Download Print this page

Ring Powering PowerSource RINV1000 User Manual

Powersource pro converts low voltage

Advertisement

Quick Links

Protective features
Low battery alarm - An alarm will sound when the voltage from the battery drops to 10.5 volts DC. This indicates
that the battery the PowerSource is connected to will require recharging. (If connected to a vehicle battery,
starting the vehicle engine should be sufficient) The Powersource will automatically shutdown if its voltage is
allowed to drop to 9.5 volts DC or below.
Over voltage protection - The PowerSource will automatically shutdown if the input voltage exceeds 15 volts DC.
Reverse polarity protection - Reverse polarity (incorrect battery connection) may result in the blowing of the
internal blade fuses. If this occurs immediately, disconnect the battery. The internal blade fuses will need to be
checked by a qualified electrician if the PowerSource does not continue to work.
Overload protection - The PowerSource will automatically shut down if the continuous power draw exceeds its
maximum rating of the PowerSource.
Temperature protection - If the temperature of the internal heat sink reaches >65oC the Powersource will shut
down automatically. Allow the PowerSource to cool before using again.
Troubleshooting guide
Problem
Possible Cause
Low output voltage
PowerSource is overloaded
Low battery alarm on all the time
Inadequate power or excessive voltage drop
Poor battery condition
No Power output
PowerSource not fully warmed up
Internal fuses have blown
PowerSource in thermal shutdown condition
Low battery voltage
Specifications
PowerSource Model
1
Max. Continuous power (Watts)
/
hour only
2
Continuous Power
Peak Power (Watts) 0.01 Seconds
Standby current (AMPS)
Waveform
Modified sine wave
Efficiency Ω
Approximately 90 %
Input Voltage Range
AC Socket
Fuse
Ω Percentage of battery power converted to mains voltage power.
'e' & 'CE' approved
Distributed by:
Ring Automotive Gelderd Road, Leeds LS12 6NB
Tel: +44 (0)113 276 7676 Fax: +44 (0)113 231 0266
Email: autosales@ring.ltd.uk
Suggested Remedy
Reduce load, not exceeding maximum rating
Check connections from battery
to PowerSource
Replace battery
Turn the PowerSource switch on and off
repeatedly until the appliance has started.
Fuse replacement (qualified electrician only)
Allow to cool (10 Minutes)
Charge or replace battery
RINV1000
RINV2000
1000w
2000w
800w
1600w
2000w
4000w
< 0.5A
< 0.8A
Modified sine wave
Approximately 90 %
10v – 15v DC
10v – 15v DC
3 Pin mains
3 Pin mains
30 amps (x 4)
30 amps (x 8)
4
PowerSourcePro
L209
User Manual
RINV1000
RINV2000

Advertisement

loading

Summary of Contents for Ring Powering PowerSource RINV1000

  • Page 1 Inadequate power or excessive voltage drop Check connections from battery to PowerSource Poor battery condition Replace battery RINV1000 No Power output PowerSource not fully warmed up Turn the PowerSource switch on and off repeatedly until the appliance has started. RINV2000...
  • Page 2 RINV1000 power supply and provides 230-240v AC current. Switch off the RINV1000 PowerSource. The RINV1000 PowerSource comes complete with x 1 positive connecting Special attention should be made to ‘Caution’ statements in this user manual. cable and x 1 negative connecting cable that are to be connected onto the back of the PowerSource using the ‘Caution’...

This manual is also suitable for: