Indoor Hemisphere Dome Camera Recessed Installation VPTZ500 Installation ATTN: Installation locations should endure five times the total weight of the camera assembly (dome camera, mounting bracket and mounting base) to avoid in shaken images.
  • Page 10: Housing Installation

    · Housing Installation A Take out the housing from the carton, adjust the thickness of bolt reed more than that of ceiling. B Stick 3 ring to housing, and install the upper housing in the round hole of the ceiling, connecting flange edge with the ceiling surface closely.
  • Page 11 Connection (Outer Connecting Wire) Connect BNC video interface of dome camera with video wire (BNC) which is finished installing. Connect power supply line with power line (AC24V) which have been set well. Electricity Check the polarity of the plug and outlet, then check all connecting wires. Domes enter self-inspection, and make a horizontal 360°...
  • Page 12: Setting And Adjusting Preset Position

    IV. VKB300/VKB200 Keyboard Control Use Instruction to VPTZ500 Dome Camera Use the VKB300 keyboard controller to realize the complete potential of the VPTZ500 intelligent speed dome. (The VKB300 keyboard control protocol is set as the default protocol for the VPTZ500.) 4.1Setting and Adjusting Preset Position...
  • Page 13: Dome Pattern Tours

    It can set a running speed at each preset position from 0.4/s to 280/s (1-64grades) and dwell time from (1-60seconds). Note: VPTZ500 can rotate at low speeds and at fast speeds. Its speed can be divided into 64 grades. 1 is the lowest speed and 64 is the fastest speed.
  • Page 14 1. In the Main Menu, Press the FUN key once. VKB300/200 Keyboard displays: Press CLR to delete previous data. Input required VPTZ500 address code XXXX (1 1024)for control Press Enter for 2. Enter the correct Speed Dome Unit and Press Enter.
  • Page 15 Input 10, press Enter 4.2.2 Pattern Tours Setting VKB300/200 keyboard can set pattern tour groups for the VPTZ500 speed dome camera. Before setting the Pattern Tours please set all preset positions in advance. If the preset positions are not set the pattern tour will default to the pattern tour parameter.
  • Page 16: Points Scan

    Two pattern tours styles can be used: A .To-and-from scanning 1-2-…………..-16-1-2-……….-16-1-……….. Make an auto circle scanning by points. Press EXIT key and exit to default status of the keyboard. Input cruise No adjust key SCAM into to-and-from scanning B. Cruise scanning 1-2-………-15-16-15-………-2-1-2-……..-15-16-15-…Make an auto cruise scanning Press EXIT key and exit to default status of the keyboard.
  • Page 17: Guard Location

    1. Move the joystick to desired position. 2. Input the running speed (1-64) and then input Shift + AUTO key. Note: When VPTZ500 dome camera is under the auto scanning status, you can use the joystick if you want it to stop scanning.
  • Page 18: Objective Tracking

    When manually adjusting the zoom length or focal distance at longer ranges, a typical PTZ dome may move too quickly resulting in the loss of important images. The VPTZ500 is especially designed to adjust the sensitivity of the Pan and Tilt controls making navigation easy and intuitive at these long ranges.
  • Page 19 Objects that are too dark or faint 4.6.3 Iris Control The VPTZ500’s default setting is for auto-adjust iris. It can make an adjustment quickly through auto detecting the beam change. User can adjust iris size manually through control keyboard to get required image brightness.
  • Page 20 Example: Dome Address XXXX052, VKB300/200 keyboard displays: Use MON key(Page up)and SEQ page down to select camera OSD. Press Ack key (confirmation), LIST (Select). 01. PELCO-D、 PELCO-P protocol: Adjust preset position:No.55 and enter menu. Please refer to VI (next page). 02.
  • Page 21 For example: Use VKB300/VKB200 keyboard to control VPTZ500 speed dome PELCO protocol. Set the protocol, address and baud rate to VPTZ500 dome camera, make it same as that of the keyboard. When Input 51, then input CALL, the dome will make the slow scanning between two points. If input 51, then input SHIFT+CALL, will enter starting point of line scanning(i.e.
  • Page 22: Exception Handling

    VII Exception Handling Issue Possible Reason Solution Power on, no movement, Power line connected wrong Correct it no image, indicator light Power damaged Replace does not light Blowout Replace Power line be connected bad Check it Power on, self check, has The machine’s address code or Reset image, can’t control,...
  • Page 23 inary System Code ncoder Address inary System Code ncoder Address inary System Code ncoder Address 0010101 0101011 1000001 01000010 01101100 10010110 01000011 01101101 10010111 01000100 01101110 10011000 01000101 01101111 10011001 01000110 01110000 10011010 01000111 01110001 10011011 01001000 01110010 10011100 01001001 01110011 10011101 01001010...
  • Page 24 11010001 11100111 11111100 11010010 11101000 11111101 11010011 11101001 11111110 11010100 11101010 11111111 11010101 IX. VPTZ500 Dome Camera Spare Parts List Parts Quantity Unit Manual and Operating Instructions Operating Sketch Map Screwdriver Screw M8*12 Screw M3*8 Glove Camera Module Housing Dome...

Table of Contents