Operating Instructions for the Palm LDB Version 1.40 Table of Contents General Method of Operation................ 2 System Requirements ................... 2 Installing the PalmLDB .................. 3 Starting Actions ..................... 4 Exporting the Locking Plan to the Palm ............7 Editing Lockings .................... 9 Reimporting Data From the Palm to the PC..........15...
Operating Instructions for the Palm LDB Version 1.40 General Method of Operation With the Palm Organizer (versions: Palm m5xx, Tungsten W and Tungsten T3) and the PalmCD2 programming device, you can very conveniently and easily program and read out your System 3060 digital lockings.
Operating Instructions for the Palm LDB Version 1.40 Installing the PalmLDB Before you install the PalmLDB, you must install the Palm Organizer Software and carry out a HotSync. If an older PalmLDB version is installed on the Palm, you must delete it first.
Operating Instructions for the Palm LDB Version 1.40 Do this by touching PalmLDB PalmLDB-Info in the menu bar. If an older software version (< PalmLDB1.40) is installed, please contact your dealer or SimonsVoss directly. Make sure that the LDB that you are using matches the respective PalmLDB.
Page 5
Operating Instructions for the Palm LDB Version 1.40 Carry out Emergency Opening Touch the Open door button. Then enter the locking system password (for LSM: the user password) on the keyboard shown in the display. Pay attention to upper and lower case letters – the password is case-sensitive. Then touch Testing the PalmCD2 Touch the ConfigDevice button.
Page 6
Operating Instructions for the Palm LDB Version 1.40 Reading out an Unknown Locking Touch Edit lockings and then Read. You will see the following information: • ID numbers of the locking system and locking • Battery status of the locking •...
Operating Instructions for the Palm LDB Version 1.40 Exporting the Locking Plan to the Palm Open your locking plan on the PC and make any changes that are necessary. Then authorize the locking plan and transponder programming. Select File Export Palm databases.
Page 8
Operating Instructions for the Palm LDB Version 1.40 Now indicate the Palm user for whom the locking plan is to be exported and whether you want to end HotSync manager automatically after transmission. last setting is important if you subsequently...
Operating Instructions for the Palm LDB Version 1.40 Edit Lockings In the PalmLDB, touch Edit lockings and then Enter. Enter the file password on the keyboard shown in the display. Pay attention to upper and lower case letters – the password is case-sensitive.
Page 10
Operating Instructions for the Palm LDB Version 1.40 If you do not want to display the transponder names, deactivate the control box by touching determine whether Palm communicating with the corresponding locking via the PalmCD2, you can select the "Acoustic acknowledges"...
Page 11
Operating Instructions for the Palm LDB Version 1.40 Access and Transponder Lists Touch the appropriate button. ☺ If you have already read a locking's access or transponder list and you touch one of the associated buttons again, you will be asked if you want to read the list out again or if you would like to display the saved version.
Page 12
Operating Instructions for the Palm LDB Version 1.40 You will see a list of authorized transponders, which are marked with an X, and blocked transponders. Mark the appropriate transponder. Then you can authorize or block the transponder. The locking will be programmed when you select the appropriate key.
Page 13
Operating Instructions for the Palm LDB Version 1.40 Choosing Lockings Here you will see a list of all lockings in a locking system and information as to which lockings need to be programmed (Sync). The "Yes" behind the locking description means that the locking still needs to be programmed.
Page 14
Operating Instructions for the Palm LDB Version 1.40 Replacing a Digital Locking When you replace a locking that cannot be reset, the software cannot program the new locking at first. First you have to reset this locking in the locking plan: Select the appropriate locking and touch Details.
Operating Instructions for the Palm LDB Version 1.40 Reimporting Data From the Palm to the PC After you have finished programming or reading out the components, you must transfer the data from the Palm back to the PC. Do this by placing the Palm in the docking station.
Operating Instructions for the Palm LDB Version 1.40 If you use the same serial interface for the ConfigDevice and the HotSync station, conflicts can arise in the communication. You can remedy this problem as follows: Deactivate the serial interface in the locking plan software on the PC (Options Comport) before each HotSync process.
Need help?
Do you have a question about the Palm LDB Version 1.40 and is the answer not in the manual?
Questions and answers