6000 Series Table of Contents Overview .................. 1 Introduction ...................1 Unpacking and Checking ..............1 Front and Rear Panels ............2 Front Panel....................2 Rear Panel ....................5 Operation ................. 6 Pre-installation ..................6 Setting the Output Voltage and Output Current........6 Constant Voltage/Constant Current Characteristics ......7 Operation Modes...................7 3.4.1 Independent Mode..............7 3.4.2 Serial Tracking Mode..............8...
6000 Series Overview This 6000 Series Direct Current (DC) Power Supply Operation Manual contains an introduction to the power supply, a description of its functions, the operation procedure, the scope of applications and its specifications. The models available under this series are the 6302A, 6302AR, 6302D, 6302DR, 6303A, 6303AR, 6303D, 6303DR, 6306A, 6306AR, 6306D, 6306DR, 6603A, 6603AR, 6603D, and 6603DR.
6000 Series Front and Rear Panels Front Panels Front panel with digital display for models 6302D, 6302DR, 6303D, 6303DR, 6306D, 6306DR, 6603D and 6603DR...
Page 6
6000 Series Front panel with analog meter for models 6302A, 6302AR, 6303A, 6303AR, 6306A, 6306AR, 6603A and 6603AR Figure 1 Front Panels C.V. Mode LED: Uses green LED to indicate constant voltage at slave power Power Switch: Power ON/OFF switch (1=ON, 0 = OFF) C.C.
Page 7
6000 Series SLAVE Voltage Indicator Analog: As indicated by the pointer in the 40 x 40 mm (Class 2.5) meter Digital: Displayed in full 3-digit red 0.52" LED MASTER Voltage Indicator Analog: As indicated by the pointer on the 40 x 40 mm (Class 2.5) meter Digital: Displayed in full 3-digit red 0.52"...
6000 Series Rear Panel Figure 2 Rear Panel (26) Remote Control Function Switches: Only available on remote models. Refer to the Remote-Control Operation Manual for details. (27) D-Type 9-pin connector (RC1) for Remote Control (28) D-Type 9-pin connector (RC2) for Remote Control (29) Power Input Socket (30)
6000 Series Operation Pre-installation Before you turn on the power: • Check that the input voltage from your power source conforms to the voltage rating selected. Refer to the Input Power Fuse Holder and Input Voltage Selector in section 2.2. The tolerance is +10% of the indicated voltage at 50/60 Hz.
6000 Series Constant Voltage/Constant Current Characteristics This power supply can automatically operate between constant voltage and constant current by responding quickly to rapid load changes. The following figures shows the relative changes between the constant current and the constant voltage modes. Constant Voltage Crossover Point Output...
6000 Series 3.4.2 Serial Tracking Mode Under this mode, the - Master Output Terminal is automatically shorted with the + Slave Output Terminal. This serial output is generated from the + Master Output Terminal and the - Slave Output Terminal. The output voltage is twice the set master output voltage while the output current is the same as the master setting value.
6000 Series 3.4.3 Parallel Tracking Mode Under this mode, the - Master Output Terminal is shorted with the - Slave Output Terminal while the + Master Output Terminal is shorted with the + Slave Output Terminal automatically. This parallel output is generated from the + Master Output Terminal and the -Master Output Terminal (or - Slave Output Terminal).
6000 Series Fixed 5V/5A Output This is the standard 5V/5A power output for use by TTL logic circuits. When the load exceeds 5 amperes, the red OVERLOAD LED lights up. The following figures show the parallel-output connection method and its characteristic curve. OVER LOAD 5V5A LOAD...
6000 Series Serial Operation Serial connection is used to connect two or more power supplies in series to obtain a higher voltage ratings (maximum 240V for this power supply). Figure 7 shows the serial connection between two 6303D power supplies at series tracking. One unit is set at 60V/2A (MASTER setting is 30V/2A) while the other is at 40V/3A (MASTER setting is 20V/3A).
6000 Series Parallel Operation Parallel connection is used to connect two or more power supplies of the same model in parallel to obtain a higher current output (maximum 24A for this power supply). Figure 9 shows the parallel connection between two 6303D power supplies at parallel tracking. One unit is set at 30V/5A (MASTER setting is 30V/2.5A) while the other is at 20V/6A (MASTER setting is 20V/3A).
6000 Series Maintenance Changing the Fuse The fuse is located inside the input power fuse holder (refer to Figure 2). You need to change the fuse when: • the fuse is blown out • you change the voltage rating In any case, replace the fuse with one of the same rating. Refer to Table 1 for the type of fuse used for each model and voltage.
6000 Series Specifications Model 6302A 6303A 6306A 6603A 6302AR 6303AR 6306AR 6603AR Specification 6302D 6303D 6306D 6603D 6302DR 6303DR 6306DR 6603DR Output Voltage 0-30V x 2 0-30V x 2 0-30V x 2 0-60V x 2 0-30V x 2 0-30V x 2 0-30V x 2 0-60V x 2 Output Current 0-2A x 2 0-3A x 2...
Page 18
6000 Series Model 6302A 6303A 6306A 6603A 6302AR 6303AR 6306AR 6603AR Specification 6302D 6303D 6306D 6603D 6302DR 6303DR 6306DR 6603DR Output Voltage 0-30V x 2 0-30V x 2 0-30V x 2 0-60V x 2 0-30V x 2 0-30V x 2 0-30V x 2 0-60V x 2 Output Current 0-2A x 2 0-3A x 2...