Do you have a question about the GP-3360 and is the answer not in the manual?
Questions and answers
Summary of Contents for GEViCAM GP-3360
Page 1
GEViCAM OPERATIONS MANUAL GP-3360 GP-2360 GP-3780 GP-21400 GP-151400 GEViCAM Inc. A GigE Vision Camera Company Rev: Ver. A.0.6 Date: 4-10-08...
Page 2
The material contained in this manual consists of information that is proprietary to GEViCAM Inc. and may only be used by purchasers of the products. GEViCAM Inc. makes no warranty for the use of its product and assumes no responsibility for any errors which may appear or for damages resulting from the use of the infor- mation contained herein.
GEViCAM Inc Table of Contents Introduction Page Product Family Description Features and Benefits GigE Vision Standard Compliant Models System Configuration 1.4.1 Camera Power Requirement 1.4.1.1 GPIO Connector 1.4.1.2 RJ-45 Connector 1.4.2 PC Requirement 1.4.2.1 PC Basic Requirement 1.4.2.2 Network Adaptor 1.4.2.3 Ethernet Switch...
Page 4
GEViCAM Inc Table of contents (continue) Page 3.3.6 Strobe/ Internal Exposure Signal Output 3.3.7 Back-to-back Strobing 3.3.8 Multiple Frame Capture (ITS Mode) and Bracketing Exposure 3.3.9 Auto-iris Lens Application Mode Advanced Camera Functions (Hardware Description) 3.4.1 RS-485 Interface 3.4.1.1 RS-485 3.4.1.2 CAN Device Control...
Page 5
Save State to Flash Fig. 34 Grab Continuous Fig. 35 Image Saving, File format Fig. 36 PLC Main Block Fig. 37 GEViCAM PLC Block Fig. 38 Configuration, IP Engine Fig. 39 Signal Routing Block, I0 Fig. 40 Signal Routing Block, LUT Fig. 41 Enhanced Func.
Giga-bit Ethernet interface all together. In today’s many applications, which use full advantage of digital data for image capture, process and manipulation for the best result, the GigE technology excels the most. GEViCAM family is designed to serve for the demanding and vast applications.
The following switches have been suggested by Pleora. 3COM 3C1740x (3800 Family) 3C1770x (4900 Family) DLINK DGS-10xxTx 10/100/1000 Family DGS-3308-FG, DGS-3308-TG CISCO WS-C3750G-12S-S The above list may change from time to time. Please contact GEViCAM or Pleora for the updated models.
It is a good idea to bench-test the products prior to the field installation. GEViCAM cameras have highly integrated functions and do not need many add-ons. However, please check the product items and options or accessories if you ordered them.
GEViCAM Inc 2.2 Driver Installation 2.2.1 PC Software Use the Pleora Coyote Software to launch the High-performance Driver and GigE communication. For detailed installation of the High-performance Driver, please refer the Pleora’s instruction document. The Standard Ethernet Driver (Window Stack) has to be replaced with the High-performance Driver.
Page 10
GEViCAM Inc 2.2.2.2 Ver. 2.3.1 e-Bus Driver (Recommended) Install the GEViCAM SDK ver. 2.3.1. If you have the ver. 2.2.0 or older one installed, uninstall the driver at first and make sure iPort file of “Pleora Technologies” in the Program file is empty.
Easy Customization This is the very refined platform design and easy to build custom-design products out of these blocks. The blocks of Imager, Signal and GPIO boards are easily customized. Memory Block Please contact GEViCAM for the specific requirement. Fig. 12...
Click “address” and “OK”. The IP addresses appear in the Connection dialog box. • On “Camera”, click “Select camera”. GEViCAM cameras are designed to take the standard Pleora “camera link camera”. Click “OK”. Then click “Apply”. The IP Engine Setting infor- Fig.
Page 13
GEViCAM Inc 3.2.2 Configure and Camera Control Firstly, open “Configuration Advanced” and set up the correct image size and pixel information from each tab. Next, select “Port Communication” tab. The port is “Serial Port 0” for this camera control. Se- lect two locations of “Hexadecimal”...
3.3.2.1 12-bit, 10-bit, 8-bit Linear Output (PixelDepth): (00 00 00 00, - 01, -02) The GEViCAM platform has a 12-bit high speed A/D converter and the output is selectable of 12, 10 and 8-bit (Factory Default: 8-bit). Both 10 and 8-bit conversions are done by taking the most significant bits out of the 12 bit.
(00 21 00 00 00 01). GEViCAM has the no-delay reset capability to reset both horizontal and vertical without internal sync delay. Only a few fixed pixel-clock delays (4 clocks typical) exist as the internal logic delay. The data output delay occurs through the signal process but it is not the trigger or reset delay.
GEViCAM Inc 3.3.4.2 Pulse-width Exposure Control This is selected as Async Pulse-width Control in trigger mode (00 23, 00 00 00 02). The pulse width between the falling (leading) edge and the rising (trailing) edge is the exact period of the exposure.
GEViCAM Inc 3.3.7 Back-to-back Strobing: (00 23 00 00 00 03), (00 25) Two consecutive strobes per one trigger are output with a programmable interval before and after the CCD transfer gate. Thus two frame images of strobe lightings at very short interval can be captured.
GEViCAM Inc 3.4.1.2 CAN Device Control CAN (Controller Area Network) is slightly different serial bus using the same technology as RS-485. As option, we can mount CAN device instead of RS-485 transceiver. CAN protocol must be provided by user. W1 GND Video 3.4.2 Opto-isolated I/O...
4.3 Functions and Features There are numbers of benefits to go to GigE cameras in many applications. • Pleora engine: GEViCAM uses industry-leading Pleora Technologies’ engine, core and SDK. Many organizations worldwide support the SDK as well as Pleora’s support group. •...
Link but signal and data format follow Camera Link definition). Therefore, the Coyote application software calls for “Standard Camera Link” as the GEViCAM connection. (Fig. 24) In order to operate the frame grabber functions, the camera and PC must be connected, the proper driver and Coyote Application soft-ware need to be installed.
GEViCAM Inc 4.4.3 Port Control (Serial Port Control for Camera Functions) Camera control is done in similar way as Camera Link serial control. There are 3 separate serial ports and the camera control is using the Serial Port 0. The GP-series control is register-base architecture in 16-bit address followed by 32-bit data.
GEViCAM Inc 4.4.4 Color Camera The difference between monochrome and color camera is the CCD with monochrome or RGB Bayer pattern. The camera data outputs are the same for both but for the color camera, the PC software interpolation makes the color reproduction into RGB.
GEViCAM Inc 4.5 Image Capture and Save The image capture is controlled in the “Acquisition” tab. The typical mode is “Grab Continuous”. Since the camera side only outputs FVAL (Frame Valid) Pulse per trigger, the frame grabber side can stay in continuous mode and only grabs images when it receives FVAL for Async Trigger.
GEViCAM Inc 4.6 GPIO (Programmable Logic Controller) 4.6.1 Programmable Logic Controller Functions 4.6.1.1 PLC Main Block The Pleora core has a very powerful GPIO control, which replaces simple PLC (Programmable Logic Controller) in factory automation floor. In other words, a GigE camera can replace a camera, a frame grabber and a PLC to save the cost and space.
GEViCAM Inc 4.6.1.2 Configuring PLC Functions In order to configure the PLC (GPIO) functions, let’s start the GP-series operation at first. Open the Coyote Application and click “Configure”. The PLC configuration is in the “IP Engine” tab. With the advanced configuration marked, there are 5 segments of PLC configuration blocks.
GEViCAM Inc 4.6.1.5 Programming Pulse Generator You have two ways to program the Pulse Gen- erator. You can go to; • Enhanced Function Block One method is to program Pulse Generator #0. Internal Trigger needs the falling edge trigger and make sure the Trigger mode is “Falling edge”.
GEViCAM Inc 4.6.1.6 Enhanced Function Block Connections The Inputs and outputs of the Enhanced Function Block are fixed as shown in Fig. 44. If you are feeding a signal into Pulse Generator 0, the output must go to Q9. For example, I1 with PLC Control Bit 0 is connected to the Pulse Generator 0, then the LUT is Q9=I1.
Page 28
GEViCAM Inc • Single Pulse Trigger with Pulse-width Control: Open the “IP Engine” tab and select “Signal Routing Block and Lookup Table”. (Fig. 46) Choose; I0: Pulse Generator 0 I1: PLC Control Bit 0. In the LUT, type Q0=I0, Q9=I1.
Page 29
GEViCAM Inc • Including Delayer: We can add delays into the trigger pulse after sending Set value command (Fig. 49). Let’s describe the PLC signal pass. PLC_CTRL0 Delayer Pulse Gen#1 Pulse Gen#0 For Signal Routing Block (Fig. 50) I0: Pulse Generator 0 Output...
GEViCAM Inc 4.6.1.8 Other Programmable Logic Controller Functions There are many useful tools for PLC in the real world factory automation. The GP-series’ default has one input and one output opto-isolators. These IOs can be used for the trigger input instead of TTL in noisy environment, and the output can be used for an ejector after counting number of triggers (use General Purpose Counter).
GEViCAM Inc 4.6.3 GPIO Input and Output • TTL Input and Output The Trigger Input and Strobe/Exposure Control Pulse Out are TTL input and output. The simplified input and output circuits are shown in Fig. 57. It is a typical high-speed inverter-buffer IO and the sink current is not high (24 mA).
If you have older files, rename them prior to copying the new update. (4) Power up the GEViCAM camera with current program and make sure the camera is connected to the PC through Ethernet. Open Coyote Launcher application and setup the communication as usual.
Page 35
GEViCAM Inc 8.2 Mechanical (Unit: mm) Fig. 59 GPIO Connector Pin Assignment> < 12V RTN (GND) 8 Power in 12V 9 Trigger in (TTL) Strobe out 10 RS-485 - RS-485 + 11 Opto D1 in - Opto D1 in +...
Page 36
GEViCAM Inc 9. Pleora Document Lists The documents listed here are included in the Pleora SDK software ver. 2.3.0. These are helpful tools to supplement this manual. When you unzip and install the SDK software, it contains a docu- mentation file among other Pleora Technologies files in the Program file of your computer.
Page 37
GEViCAM Inc Signal Handling GPIO Control Block GPIO Control Block Programming Inputs TTL Inputs Optically Isolated Input Camera Inputs LVDS Inputs Software GPIO Control Bits Pulse generators Rescaler Delayer Counter Timestamp Triggers Feedback Inputs Outputs TTL Outputs Optically Isolated Output...
GEViCAM Inc Troubleshooting Guide 9.7.1 Scope 9.7.2 Installation Issues 9.7.2.1 Can’t install the iPort SDK 9.7.2.2 Pro/1000 Grabber Device (High performance driver) is missing in Device Manager. 9.7.2.3 Window could not find a match or the hardware in the specified file.
Page 40
GEViCAM A GigE Vision Camera Company 1698 Yosemite Drive Milpitas, CA 95035 U.S.A. Tel:408-262-5772 Fax:408-262-0962 Email:info@gevicam.com Web site: www.gevicam.com GEViCAM Inc. GP Series Manual Version: A.0.6 Date: 4-10-08...
Need help?
Do you have a question about the GP-3360 and is the answer not in the manual?
Questions and answers