STRIKE FIRST SF-PW250 Service Manual

Water – hand portable stored pressure fire extinguishers

Advertisement

STRIKE FIRST
CORPORATION
STORED PRESSURE FIRE EXTINGUISHERS
DO NOT USE THIS EXTINGUISHER ON CLASS C (ENERGIZE ELECTRICAL EQUIPMENT),
B (FLAMMABLE LIQUIDS) OR D FIRES.
PROTECT FROM FREEZING TEMPERATURES
All fire extinguishers should be installed, inspected & maintained in accordance with the National Fire Protection Association (NFPA) 10,
2007 Edition "Standard for Portable Fire Extinguishers" and the local authorities having jurisdiction.
When installation, inspection or maintenance is required, Strike First Corporation strongly recommends the work to be performed by
NFPA 10 (2007) certified personnel. Fire extinguishers are pressure vessels and must be treated with respect and handled with care.
They are mechanical devices and require periodic maintenance to be sure that they are ready to operate properly and safely.
Strike First Corporation makes O.E.M. parts available to insure proper maintenance. Substituting O.E.M. parts voids the Strike First
warranty, as well as the UL & ULC Listings. DO NOT SUBSTITUTE.
Strike First Corporation does not service, maintain or recharge fire extinguishers. This manual is published as a guide to assist qualified
service personnel in the inspection, maintenance and recharge of Strike First fire extinguishers only. This service manual should be
used in conjunction with the appropriate Parts Lists/Pictograms for each unit being serviced. No service manual can anticipate
all the possible malfunctions that may be encountered in the service of fire extinguishers. Due to the possibility that prior service
performed on this equipment may have been improperly done, it is extremely important that all warnings, cautions and notes in this
manual be carefully observed. Failure to heed these instructions could result in serious injury.
Strike First Corporation assumes no liability for service, maintenance or recharge of fire extinguishers by publishing this service manual.
For installation instructions of Strike First portable fire extinguishers please refer to all of the following:
1.
Owner's Manual - included with the unit
2.
NFPA 10 "Standard for Portable Fire Extinguishers – 2007 Edition
3.
Local authorities having jurisdiction
For operation instructions on Strike First portable fire extinguishers please refer to one or all of the following:
1.
Fire Extinguisher Nameplate/Label
2.
Owner's Manual – included with the unit
3.
NFPA 10 "Standard for Portable Fire Extinguishers – 2007 Edition
4.
Your local authorized Strike First Distributor
WARNING:
ALWAYS WEAR EYE PROTECTION WHEN SERVICING PRESSURIZED FIRE EXTINGUSIHERS.
CAUTION:
PERSONS EXPECTED TO USE THIS FIRE EXTINGUISHER SHOULD BE TRAINED IN INITIATING ITS
OPERATION AND IN THE PROPER FIRE FIGHTING TECHNIQUE.
RECHARGE FIRE EXTINGUISHERS IMMEDIATELY AFTER ANY USE
SERVICE MANUAL
UL / ULC
WATER – HAND PORTABLE
Model: SF-PW250 / WBDL-PW250
WARNING
1
H
(v1)
O
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SF-PW250 and is the answer not in the manual?

Questions and answers

Summary of Contents for STRIKE FIRST SF-PW250

  • Page 1 UL & ULC Listings. DO NOT SUBSTITUTE. Strike First Corporation does not service, maintain or recharge fire extinguishers. This manual is published as a guide to assist qualified service personnel in the inspection, maintenance and recharge of Strike First fire extinguishers only. This service manual should be used in conjunction with the appropriate Parts Lists/Pictograms for each unit being serviced.
  • Page 2 Maintenance, servicing & recharging shall be performed by trained and certified persons having available the appropriate servicing manual, the proper types of tools, recharge materials, lubricants, and Strike First O.E.M. replacement parts. Fire extinguishers shall be subjected to maintenance at intervals of not more than 1 year, at the time of hydrostatic test, or when specifically indicated by an inspection.
  • Page 3 Check hose assembly and nozzle for dirt, sediment or obstruction. Clean and replace parts as necessary. 6. Defect in the cylinder* Contact a Strike First dealer if under warranty, otherwise – mark “CONDEMNED” and remove from service or return to owner.
  • Page 4 STRIKE FIRST CORPORATION (“STRIKE FIRST”) warrants its fire extinguishers (“Products”) to be free from defects in material and workmanship for a period of six (6) years from the date of manufacture. Strike First’s responsibility for defects in material or workmanship are limited to repair or replacement of the products for the original retail purchaser (“Consumer”) only.
  • Page 5 STRIKE FIRST CORPORATION SERVICE MANUAL: PART No. C250700 WATER 2.4 Gallon (9L) UL/ULC Rating: 2A Models: SF-PW250 & WBDL-PW250 ITEM # PART # DESCRIPTION C160210 Hose Band W162690 Water Hose Assembly Cylinder W163700 Siphon Tube Assembly W160600 Wall Hook W163650...

This manual is also suitable for:

Wbdl-pw250

Table of Contents