Bar Graph; Battery Indicator; Frequency Shifting - First Texas Products Teknetics T2 Operating Manual

Professional metal detector guide to metal detecting
Hide thumbs Also See for Teknetics T2:
Table of Contents

Advertisement

LCD VISUAL DISPLAY (continued)
BAR GRAPHS Fe
This bar graph displays the magnetic mineralization factor, or magnetic susceptibility, of the soil.
Magnetic susceptibility is expressed in terms of the percent volume of the iron mineral magnetite,
which most black sand is made of. The depth to which objects can be accurately identified is
strongly influenced by the magnetic susceptibility of the soil. High Fe
effect on detection depth in the Discrimination mode than in the All Metal mode. For the most
accurate Fe
O
reading, pump the searchcoil as though you were ground canceling.
3
4
Fe
O
approx.
3
4
Range
micro-cgs
3
1
0.3
0.1
0.03
0.01
blank
BATTERY CONDITION INDICATOR
Fresh alkaline batteries will illuminate all four bars. When no bars are displayed and the
batteries are about to go dead, the BATT legend will start flashing. If using NiMH rechargeable
batteries, the display will remain stuck on the second or third bar for most of the battery life;
when it drops to the first bar, the batteries will go dead within several minutes.

FREQUENCY SHIFTING

One disadvantage of a highly sensitive metal detector is its susceptibility to electrical
interference from other electronic devices. If the detector chatters while the searchcoil is not in
motion, the cause is either electrical interference or internal circuit noise due to a high
sensitivity setting. If the detector chatters or emits intermittent false signals in the field, you are
also probably experiencing electrical interference. If you suspect electrical interference, you
may change the T
2
's operating frequency. This is a trial and error method to try to find a
frequency different from the suspected source.
To shift frequencies:
1. Hold the MENU button down. Do not release the button.
2. Push the trigger forward to increase the frequency
Or pull the trigger back to decrease the frequency.
Each frequency change requires a push of the MENU
button.
Each actuation will shift the frequency by one value.
The LCD will display the frequency, from F1 to F7. The
default frequency is F4. The T
the power is switched off.
See page 26 for more information on electrical interference.
Comprehensive Operating Manual & Guide to Metal Detecting
O
(magnetite)
3
4
Description
7,500
uncommon but not rare, heavy mineralization
2,500
heavy mineralization, not uncommon in goldfields
750
heavy mineralization, but not uncommon in some regions
250
medium mineralization, typical
75
light mineralization, but common
25
light mineralization, often low G.C. setting
<14
quartz & coral white beach sands
2
will default back to F4 when
TEKNETICS
O
values have a greater
3
4
21

Advertisement

Table of Contents
loading

Table of Contents