As an option a VoIP (SIP based) plug-in module can be installed, which will give 2x RJ-11 analogue phone connections. The CPE is provisioned via DHCP/TFTP, however also SNMP can be used to for surveillance and settings. Following DKTCOMEGA product codes are supported: ...
The boot process of the CPE node The boot process is split in two: First the node issue a dhcp request with dhcp option 60 set to <file name>vx_xx (where x_xx is the version number of the firmware). Afterwards the node start it's operation system (OS). The OS also issue a dhcp request, with dhcp option 60 set to the version of the software.
Page 5
Also telnet daemon must be started, with the use of telnetd -l /bin/sh command in the script DKTCOMEGA Fanoevej 6 DK-4060 Kirke Saaby +45 4646 2626 CPE User Guide v_04_07 Page - 5 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
DHCP Settings The CPE requires a dhcp server connected to the fiber WAN port before power on. As an example we have used Linux Kubunto platform and installed the following component via adept dhcp3 tftpd Make sure that DHCP server has its unique static IP address settings, so it doesn’t conflict with its own leasing of IP Addresses.
Page 7
3) CPE requests in its LINUX Boot-up process, where configuration file is requested: Option: 53, 61, 60, 50, 54, 55, 1, 3, 28, 66, 67 To edit DHCP Server Setup for dhcp3, edit the DHCP setup configuration file: sudo kate /etc/dhcp3/dhcpd.conf...
Page 8
2_00 and forward ---# --------------- END OF UPGRADE ------------------- # The following is needed in order for the CPE to download the configuration. Remember to place this configuration file in TFTPBOOT directory. Remember to assign correct eth interface, subnet/mask, IP address range, TFTP-server name and bootfile-name below subnet <Subnet>...
TFTP Settings After the DHCP server is configured a TFTP server should be configured, so firmware image and configuration file for the CPE can be downloaded correctly. As an example we have used Linux tftpd and xinetd The TFTP configuration file must be edited. And a tftpboot directory must be...
Page 10
# CONFIGURATION FILE SECTION: insert the following socket_type = dgram wait = yes user = nobody server = /usr/sbin/in.tftpd server_args = /tftpboot disable = no DKTCOMEGA Fanoevej 6 DK-4060 Kirke Saaby +45 4646 2626 CPE User Guide v_04_07 Page - 10 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
DK-4060 Kirke Saaby Please notice that text editors using Carrier Return for each line is NOT supported. The text editor should use Line Feed for line separation. +45 4646 2626 CPE User Guide v_04_07 Page - 11 +45 4646 2625 mail@dktcomega.com...
Page 12
# port=3, bucket=0, rate=1000kb/S, bytecounter=layer3,limitaction=flowcontrol switch --port-map-to-pirl-bucket 4:0 # join port 4 to bucket 0. Please notice that thisfeature is NOT valid for the Gigabit CPE #Downlink rate (Total for WAN 2Mbps) switch --set-port-ingress-rate-limit 0:1:2000:3:FC # port=0(WAN), bucket=0, rate=2Mb/S, bytecounter=layer3,...
Device script commands The following commands are supported in the script that will be downloaded to the CPE via TFTP during boot-up process. This command is used to configure the switch in the unit. The command takes one or more of the following parameters, with the syntax...
--enable-port-flowcontrol=PORT:(1|0) Enables/disables flow control on the port --get-enable-port-flowcontrol=PORT:(1|0) Prints the status of flow control on the port DKTCOMEGA Fanoevej 6 Rate control: DK-4060 Kirke Saaby +45 4646 2626 CPE User Guide v_04_07 Page - 14 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
Page 15
This makes IEEE tags to used priority to IP4/IP4 fields if both exists. --get-port-map-rule=PORT DKTCOMEGA Prints the status of if IEEE tags is prioritized over IP4/IP4 fields Fanoevej 6 if both exists. DK-4060 Kirke Saaby +45 4646 2626 CPE User Guide v_04_07 Page - 15 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
Page 16
Prints the status of blocking untagged frames DKTCOMEGA # Note from firmware revision earlier than 02_05 Fanoevej 6 --add-vtu-entry=VID:WAN:LAN1:LAN2:LAN3:LAN4:CPU:NRL-ENABLE DK-4060 Kirke Saaby Adds an entry to the VTU table. +45 4646 2626 CPE User Guide v_04_07 Page - 16 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
Page 17
IEEE 802.1Q for the port, fallback mode DKTCOMEGA 2=check, enables IEEE 802.1Q for the port, check mode Fanoevej 6 3=secure, enables IEEE 802.1Q for the port, secure mode DK-4060 Kirke Saaby +45 4646 2626 CPE User Guide v_04_07 Page - 17 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
Page 18
Flushes all counter for a single port. --get-port-rmon-counters=PORT, Prints the RMON counters for a port. DHCP Option 82: supported from firmware revision 03_00 and later, in the 794xx series (1 GbE CPE). --set-port-dhcp-option82=PORT:enable[:<optional text>] (1Gb) Enable or disable DHCP option 82 (DHCP relay agent).
When the traffic egress the LAN port the vlan tag is removed. The syntax for the command is: DKTCOMEGA Fanoevej 6 DK-4060 Kirke Saaby +45 4646 2626 CPE User Guide v_04_07 Page - 19 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
Page 20
211 is tagged ingress on both WAN and LAN port 1, whereas VLAN 221 is tagged ingress on WAN and untagged ingress on LAN port 1. All other ports are not member of the VLANs. A management VLAN 951 is defined (untagged), which enables communication between system operator and CPE for management purposes (untagged). DKTCOMEGA...
VLAN from other IEEE 802.1Q VLANs in a hierarchical fashion that is compatible Fanoevej 6 DK-4060 Kirke Saaby with IEEE 802.1Q aware switches. This method places an extra or Double Tag in +45 4646 2626 CPE User Guide v_04_07 Page - 21 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
The LAN ports are disabled per default. Therefore the configuration file should DKTCOMEGA enable the LAN ports by issuing the command: Fanoevej 6 DK-4060 Kirke Saaby +45 4646 2626 CPE User Guide v_04_07 Page - 22 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
The device supports IGMP snooping, and join messages received from clients on the LAN ports will be handled by the CPE CPU, which will control which ports that belongs to which multi cast group. IGMP snooping has to be enabled per port but is...
Page 24
In some cases race conditions can occur, if the CPE filter times out before a client has responded to an IGMP query, hence signal will be lost, as CPE expect that the client is no longer member of the multicast group.
Known multicasts, MC # this should be used only if you know the multicast traffic, must be present in the ATU DKTCOMEGA Please note that Gigabit CPE doesn’t support a multi port bucket based structure, as ingress rate limitation Fanoevej 6 DK-4060 Kirke Saaby works at a port based level, so not more than one port can be associated with a bucket.
Page 26
# port=3, bucket=0, rate=1000kb/S, byte counter=layer3, limitation = drop switch --set-port-ingress-rate-limit 3:0:1000:3:DROP # join port 4 to bucket 0, Please notice that this feature is NOT valid for the Gigabit CPE switch --port-map-to-pirl-bucket 4:0 #Downlink rate (Total for WAN 2Mbps)
DKTCOMEGA Support for remote logging via syslog (RFC 3164) Fanoevej 6 DK-4060 Kirke Saaby To start syslog, enter the following line in your configuration file +45 4646 2626 CPE User Guide v_04_07 Page - 28 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
-> support -> firmware. These can be loaded into a standard MIB browser or 3 party SNMP management system. CATV setup DKTCOMEGA Fanoevej 6 DK-4060 Kirke Saaby +45 4646 2626 CPE User Guide v_04_07 Page - 29 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
Same scenario can be made based on traffic type and/or Source/Destination MAC addresses DKTCOMEGA is recommending that CPU port always is granted high priority as it will ensure that management traffic is passed to the internal CPU on the device.
Page 31
--set-ip4ip6-queue-map=57:0 # DiffServ value of 57 will go to queue with lowest priority Fanoevej 6 switch --set-ip4ip6-queue-map=56:0 # DiffServ value of 56 will go to queue with lowest priority DK-4060 Kirke Saaby +45 4646 2626 CPE User Guide v_04_07 Page - 31 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
RAM memory, which means that the device would need to have Fanoevej 6 the configuration loaded at every boot. DK-4060 Kirke Saaby +45 4646 2626 CPE User Guide v_04_07 Page - 32 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
ID of a client, during any IP address allocation. When DHCP Option 82 is enabled on the CPE, it inserts the per port defined information into the DHCP packets as they pass through the CPE on their way to the DHCP server.
# combinations of the above is also possible /etc/init.d/lldpd start –CEF # Starts LLDP and CDP/EDP/Foundry DP on WAN port DKTCOMEGA Fanoevej 6 DK-4060 Kirke Saaby +45 4646 2626 CPE User Guide v_04_07 Page - 34 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
# Save configuration to flash memory, same SSH key is used at every boot save_configuration Now it is possible to log into the CPE as the user ”Administrator” (case sensitive) through SSH. ssh Administrator@<IP address> ssh -l Administrator <IP address>...
Page 36
SSH daemon is started. Procedure for changing SSH password on all CPE units. If password for Administrator is to be changed for all CPE's do the following: 1) Log into one CPE via ssh 2) change user to root with command su...
Page 37
# save configuration to flash memory, now the password is saved locally on each CPE DKTCOMEGA Fanoevej 6 DK-4060 Kirke Saaby +45 4646 2626 CPE User Guide v_04_07 Page - 37 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
"dkt2code_5_05_00.ece"; A bridge between the ATA and the CPE Linux has to be established. If the ATA has to be configured on a separate VLAN than for CPE management (untagged), the following command should be used:...
Web Interface Alternatively the ATA can be managed via HTTP browser by inserting http://<IP Address> User name: <to be disclosed by DKTCOMEGA> Password: <to be disclosed by DKTCOMEGA> System Parameters Generic settings for the ATA plug-in module can be configured under System ...
Fanoevej 6 Enable automatic reconnection on link loss (retains DK-4060 Kirke Saaby net isp reconnect on link loss initial configuration if disabled), CURRENTLY NOT IMPLEMENTED +45 4646 2626 CPE User Guide v_04_07 Page - 40 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
Page 41
Please notice that this can cause delays in making and receiving calls if the STUN service is not used, but enabled. +45 4646 2626 CPE User Guide v_04_07 Page - 41 +45 4646 2625 mail@dktcomega.com...
System Identification: DKTCOMEGA Parameter Description Default Fanoevej 6 DK-4060 Kirke Saaby (C) 1994-2009 ata copyright notice DKTCOMEGA’s copyright notice DKTCOMEGA +45 4646 2626 CPE User Guide v_04_07 Page - 42 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
Page 43
(as assigned) Unique device ID including Ethernet MAC used for net unique device id (as assigned) DHCP and update operations DKTCOMEGA Fanoevej 6 DK-4060 Kirke Saaby +45 4646 2626 CPE User Guide v_04_07 Page - 43 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
Default provider selection Fanoevej 6 DK-4060 Kirke Saaby Alternate provider to use when selected voip provider alternate provider is unavailable (0 to disable) +45 4646 2626 CPE User Guide v_04_07 Page - 44 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
User-Agent header for outbound responses if not DKTCOMEGA sip user agent DKTCOMEGA 3.27 empty Fanoevej 6 DK-4060 Kirke Saaby sip require user name Require username to match for incoming calls Disabled +45 4646 2626 CPE User Guide v_04_07 Page - 46 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
Page 47
6 Belcore-r6 pattern 6 Fanoevej 6 DK-4060 Kirke Saaby Telephone event name to produce distinctive ring sip distinctive ring names 7 Belcore-r7 pattern 7 +45 4646 2626 CPE User Guide v_04_07 Page - 47 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
Additional voice receive gain in dB units DKTCOMEGA Fanoevej 6 ipbx voice tx gain Additional voice transmit gain in dB units DK-4060 Kirke Saaby +45 4646 2626 CPE User Guide v_04_07 Page - 48 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
Page 49
Time in msec to delay hookflash action in case of ipbx hookflash delay hangup DKTCOMEGA Fanoevej 6 ipbx answer hangup delay Time in msec for answer side hangup delay DK-4060 Kirke Saaby +45 4646 2626 CPE User Guide v_04_07 Page - 49 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
represent the frequency (Hz) Fanoevej 6 tone_elementX_freq tone_elementX_db DK-4060 Kirke Saaby and signal level (dB) of each tone. A negative frequency is used to +45 4646 2626 CPE User Guide v_04_07 Page - 50 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
Page 53
(GR) SLAC receive gain in dB units DK-4060 Kirke Saaby slac port tx gain (GX) SLAC transmit gain in dB units +45 4646 2626 CPE User Guide v_04_07 Page - 53 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
Enables customer use of block last caller service Enabled ipbx three way calling service Enables customer use of three way calling service Enabled DKTCOMEGA Fanoevej 6 DK-4060 Kirke Saaby +45 4646 2626 CPE User Guide v_04_07 Page - 56 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
2 regardless of whether the second call was incoming or not (i.e. hookflashing will switch between the two active calls). +45 4646 2626 CPE User Guide v_04_07 Page - 57 +45 4646 2625 mail@dktcomega.com...
Hot/warm dial string (empty) DKTCOMEGA Fanoevej 6 Sets the SLAC line polarity during dialing (forward ipbx polarity dialing Forward DK-4060 Kirke Saaby or reverse) +45 4646 2626 CPE User Guide v_04_07 Page - 58 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
Page 59
"[]" selection group of candidate digits DKTCOMEGA Fanoevej 6 DK-4060 Kirke Saaby "[^]" exclusion group of digits +45 4646 2626 CPE User Guide v_04_07 Page - 59 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
Page 60
VoIP provider “area code.” Recognize a “**” DK-4060 Kirke Saaby string starting with , and proceeding with any of the digits 1-9. defines “**” “e#” +45 4646 2626 CPE User Guide v_04_07 Page - 60 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
Page 61
After that point, the ATA continues to collect digits until the user pauses two seconds. Then the ATA sends the dialed string to the service provider. DKTCOMEGA Fanoevej 6 DK-4060 Kirke Saaby +45 4646 2626 CPE User Guide v_04_07 Page - 61 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
The default TFTP server is the same as used for the CPE configuration file. Note when Wifi is installed, LAN port 4 of the CPE switch is used as dedicated Wifi port. All VLAN and QoS parameters related to LAN port 4 must be configured AFTER the “enable_wifi”...
Page 67
IGMP functionality, Enable or Disable igmpEnabled DKTCOMEGA Fanoevej 6 NAT functionality, Enable or Disable natEnabled DK-4060 Kirke Saaby IP based port filtering, Enable or Disable IPPortFilterEnable +45 4646 2626 CPE User Guide v_04_07 Page - 67 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
Page 68
B/G protection technology is CTS-To-Self. It will try to reserve the BGProtection throughput for 11bg clients association. TxAntenna RxAntenna DKTCOMEGA Fanoevej 6 0: long preamble, 1: Short preamble TxPreamble DK-4060 Kirke Saaby +45 4646 2626 CPE User Guide v_04_07 Page - 68 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
Page 69
0;0;0;0 VLANPriority VLAN priority WscConfMode WPS function, bitwise. DKTCOMEGA WscConfStatus It shows the current status of the WPS process. Fanoevej 6 DK-4060 Kirke Saaby WscAKMP +45 4646 2626 CPE User Guide v_04_07 Page - 69 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
Page 70
11n performance parameter. Enable it if needed. HT_LinkAdapt Applicable to HT Physical Mode HT_OpMode Applicable to HT Physical Mode DKTCOMEGA Fanoevej 6 DK-4060 Kirke Saaby HT_MpduDensity Applicable to HT Physical Mode +45 4646 2626 CPE User Guide v_04_07 Page - 70 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
Page 71
Input the port of the Radius server. The default port is 1812. 1812 RADIUS_Key DKTCOMEGA;DK TCOMEGA;DKTC DKTCOMEGA Authentication Key OMEGA;DKTCOM Fanoevej 6 DK-4060 Kirke Saaby +45 4646 2626 CPE User Guide v_04_07 Page - 71 +45 4646 2625 mail@dktcomega.com www.dktcomega.com...
Appendix 1 – ATA configuration file Please notice that the ATA supports provisioning of the configuration file in both clear text as well as in encrypted format. Default is clear text, if encrypted format is preferred, please consult DKTCOMEGA for further details. # Accounts ata_service_name&3c0=DKTCOMEGA ata_factory_name&300=Factory...
Need help?