HearthRite HR06MN-1 Owner's Operation And Installation Manual

HearthRite HR06MN-1 Owner's Operation And Installation Manual

Infrared vent-free natural gas space heater

Advertisement

OWNER ' S OPERATION AND INSTALLATION MANUAL
HR06MN-1 HR10MN-1 HR10TN-1

Table of Contents

Important Safety Information.................................2
Product Features.....................................................3
Proper Ventilation & Fresh Air..............................4
Installation................................................................6
Operating Your Heater............................................10
Cleaning & Maintenance.......................................13
Trouble Shooting...................................................14
Specifications..........................................................17
Parts List..................................................................19
Warranty Information...........................................24
WARNING: If the information in this
manual is not followed exactly, a f i r e o r
e x p l o s i o n m a y r e s u l t causing property
damage, personal injury, or loss of life.
WARNING: This is an unvented gas-
fired heater. It uses air (oxygen) f r o m t h e
r o o m i n w h i c h i t i s installed. Provi-
sions for adequate combustion and ventila-
tion air must b e p r o v i d e d . R e f e r t o A i r
F o r Combustion and Ventilation section on
page 4 of this manual.
A Division of Empire Comfort Systems,Inc.
918 Freeburg Avenue
Belleville,IL 62220
Phone : 618-233-7420 or 1-800-851-3153
Fax : 618-233-7097 or 1-800-443-8648
www.hearthrite.com
Do not store, or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately
call
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed by a
q u a l i f i e d
i n s t a l l e r , s e r v i c e
supplier.
WA R N I N G :
adjustment, alteration, service or mainte-
nance can cause injury or property damage.
Refer to this manual for correct installation and
operational procedures. For assistance or
additional information consult a qualified
installer, service agency, or gas supplier.
This appliance may be installed in an aftermar-
ket*
permanently
(mobile) home, where not prohibited by local
codes.
This appliance is only for use with the type of
gas indicated on the rating plate. This
appliance is not convertible for use with other
gases.
WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM
HEATERS
Water vapor is a by-product of gas combustion.An
unvented room heater productes approximately one (1)
ounce (30ml) of water for every 1,000 BTU's (.3KW's) of
gas input per hour. Refer to page 3.
*Aftermarket: Completion of sale, not for purpose of
resale, from the manufacturer.
Installer: Please leave these instructions with the
consumer.
Consumer: Please retain these instructions for
future use.
INFRARED VENT-FREE
NATURAL GAS
SPACE HEATER
your gas supplier from a
a g e n c y
I m p r o p e r
i n s t a l l a t i o n ,
located, manufactured
o r
g a s

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HR06MN-1 and is the answer not in the manual?

Questions and answers

Summary of Contents for HearthRite HR06MN-1

  • Page 1: Table Of Contents

    If you cannot reach your gas supplier, call the fire department. HR06MN-1 HR10MN-1 HR10TN-1 Installation and service must be performed by a q u a l i f i e d i n s t a l l e r , s e r v i c e...
  • Page 2: Important Safety Information

    IMPORTANT Always run heater with control Keep the appliance area clear SAFETY INFORMATION knob at ON, LOW or HIGH a n d f r e e f r o m c o m b u s t i b l e locked positions.
  • Page 3: Product Features

    PRODUCT FEATURES Control LOCAL CODES Knob Install and use heater with care. Follow all local Ignitor codes. In the absence of local codes, use the Button latest edition of National Fuel Gas Code ANSZ223.1 , also known as NFPA 54*. *Available from : American National Standards Institute, Inc.
  • Page 4: Proper Ventilation & Fresh Air

    Unusually Tight Construction Confined and FRESH AIR FOR The air that leaks around doors and Unconfined Space COMBUSTION AND windows may provide enough fresh The National Fuel Gas Code VENTILATION air for combustion and ventilation. ANS Z223.1 defines a confined However, in buildings of unusually space as a space whose volume WARNING: This heater...
  • Page 5: Air For Combustion And Ventilation

    3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free heater Btu/Hr Example: Gas water heater* Btu/Hr Gas water heater 40,000 Btu/Hr Gas furnace Btu/Hr Vent free heater 10,000 Btu/Hr Vented gas heater Btu/Hr total 50,000 Btu/Hr Gas Fireplace logs Btu/Hr Other gas appliances* +...
  • Page 6: Installation

    VENTILATION AIR Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts: You must provide two permanent openings: one " within 12 of the ceiling and one within " of the floor. Connect these items directly to the outdoors or spaces open to the outdoors.
  • Page 7 INSTALLATION Attaching to Wall Anchor: This Removing Lower Front Panel Of WARNING: Maintain the method allows to attach Heater minimum clearances shown mounting bracket to hollow walls 1. Remove two screws near F i g u r e 4 . y o u c a n , (wall areas between studs) or to bottom corners of lower front...
  • Page 8 INSTALLATION Installing Bottom Mounting Attaching Mounting Bracket To Screws Wall 1. Locate bottom mounting hole. This Note: Wall anchors, mounting hole is near bottom on back screws, and spacers are in panel of heater (see Figure 11). hardware package. The hardware 2.
  • Page 9 INSTALLATION CONNECTING TO GAS SUPPLY WARNING: A qualified service person must connect heater to gas supply. Follow all local codes. WARNING: This appliance " requires a 3/8 NPT (National Pipe Thread) inlet connection to the pressure regulator. WARNING: Never connect heater to private (non-utility) gas well.
  • Page 10: Operating Your Heater

    INSTALLATION OPERATING YOUR HEATER CHECKING GAS Pressure Testing Heater Gas FOR YOUR SAFETY CONNECTIONS Connections READ BEFORE LIGHTING 1. Open equipment shutoff valve WARNING: Test all gas piping WARNING: If you do not (see Figure 13). and connections for leaks after follow these instructions exactly, 2.
  • Page 11 OPERATING YOUR HEATER Manual Control Models TO SELECT LIGHTING HR06MN HEATING LEVEL INSTRUCTIONS STOP! Read safety WARNING: When running information on the side of h e a t e r , s e t c o n t r o l k n o b heater.
  • Page 12 OPERATING YOUR HEATER THERMOSTAT MODEL 4. Wait five(5) minutes to clear HR10TN out any gas. Then smell for gas, including near the floor. If you FOR YOUR SAFETY “ ” smell gas, STOP! Follow in the READ BEFORE LIGHTING safety information on the side of WARNING: If you do not follow Figure 20 - Control Knob In The heater.
  • Page 13: Cleaning & Maintenance

    OPERATING HEATER Continued BURNER FLAME PATTERN ODS/PILOT AND BURNER Figure 25 shows a correct burner Use a vacuum cleaner, pres- MANUAL LIGHTING surized air, or a small, soft flame pattern. Figure 26 shows an PROCEDURE bristled brush to clean. incorrect burner flame pattern. Remove lower front panel (see CLEANING BURNER Figure 7 page 7).
  • Page 14: Troubleshooting

    TROUBLESHOOTING Note : troubleshooting CAUTION: Never use a wire, WARNING: Only a qualified items are listed in order of service person should service and needle, or similar object to clean operation. repair heater. ODS/pilot. This can damage ODS/pilot unit. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When ignitor button is pressed and...
  • Page 15: Troubleshooting

    TROUBLESHOOTING Continued POSSIBLE CAUSE REMEDY OBSERVED PROBLEM 1. Burner orifice is clogged. 1. Clean burner orifice (see Cleaning B u r n e r ( s ) d o e s n o t l i g h t a f t e r and Maintenance, Page 13) or ODS/pilot is lit.
  • Page 16 TROUBLESHOOTING Continued WARNING: If you smell gas Shut off gas supply. Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • Page 17: Specifications

    If they are unable to supply original replacement part(s), call the num- ber on the front of this manual. When contacting your dealer or HearthRite, have ready: your name your address model...
  • Page 18 ILLUSTRATED PARTS BREAKDOWN HR06MN...
  • Page 19: Parts List

    PARTS LIST This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page17 of this HR06MN manual. PART NUMBER DESCRIPTION Cabinet Assembly MB10008E MB09003E Lower Front Panel Assembly Reflector Unit ML006-02E Burner Assembly MB19007...
  • Page 20 ILLUSTRATED PARTS BREAKDOWN HR10MN...
  • Page 21 PARTS LIST This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 17 of this HR10MN manual. PART DESCRIPTION NUMBER Cabinet Assembly MB10008E Lower Front Panel Assembly MB09003E Reflector Unit ML006-01E Burner Assembly MB19005...
  • Page 22 ILLUSTRATED PARTS BREAKDOWN HR10TN...
  • Page 23: Part List

    PART LIST This list contains replaceable parts for your heater. When ordering replacement HR10TN parts, follow the instructions listed under Replacement Parts on page 17 of this manual. PART DESCRIPTION NUMBER MB10007E Cabinet Assembly Lower Front Panel Assembly MB09003E ML006-01E Reflector Unit MB19005 Burner Assembly...

This manual is also suitable for:

Hr10mn-1Hr10tn-1

Table of Contents