Storage; Servicing - Outdoor Leisure PMSQSS40 Owner's Manual

Propane/lp patio heater
Table of Contents

Advertisement

Available languages

Available languages

1. Allow at least 45 minutes for heater to cool
down after using.
2. Store heater upright in a sheltered area
away from inclement weather and dust.
3. If desired, cover heater after heater has
cooled.
To assure safety, proper function and lon-
gevity of the heater, regular maintenance is
required. The frequency of maintenance will
depend on the usage of the unit. Review the
following concerning the criteria for a properly
functioning heater. Failing to follow proper,
regular maintenance will void warranty.
A hazardous condition may result if a heater
is used that has been modified or is not func-
tioning properly. When the heater is working
properly:
• The flame is contained within the heater.
• The flame is essentially blue with perhaps
some yellow tipping.
• There is no strong disagreeable odor, eye
burning or other physical discomfort.
123748-01A

STOragE

4. If heater is not to be used for an extended
period of time, disconnect and remove
propane/LP gas cylinder and store in ac-
cordance with the Standard for Storage
and Handling of Liquefied Petroleum
Gases, ANSI/INFPA 58.

SErvicing

• There is no smoke or soot internal or ex-
ternal to the heater.
• There are no unplanned or unexplained
shut downs of the heater.
The parts list shows the heater as it was con-
structed. Do not use a heater which is different
from that shown. In this regard, use only the
hose, regulator and cylinder connection fitting
(called a POL fitting) supplied with the heater.
IMPORTANT: Do not use alternates. For this
heater, the regulator must be set as shown
in Specifications, page 2. If there is any un-
certainty about the regulator setting, have it
checked by a qualified service person.
www.desatech.com
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pmsqw40Pmsqhb40

Table of Contents